APPENDIX E. COMMUNICATIONS
HF25D LINEAR DC RESISTANCE WELDING CONTROL
990-333
E-5
Computer Originated Commands
These are the commands sent by the host computer, via RS-485 or RS-232 to a Control.
Command
STATUS
<crlf><lf>
Control State
Any
Description
Requests the Control to report the status of the weld data buffer. Control returns
STATUS
with either “
OK
” or “
OVERRUN.
”
Command
TYPE
<crlf><lf>
Control State
Any
Description
Requests the Control to return the type of welder, release number, and revision letters.
NOTE:
HF25 software lower than version 1.29 will not display release number or revision
letter.
Command
COUNT
<crlf><lf>
Control State
Any
Description
Requests the Control to report the number of weld data accumulated since the last data
collection. Control returns the COUNT even if there is no weld data available.
Command
ERASE
<crlf><lf>
Control State
Any
Description
Requests the Control to erase all the weld reports.
Command
SYNC
<crlf><lf>
Control State
Any
Description
Provides synchronization of the commands. The Control returns SYNC command back to the
host computer.
Command
CURRENT
<crlf><lf>
Control State
Any
Description
Requests the Control to report the sampled Current data of the last weld. Control shall return
with CURRENT report. See CURRENT command under Control Originating Commands
section.
Command
VOLTAGE
<crlf><lf>
Control State
Any
Description
Requests the Control to report the sampled Current data of the last weld. Control shall return
with VOLTAGE report. See VOLTAGE command under Control Originating Commands
section.