APPENDIX E. COMMUNICATIONS
HF25D LINEAR DC RESISTANCE WELDING CONTROL
990-333
E-7
Command
COPY {
from_schedule_number
} {
to_schedule_number
}
<crlf><lf>
Control State
Any
Description
Allows one schedule to be copied to another schedule number. From_schedule_number and
to_schedule_number may be any number from 0 to 99. Copying a schedule to itself has no
effect other than to invoke a schedule printout when "PRINT SCHEDULES/PROGRAMS" is
enabled.
Command
SCHEDULE
<crlf><lf>
Control State
Any state
except
while welding.
Description
Requests the Control to return the currently selected schedule number.
Command
SCHEDULE {READ | SET}
<crlf>
[
parameter_name value
<crlf>]
<lf>
Control State
RUN state.
Description
Provides control over the Control schedule parameters. When used with the "READ"
keyword, all parameters pertaining to the currently loaded schedule are returned (see
SCHEDULE under Control ORIGINATED COMMANDS). When the "SET" keyword is
used, the host may set (change) the value of one or more of the parameters pertaining to the
currently loaded schedule. The following is a list of valid literal substitutions for the
parameter_name and value variables:
ENG1
FEEDBACK1
ENG2
FEEDBACK 2
SQUEEZE
UP1
WELD1
DOWN1
COOL
UP2
WELD2
DOWN2
HOLD
{
weld_energy
}
energy amount for pulse 1
{ KA | V | KW}
feedback type for pulse 1
{
weld_energy
}
energy amount for pulse 2
{ KA | V | KW}
feedback type for pulse 2
{
squeeze_time
}
squeeze time
{
weld_time
}
up slope time of pulse 1
{
weld_time
}
weld time of pulse 1
{
weld_time
}
down slope time of pulse 1
{
weld_time
}
cool time
{
weld_time
}
up slope time of pulse 2
{
weld_time
}
weld time of pulse 2
{
weld_time
}
down slope time of pulse 2
{
hold_time
}
hold time