OVERVIEW

The SulfiLogger™ sensor is available in a number of different configurations. Some of these are available in
ATEX certified versions. Pay close attention to your product type during the reading of this manual and the

installation of the sensor. ATEX certified versions of the sensor are labeled SulfiLogger™ X1 and standard
versions of the sensor are labeled SulfiLogger™ S1. If your product is an ATEX certified product (X1 series
sensors) it is very important that you carefully follow the instructions related to ATEX specific installation
requirements. Guidance for installation of the SulfiLogger™ sensor can be found in Appendix A. This guide
is relevant for sensors with serial numbers starting from S/N: 1004000. For older sensors please find the
relevant guide on the SulfiLogger™ website at www.sulfilogger.com or contact Unisense.

3

Summary of Contents for SULFILOGGER

Page 1: ...SulfiLogger_Manual_EN_203 pdf SulfiLogger User Manual COPYRIGHT 2019 UNISENSE A S VALID FOR SERIAL NUMBERS FROM S N 1004000 REV 2019 11 19...

Page 2: ...leaning 4 Calibration 4 Operating principles 5 Electrochemical measurements of hydrogen sulfide 5 Measuring in different media unit conversions 5 Specifications 6 SulfiLogger sensors 6 Technical speci...

Page 3: ...ut of the use the results of use or the inability to use this product Unisense A S assumes no liability for damages on instruments designed for indoor use due to unintended field use or exposure to du...

Page 4: ...ulfiLogger X1 series sensors only EX Pay close attention to other EX equipment used in conjunction with the SulfiLogger sensor Observe the specifications in the certificate as well as national and loc...

Page 5: ...fiLogger X1 and standard versions of the sensor are labeled SulfiLogger S1 If your product is an ATEX certified product X1 series sensors it is very important that you carefully follow the instruction...

Page 6: ...lled using a flow cell please detach the sensor from the flow cell before starting the calibration If needed replace the O ring on the sensor before re installation 1 2 3 4 5 6 SUCCESS FAILURE 6 1000...

Page 7: ...of the daily variations in ventilation conditions in the head space of the sewer and it is independent of the exact mounting position of the sensor in the liquid the sulfide concentration is fairly ho...

Page 8: ...t 1 of full range Operating humidity range 0 100 Design temperature range 20 C to 60 C 4 F to 140 F Operating temperature range 0 C to 40 C 32 F to 104 F MECHANICAL SPECIFICATIONS Length 240 mm Diamet...

Page 9: ...lose to the end of pipe of the force main as possible to get a realistic measure of the initial H2S concentration The SulfiLogger S1 X1 1120 5mgL sensor can be mounted at access points directly on the...

Page 10: ...hould be stated on the bottle or can be provided by the vendor If judging the accuracy of the SulfiLogger sensor based on liquid phase measurements there are various ways to do this all of which are p...

Page 11: ...Logger sensor is temperature compensated the accuracy of the sensor is highest if the calibration is done at a temperature close to the temperature of subsequent measurements Problem During a calibrat...

Page 12: ...highly toxic gas and special precautions are needed to avoid the risk of injury or death Furthermore the installa tion of the SulfiLogger sensor in applica tions such as sewer networks or other facil...

Page 13: ...he Sul fiLogger sensor and ensure that the pressure pipe system does not exceed the pressure limit Bypass flow using a flow cell A portion of the flow can be di rected bypassed into a flow cell on whi...

Page 14: ...SulfiLogger_Manual_EN_203 pdf UNISENSE UNISENSE DENMARK www unisense com info unisense com...

Reviews: