5. OPERATION INSTRUCTIONS 

5-1. Precaution 

1) AC input 
  AC input must be within the range of line voltage ±10%, 50/60Hz. 

 

WARNING. 

To avoid electrical shock, the power cord protective grounding conductor must be 

connected to ground. 

 
2) Installation 
Avoid using the supply in a place where the ambient temperature exceeds 40

Allow enough space around the power supply for ventilation. 

 

WARNING.

 To avoid damaging the power supply, do not use it in a place where ambient 

temperature exceeds 40

 

WARNING.

 Voltages more than 60V DC are a lethal shock hazard to the user. Be careful when 

connecting power supplies to achieve voltages higher than 60V DC total or 60V DC between 
any connection and earth ground. 

              Operation mode: single or tracking (serial or parallel) operation (two units). 
 

 

CAUTION. 

1 The instrument must be operated under rated main supply. If it is meant to work for a long 

time, it is suggested to use 60-70% instead of full load so as to avoid rapid aging.   

2. Avoid frequent short-circuit operations. 
3. In case of the instrument with full load, do not turn on the instrument. Before adding load, 

adjust the voltage knob to the minimum value, then turn on the instrument. Next turn the 
voltage/current adjustment knob to set targeted values. 

 
3) Output voltage overshoot 
Voltage between output terminals may exceed the present value when the power is turned on or off. 
 

5-2. Setting Current Limit

 

1) Determine the maximum safe current for the device to be powered. 
2) Temporarily short the positive “+” negative “-” terminals of the power supply together with a test lead. But 

for TP-2303TK/2305TK/30102/60052, just pushing the output ON/OFF key can make the short circuit 
function. 

3) Rotate the COARSE VOLTAGE control away from zero sufficiently for the CC indicator to light. 
4) Adjust the CURRENT control for the targeted current limit. Read the current value on the ammeter. 
5) The current limit (over load protection) has now been preset. Do not change the CURRENT control setting 

after this step. 

6) Remove the short between the “+” and “-” terminals and hook up for constant voltage operation. 
 

5-3. Constant Voltage/Constant Current Characteristic

 

The working characteristic of this series Power Supplies is called a constant voltage/constant current automatic 
crossover type. This permits continuous transition from constant current to constant voltage modes in response 

Summary of Contents for PS-303DU

Page 1: ...Multi channel DC Power Supply PS 303DU 305DU 3010DU 6005DU PS 2303 2305 Operation Manual V1 0 BENCHTOP INSTRUMENT...

Page 2: ...ear Panel Control 8 5 OPERATION INSTRUCTIONS 9 5 1 Precaution 9 5 2 Setting Current Limit 9 5 3 Constant Voltage Constant Current Characteristic 9 5 4 Operation Mode 10 5 4 1 Independent Operation 10...

Page 3: ...at the maximum output current or can be continuously adjusted throughout the output range The front panel current controls can be used to establish the output current limit overload or shout circuit...

Page 4: ...05DU 0 60V x2 0 5A x2 Built in 16 Dimensions PS 3010DU 6005DU 255Wx155Hx460D mm PS 303DU 305DU 2303 2305 255Wx155Hx330D mm 3 SPECIFICATIONS 3 1 Operation Mode 1 Independent Two independent outputs and...

Page 5: ...0mV Fixed output Output voltage 5V 0 25V Output current 3A Load regulation 25mV 110 220VAC rated input Ripple noise 2mVrms 5Hz 1MHz Display Voltmeter 3 digits 0 4 LED display Ammeter 3 digits 0 4 LED...

Page 6: ...4 Fig 4 2 b PS 2303 2305 Front panel Fig 4 2 c PS 3010DU 6005DU Front panel...

Page 7: ...5 Fig 4 3 d PS 303DU 305DU Rear panel Fig 4 4 e PS 2303 2305 Rear panel...

Page 8: ...6 Fig 4 5 f PS 3010DU 6005DU Rear panel Fig 4 6...

Page 9: ...when the MASTER supply is in the constant current operation 13 C C indicator Lights when the SLAVE supply is in the constant current operation Also lights when the TRACKING PARALLEL mode is selected 1...

Page 10: ...tput terminal for 5V supply 24 Output terminal Negative polarity output terminal for 5V supply 29 Output indicator Lights when switch is engaged in 30 Output ON OFF switch DC power supply output when...

Page 11: ...efore adding load adjust the voltage knob to the minimum value then turn on the instrument Next turn the voltage current adjustment knob to set targeted values 3 Output voltage overshoot Voltage betwe...

Page 12: ...ry will place a heavy load on the supply and it will operate in the constant current mode which may be adjusted for a 1 amp charging rate As the battery becomes charged and its voltage approaches 13 8...

Page 13: ...double the displayed value For example if the MASTER display is set for voltage metering and the SLAVE display for current metering the output voltage across the MASTER positive red terminal and the S...

Page 14: ...nly the MASTER output terminals are used for parallel tracking operation In the parallel tracking mode the SLAVE supply output voltage and current are tracking the MASTER supply output voltage and cur...

Page 15: ...correct this situation the load on the supply must be decreased so that no more than 3 amps of current are sucked 6 MAINTENANCE WARNING The following instructions are for use by qualified personnel on...

Page 16: ...Make sure the power cord is unplugged 2 Change the AC select switch to the desired line voltage position 3 A change in line voltage may also require a corresponding change of fuse value Install the c...

Reviews: