Deluxe Media Air Cleaners
Model 1625 & 2025
READ INSTRUCTIONS BEFORE BEGINNING INSTALLATION
Safety and Installation Manual
Model 1625 & 2025 Deluxe Media Air Cleaner
WARNING
120/220 Volts may cause serious injury from electrical
shock.
Disconnect power to the furnace/air conditioner before
starting installation.
Sharp edges may cause injury from cuts.
Use care when
cutting and handling sheet metal.
CAUTION
To prevent component failure, do not install the air
cleaner on the warm air supply or in an area where
the temperature may exceed 180°F. This may include
areas above heat exchangers in downflow furnaces or
above exhaust flues in lowboy furnace cold air returns.
IMPORTANT
• The Model 1625 and 2025 Deluxe Media Air Cleaners are designed for systems with airflow up to 2000 cfm. Follow the furnace
manufacturer’s recommendations for the number of return air plenums and install one Model 1625/2025 Deluxe Media Air Cleaner
in each.
• The air cleaner can be installed horizontally, vertically or at an angle depending on furnace type. See
Figures 1, 2, 3 and 4
on
reverse side for orientation with various types of applications. Note airflow direction arrows on inner assembly and outer housing.
• Allow 29” clearance in front of Model 1625 and 26” in front of Model 2025 for media replacement.
•
Figure 5
shows the dimensions for both air cleaners. If a transition duct is required, see
Figure 4
for recommended duct angles.