268894-UIM-A-0407
18
Unitary Products Group
Ventilated Combustion Air
The ventilated attic space or a crawl space from which the combustion
air is taken must comply with the requirements specified in “AIR
SOURCE FROM OUTDOORS” in this instruction or in Section 5.3, Air
for Combustion and Ventilation of the National Fuel Gas Code, ANSI
Z223.1 (latest edition). This type installation requires two (2) properly
sized pipes. One brings combustion air from a properly ventilated attic
space or crawl space and a second pipe that extends from the furnace
vent connection (top right of unit) to the exterior of the building. Follow
all notes, procedures and required materials in the SEALED COMBUS-
TION AIR SUPPLY section in these instructions when installing the
combustion air pipe from the unit and into a ventilated attic space or
crawl space. DO NOT terminate vent pipe in an attic or crawl space.
Vent and Supply (Outside) Air Safety Check Procedure
For Category I furnaces, vent installations shall be in accordance with
Parts 7 and 11 of the National Fuel Gas Code, ANSI Z223.1/NFPA 54,
and or Section 7 and Appendix B of the CSA B149.1, Natural Gas and
Propane Installation Codes, the local building codes, furnace and vent
manufacturer's instructions.
FIGURE 24:
Horizontal Air Inlet, Outlet and Chimney Connections
TABLE 10:
Unconfined Space Minimum Area in Square Inch
BTUH Input Rating
Minimum Free Area in Square Inches
Required for Each Opening
(50 ft.
3
/ 1000 BTUH)
40,000
40 (258 cm
2
)
60,000
60 (387 cm
2
)
80,000
80 (516 cm
2
)
100,000
100 (645 cm
2
)
115,000
115 (742 cm
2
)
130,000
130 (838 cm
2
)
FURNACE
W
A
TER
HEA
TER
OUTLET
AIR DUCT
INLET
AIR DUCT
TABLE 11:
Free Area
Combined
BTUH Input
Rating For
All Appliances
Minimum Free Area Required for Each Opening
Horizontal Duct
(2,000 BTUH /
Sq. In.)
Vertical Duct or
Opening to Outside
(4,000 BTUH /
Sq. In.)
Round Duct
(4,000 BTUH /
Sq. In.)
40,000
20 in
2
(129 cm
2
)
10 in
2
(64 cm
2
)
4” (10 cm)
60,000
30 in
2
(193 cm
2
)
15 in
2
(97 cm
2
)
5” (13 cm)
80,000
40 in
2
(258 cm
2
)
20 in
2
(129 cm
2
)
5” (13 cm)
100,000
50 in
2
(322 cm
2
)
25 in
2
(161 cm
2
)
6” (15 cm)
150,000
60 in
2
(387 cm
2
)
30 in
2
(193 cm
2
)
7” (18 cm)
130,000
65 in
2
(419 cm
2
)
33 in
2
(213 cm
2
)
7” (18 cm)
EXAMPLE: Determining Free Area - Vertical Minimum Duct Size
Appliance 1 Appliance 2 Total Input
100,000
+ 30,000 = 130,000
÷
4,000 = 32.5 Sq. In.
EXAMPLE: Determining Free Area - Horizontal Minimum Duct Size
Appliance 1 Appliance 2 Total Input
100,000
+ 30,000 = 130,000
÷
2,000 = 65 Sq. In.
When a Category I furnace is removed or replaced, the original
venting system may no longer be correctly sized to properly vent
the attached appliances.
An improperly sized vent system can cause CARBON MONOXIDE
to spill into the living space causing personal injury, and or death.
FIGURE 25:
Outside and Ambient Combustion Air
GABLE
VENT
GAS
VENT
SOFFIT
VENT
VENTILATED
ATTIC
TOP ABOVE
INSULATION
OPTIONAL
INLET (a)
OUTLET
AIR (a)
VENTILATED
CRAWL SPACE
GAS
WATER
HEATER
VENTILATED
ATTIC
TOP ABOVE
INSULATION
GAS
VENT
GABLE
VENT
SOFFIT
VENT
GAS
WATER
HEATER
INLET
AIR (a)
INLET
AIR (b)
GAS
VENT
OUTLET
AIR (a)
OUTLET
AIR (b)
INLET
AIR (a)
INLET
AIR (b)
GAS
WATER
HEATER
FURNACE
FURNACE
FURNACE
1. An opening ma
y
be used in lieu of a duct to provide to provide the outside air
suppl
y
to an appliance unless otherwise permitted b
y
the authorit
y
having
jurisdiction. The opening shall be located within 12” (30.5 cm) horizontall
y
from,
the burner level of the appliance. Refer to “COMBUSTION AIR SOURCE FROM
OUTDOORS and VENT AND SUPPLY AIR SAFETY CHECK” in these
instructions for additional information and safet
y
check procedure.
2. The duct shall be either metal, or a material meeting the class 1
requirements of CAN4-S110 Standard for Air Ducts.
3. The duct shall be least the same cross-sectional area as the free
area of the air suppl
y
inlet opening to which it connects.
4. The duct shall terminate within 12 in (30.5 cm) above, and
within 24 in (61 cm) horizontall
y
from, the burner level of
the appliance having the largest input.
5. A square or rectangular shaped duct shall onl
y
be used
when the required free area of the suppl
y
opening is
9 in (58.06 cm ) or larger. When a square or rectangular
duct is used, its small dimensionshall not be less than
3 in (7.6 cm).
2
2
6. An air inlet suppl
y
from outdoors shall be equipped with
a means to prevent the direct entr
y
of rain and wind.
Such means shall not reduce the required free area of
the air suppl
y
opening.
7.
An air suppl
y
inlet opening from the outdoors shall
be located not less than 12” (30.5 cm) above the
outside grade level.
AIR SUPPLY OPENINGS AND DUCTS
COMBUSTION AIR SOURCE FROM OUTDOORS
1. Two permanent openings, one within 12 in (30.5 mm) of the top and
one within 12 in (30.5 mm) of bottom of the confined space,
shall communicate directl
y
or b
y
means of ducts
with the outdoors, crawl spaces or attic spaces.
Two
permanent openings,
2.
One permanent openings, commencing within 12 in (30.5 mm)of the
top of the enclosure shall be permitted where the equipment has
clearances of at least 1 in (2.54 cm) from the sides and back and
6 in (15.24 cm) from the front of the appliance. The opening shall
communicate directl
y
with the outdoors and shall have a minimum
free area of:
3.
The duct shall be least the same cross-sectional area as the free
area of the air suppl
y
inlet opening to which it connects.
1 square in per 3000 Btu per hour (6.45 cm
0.879 kW) of the
total input rating of all equipment located in the enclosure.
3
per
a.
Not less than the sum of all vent connectors in the confined space.
b.
4.
The blocking effects of louvers, grilles and screens must be given
consideration in calculating free area. If the free area of a specific
louver aor grille is not known.