Dear Customer,  

 

Thank you for purchasing the product of the company UNIS COOL s.r.o., which is long-time successful manufacturer and 
supplier of a specialized range of professional refrigeration and catering equipment. We believe that with the help of this 

facility you will attract a lot of attention to the exhibited goods and your guests will be happy to return. 
 

 
 

 Symbols used in this manual

 

 
 

SYMBOL 

MEANING 

 

These symbols are the "

WARNING

" and "

CAUTION

" and point to the fact that the activity can cause 

damage and / or serious injury to the user. 

 

 

This symbol indicates an important instruction, property, process or matter, which is necessary during the 
servicing and maintenance of equipment comply or be aware of. 

 

Symbol points to useful information related to the device or accessories. 

 

Symbol is a reference to another section of this manual. 

 

 
 

 For whom is the guidance intended 

 
This  manual  is  intended  for  all  persons  who  come  into  contact  with  the  device  during  the  installation,  operation  and 

maintenance. Each of these persons must be thoroughly familiar with its content before beginning any activity with the 
device. 

 
 

 Necessary notice 

 
Carefully follow the instructions therein, to make the use of equipment, but also ensure its optimum use and long life.  

 

Do  not  turn-on  the  unit  until  you  are  thoroughly  familiar  with  all  instructions,  restrictions  and 

recommendations that are included in this manual, especially the chapter "Safety in use".  

 

The illustrations used in this manual may not always agree with reality; their purpose is to describe the main principles of 
the device. 

 
 

 If you are unsure 

 
In practice there are often unpredictable situations that can not be included in this instruction and described. Therefore, 

whenever you are not sure, contact your supplier.  
 

When contacting the supplier or trained technician, please prepare the basic data about the device.  
 

You can read the nameplate, located in the upper right corner of the enclosure cooling units, see the last page. 
 

 
 

 
 
 

 
 

 
 

 

Summary of Contents for KENTUCKY COLD GN1

Page 1: ...Refrigerated top table counter KENTUCKY COLD Operating manual...

Page 2: ...dance intended This manual is intended for all persons who come into contact with the device during the installation operation and maintenance Each of these persons must be thoroughly familiar with it...

Page 3: ...must be stored under the following conditions 1 Showcase should be kept in their original packaging in a dry and dark place 2 Do not turn upside down nor to side the showcase Do not place any objects...

Page 4: ...from such an activities the equipment manufacturer is not liable the risk is covered by the user solely Before first run please read the chapters 3 3 and 3 4 carefuly follow the steps noted there to...

Page 5: ...OPERATING MANUAL FOR KENTUCKY COLD 3 2 4 Dimensions KENTUCKY COLD GN1 KENTUCKY COLD GN2 KENTUCKY COLD GN3 KENTUCKY COLD GN4...

Page 6: ...OPERATING MANUAL FOR KENTUCKY COLD 4 KENTUCKY COLD 600 KENTUCKY COLD GN2 High KENTUCKY COLD GN3 High More of technical information can be found in Chapter 9...

Page 7: ...ssing or the guide is unclear contact your supplier 1 Showcase should be aligned to the horizontal position by using the adjustable feets on the bottom of the display case Align the showcase by turnin...

Page 8: ...shelves may lead to fall and cause injury 4 2 While using the showcase If the device is damaged in any way turn it off immediately unplug it from the power supply and contact your supplier Operate th...

Page 9: ...OPERATING MANUAL FOR KENTUCKY COLD 7 5 OPERATION 5 1 Control panel The control panel consists of 1 electronic control unit 2 light switch 3 main On Off...

Page 10: ...ress button The set value is displayed for about 15 seconds Increasing the temperature Press the button to get required value Press and realease the button to save it Decreasing the temperature Press...

Page 11: ...ial maintenance However it must be kept clean and remove the residues of exhibited goods and other contaminants Instructions for maintenance are obligatory to follow otherwise void the warranty Just r...

Page 12: ...showcase dries up completely to prevent mold and unwanted odors 6 2 Weekly maintenance Disconnect the showcase from power supply Empty showcase and let it reach room temperature Clean entire inner sp...

Page 13: ...r depending on the installation site It occurs when there is high humidity of the ambient air and water from the air coming into contact with cold surfaces This is normal In this case wipe with a dry...

Page 14: ...the procedure under Art 8 REGULATION OF THE EUROPEAN PARLIAMENT AND COUNCIL REGULATION EU No 517 2014 Components better be disposed of at the site which is specialized and thus will be possible to re...

Page 15: ...Temperature C 2 6 2 6 2 6 2 6 Voltage V Hz 230 50 230 50 230 50 230 50 Power W 290 330 480 650 Consumption kWh 24h 11 62 Weight kg 56 0 74 0 95 0 121 0 GN2 High GN3 High Atyp 600 Dimensions mm 750 x...