APPENDIX D: LVDT OPTION
HF25 DC RESISTANCE WELDING SYSTEM
990-333
D-13
STOP ENERGY AT: (Weld to a Specific Displacement)
You can program the LVDT to stop the current flow in the middle of the weld once it has reached a
specific displacement.
1
From the main LVDT screen, press the
SCHEDULE
button to edit the screen.
2
Scroll to
WELD TO.
3
Use the numerical keypad on the front of the Control to enter a numerical value of the
displacement when you want the weld energy to stop.
Example:
On the LVDT screen, the
results show that the
STOP ENERGY AT
displacement was programmed for
003”
.
The
STOP ENERGY AT
number will
always be less than the actual
displacement. The actual displacement
was
+010”
as shown in the
LAST
WELD STOP-DISPLC REACHED @8MS
0000283
LO
LIM
HI
LIM
LAST
INITIAL
+000
000
+056
CONT
FINAL
+000 +
+000
+046
DISPLC
+000
000
+010
18%
STOP ENERGY AT
003
008
IN/1000
NEW ELECTRODE:
IS SET
SCHEDULE or DISTANCE Edit, RUN Run
column (Last Weld). The time at which
the weld reached the displacement limit
is shown in the
LAST
column.
On the
RUN
screen, the same
information is displayed on the right.
The current (shaded graph) was turned
OFF before the programmed time
because the
WELD TO
thickness was
reached.
NOTE:
See relay screens for options to signal operators or automation of errors.