3. Adjust the
LIQUID
and
AIR
flow control valves until the
desired spray pattern is obtained. If necessary, adjust the
air and fluid pressure as well. Lock the needle valves in
place by turning the jam nut clockwise until tight.
4. Repeat for each nozzle.
Note:
Too much atomizing air flow will cause excessive
mist and result in an undesirable fog.
Using the Unist SPR-2000
™
or SPR-2000 JR
™
controller
or the customer supplied controller, the valves will need
to be programmed to cycle at the appropriate time for the
necessary duration to satisfy the application. Consult the
SPR-2000
™
or SPR-2000 JR
™
manual for further details.
Adjust The System For Pressure Drops
1. Depending on the system configuration, having
multiple nozzles operating at once can cause a pressure
drop across the valve stack in both the air and the fluid.
To account for this, simulate the anticipated drop by
turning on as many nozzles as you anticipate would be
on at any one time in your operation. If the spray nozzles
are no longer giving spray pattern set in step 3, increase
the incoming air and fluid pressure at the controller’s
or fluid supply regulator until they are once again
giving the desired spray pattern.
Ensure Fluid Is Connected
1. Open the
LIQUID
needle valve on the nozzle body
(4210 series)
or the valve stack
(4230 series)
by turning
the needle valve 1 full turn counter-clockwise. Actuate
the solenoid valve and wait for the fluid to fill the
tubing and for a steady stream to come out of the nozzle.
Depending on fluid pressure, fluid viscosity and tubing
length, this can take a minute or more.
a. If no fluid appears, refer to the Troubleshooting:
Fluid not coming out of nozzle section of this manual
(page 9).
3. Close the
LIQUID
needle valve.
4. Repeat for each nozzle.
Adjust The Spray Pattern
1. For each nozzle on the stack
(4210 series)
turn the
AIR
needle valve on the side of the nozzle body 1/2 turn
counter-clockwise to open it.
(4230 series)
Turn
the
Atomize
needle valve on the top of the solenoid
valve attached to the nozzle 1/2 turn counter-clockwise
to open it.
2. Place a piece of cardboard or other absorbent material
in the spot that will be sprayed. Actuate the valve for 1-2
seconds and check the spray pattern.
Startup & Operation
Figure 33: Opening the LIQUID needle valve (4210)
Figure 34: Opening the Liquid needle valve (4230)
Figure 35: Adjusting spray pattern
Figure 36: Adjusting spray pattern