background image

13

English

13

MOON PHASE

The moon phases 

(O)

 are displayed according to the 

calendar.

New moon 

First quarter 

Waxing half moon 

Second quarter 

Full moon 

Third quarter 

Waning half moon 

Last quarter

SNOOZE

Press the 

„SNOOZE“

 button 

7

 to interrupt the 

alarm for 5 minutes. Icons 

Z

Z

 and 

 flash during that 

period. Press any button apart from 

„SNOOZE“

 to 

complete the snooze function.

WEATHER FORECAST

The device forecasts weather conditions for the next 

12 - 24 hours based on changes in atmospheric pres-

sure. The catchment area covers approx. 30 – 50 

km. The weather forecasts have an accuracy of 70% 

– 75%. Since weather conditions cannot be forecast 

with 100% accuracy, we cannot be held responsible 

for any losses that are caused by incorrect weather 

forecasts.

Sunny 

Partially cloudy

Cloudy 

Rain (Snow) 

Cloudburst/Snowstorm

Important:

 The device must be in operation for at 

least 12 hours to record a pressure trend. The wea-

ther icons 

(P)

 are displayed on the basis of that trend.

Note:

 Places with various geographical situations,  

e.g. inland areas, windy valleys or coastal regions, 

have different weather forecasts. Your particular  

weather forecast 

(P)

 may be different in such areas.

INDICATORS FOR TEMPERATURE AND  

HUMIDITY TRENDS

If the values for temperature and humidity have 

changed, 4 small arrows indicate the tendency 

(K)

Rising, constant or falling.

MAINTENANCE AND CARE

Only clean the device with a soft cloth. If there is 

heavy soiling, the cloth can be moistened slightly. 

Never use detergents that contain solvent. 
Make sure no moisture gets inside the device. As 

regards the outdoor sensor, check to make sure the 

battery compartment cover is fitted properly, espe-

cially when you have changed the batteries.
If dust has accumulated in the opening of the sensor 

cover, it can be removed with a vacuum cleaner.

DISPOSING OF OLD EQUIPMENT

At the end of its life, do not dispose of this product 

in the normal household waste. Take it to a recycling 

collectionpoint for electrical and electronic equip-

ment. 
This is indicated by the symbol on the product, the 

operating instructions or the packaging.

DECLARATION OF CONFORMITY

We, Tegro AG (Ringstrasse 3, 8603 Schwerzenbach, 

Switzerland), declare with sole responsibility that this 

product conforms to the basic and other relevant 

requirements of Radio Equipment Directive 2014/53/

EU. To request the Declaration of Conformity please 

contact: info@tegro.ch

313532__Funk-Wetterstation_Manual_180410.indd   13

24.04.18   09:25

Summary of Contents for E0316

Page 1: ...wner s Manual Manuel de l utilisateur Manuale d istruzioni Funkwetterstation Wireless weather station Station m t orologique sans fil Stazione meteo wireless 313532__Funk Wetterstation_Manual_180410 i...

Page 2: ...2 Basic settings 12 Specifications 14 CONTENU Manuel de l utilisateur fran ais 15 Consignes de s curit 15 Description des fonctions 16 Configuration de la station et capteurs ext rieurs 18 R glages de...

Page 3: ...d rfen nur von einem Fachmann ausgef hrt werden Es d rfen keine Ver nderungen am Produkt vor genommen werden Bei einem Eingriff erlischt die Garantie Dieses Ger t und dessen Batterien sind kein Spiel...

Page 4: ...igen lassen Im Standartmodus 3 Sekunden gedr ckt halten um eine Alarmzeit einzustellen 5 CH Umschaltung Aussensensoren Im Standartmodus 3 Sekunden gedr ckt halten um Sensorsuche zu aktivieren 6 C F An...

Page 5: ...igkeit K Tendenz Trendanzeige L Minimum Maximum Wert Innentemperatur M Innentemperatur N Batteriestandanzeige Wetterstation O Mondphase P Symbole Wettervorhersage Q Luftdruckanzeige R Batteriestandanz...

Page 6: ...ehr als 3 Sekun den bis ein Piepton erklingt und das Symbol T zu blinken beginnt 2 Dr cken Sie die Taste TEST am Aussensensor um die Signal bertragung zu forcieren 3 Bei erfolgreicher Registrierung er...

Page 7: ...he Wettervorhersagen Ihre Wettervorhersage P kann in solchen Gebieten abweichen ANZEIGEN F R TEMPERATUR UND LUFTFEUCHTIGKEITSTRENDS Wenn sich der Wert f r die Temperatur und Luft feuchtigkeit ge ndert...

Page 8: ...62 32 49 inHg Genauigkeit Luftdruckbereich 3 hPa Aufl sung Luftdruck 1 hPa Zeitzonen 12 bis 12 Betriebstemperatur 0 C bis 50 C Abmessungen HxLxT 130 x 165 x 30 mm TECHNISCHE DATEN AUSSENSENSOR Spannun...

Page 9: ...by a qualified expert The product must not be subjected to modifica tions Any tampering will void the warranty This device and its batteries do not constitute a toy and should be stored out of childr...

Page 10: ...or 3 seconds to set an alarm time 5 CH Switch over outdoor sensors In standard mode hold down for 3 seconds to activate sensor search 6 C F Display switchover for C or F In standard mode hold down for...

Page 11: ...inimum maximum value of indoor temperature M Indoor temperature N Battery level indicator for weather station O Moon phase P Weather forecast icons Q Atmospheric pressure indicator R Battery level ind...

Page 12: ...is indicated on the display If the battery level is low or the link fails the sensor has to be detected manually 1 Press the CH button for more than 3 seconds until you hear a beep and the icon T star...

Page 13: ...ecast P may be different in such areas INDICATORS FOR TEMPERATURE AND HUMIDITY TRENDS If the values for temperature and humidity have changed 4 small arrows indicate the tendency K Rising constant or...

Page 14: ...32 49 inHg Accuracy of atmospheric pressure range 3 hPa Resolution of atmospheric pressure 1 hPa Time zones 12 to 12 Operating temperature 0 C to 50 C Dimensions HxLxD 130 x 165 x 30 mm OUTDOOR SENSOR...

Page 15: ...tre r alis s par un professionnel qualifi Aucune modification ne doit tre effectu e sur le produit Toute garantie est annul e en cas d intervention sur l appareil Cet appareil et ses piles ne sont pa...

Page 16: ...des pour r gler une heure d alarme 5 CH Commutation des capteurs ext rieurs En mode standard actionner pendant 3 secon des pour activer la recherche des capteurs 6 C F Commutation de l affichage entre...

Page 17: ...Valeur minimum maximum pour la temp rature int rieure M Temp rature int rieure N Indicateur de charge des piles de la station m t orologique O Phase de la lune P Symbole de pr vision m t o Q Affichag...

Page 18: ...tr manuellement 1 Actionnez la touche CH pendant plus de 3 secondes jusqu entendre un bip et voir le symbole T se mettre clignoter 2 Actionnez la touche TEST sur le capteur ext rieur pour forcer la tr...

Page 19: ...Vos pr visions m t o P peuvent varier dans ces r gions AFFICHAGES DE TENDANCE POUR LA TEMP RATURE ET L HYGROM TRIE Lorsque les valeurs de temp rature et d hygrom trie ont chang 4 petites fl ches indi...

Page 20: ...ique 800 1100 hPa 23 62 32 49 inHg Pr cision de la pression atmosph rique 3 hPa R solution de la pression atmosph rique 1 hPa Fuseaux horaires 12 12 Temp rature d utilisation 0 C 50 C Dimensions HxLxP...

Page 21: ...lo da uno specialista Non possono essere effettuate modifiche sul pro dotto In caso di un intervento decade la garanzia Questo apparecchio e le sue batterie non sono un giocattolo e devono essere tenu...

Page 22: ...tandard tenere premuto per 3 secondi per impostare un orario dell allarme 5 CH Commutazione sensori esterni Nella modalit standard tenere premuto per 3 secondi per attivare la ricerca del sensore 6 C...

Page 23: ...tendenza trend L Valore minimo massimo temperatura interna M Temperatura interna N Indicazione livello batteria stazione meteo O Fase lunare P Simboli previsioni meteo Q Visualizzazione pressione aria...

Page 24: ...il sensore deve essere registrato manualmente 1 Premere il tasto CH 5 per pi di 3 secondi finch non viene emesso un segnale acustico ed il simbolo T non inizia a lampeggiare 2 Premere il tasto TEST s...

Page 25: ...previsioni meteo P possono variare in queste zone VISUALIZZAZIONE PER TREND DI TEMPERATURA E UMIDIT DELL ARIA Se variato il valore per la temperatura e l umidit dell aria 4 piccole frecce indicano la...

Page 26: ...ll aria 800 1100 hPa 23 62 32 49 inHg Precisione range pressione dell aria 3 hPa Risoluzione pressione dell aria 1 hPa Fusi orari Da 12 a 12 Temperatura di esercizio da 0 C a 50 C Dimensioni AxLxP 130...

Page 27: ...27 Italiano 313532__Funk Wetterstation_Manual_180410 indd 27 24 04 18 09 25...

Page 28: ...zione giorno mese E0316 313532 00 Tegro AG CH 8603 Schwerzenbach www tegro ch Aussentemperatur Outdoor temperature Temp rature ext rieur Temperatura esterno Aussenluftfeuchtigkeit Outdoor humidity Hum...

Reviews: