background image

13

www.csunitec.com

Original instructions VARILEX

®

 1802 HT

EN

14. Repairs

Repairs to power tools must only be 

carried out by qualified electricians!

If the connection lead is damaged, it must be 

replaced by a special connection lead.
Contact CS UNITEC if you have Eisenblätter 

power tools requiring repairs:
CS. UNITEC Inc. 

22 Harbor Ave  

Norwalk, CT 06850 

USA

1-

800-700-5919

info@csunitec.com

www.csunitec.com

15. Environmental protection

The generated sanding dust may contain 

harmful  substances: dispose of 

appropriately.
Observe national regulations on 

environmentally 

 compatible disposal and on the recycling of 

disused tools, packaging and accessories.

Only  for  EU  countries:  never  dispose 

of  power  tools  in  your  household 

waste!  In  accordance  with  European 

Directive 2002/96/EC relating 

to electrical and electronic waste and 

implementation of national law, used electrical 

tools must be collected separately and disposed 

of in an environmentally friendly manner at 

recycling centres.

1-800-700-5919 (US/CA)

www.csunitec.com 

info@csunitec.com

+1-203-853-9522 (Intl.)

Summary of Contents for VARILEX 1802 HT

Page 1: ...VARILEX 1802 HT 110V Made in Germany EN Original instructions 4 www csunitec com 1 800 700 5919 US CA www csunitec com info csunitec com 1 203 853 9522 Intl...

Page 2: ...2 www csunitec com Original instructions VARILEX 1802 HT EN 1 2 A2 A1 1 2 B1 B2 4 3 4 3 1 800 700 5919 US CA www csunitec com info csunitec com 1 203 853 9522 Intl...

Page 3: ...3 www csunitec com Original instructions VARILEX 1802 HT EN D1 D2 3 4 2 5 E2 E1 1 1 2 C1 C2 C3 1 1 2 1 1 800 700 5919 US CA www csunitec com info csunitec com 1 203 853 9522 Intl...

Page 4: ...stone and similar materials without the use of water Recommendation For demanding polishing work in continuous use we recommend our angle polishers VARILEX POLISHER HT and VARILEX POLISHER AKKU It is...

Page 5: ...balance vibrate excessively and may cause loss of control Do not use a damaged accessory Before each use inspect the accessory such as abrasive wheels for chips and cracks backing pad for cracks tear...

Page 6: ...endency to snag the rotating accessory and cause loss of control or kickback Do not attach a saw chain woodcarving blade or toothed saw blade Such blades create frequent kickback and loss of control 5...

Page 7: ...erference of the wire wheel or brush with the guard Wire wheel or brush may expand in diameter due to work load and centrifugal forces 5 7 Additional safety instructions WARNING Always wear protective...

Page 8: ...safety regulations disposal Collect the generated particles at the source avoid deposits in the surrounding area Use suitable accessories for special work see chapter 8 thus less particles enter the...

Page 9: ...change in accordance with technical progress Measured values determined in conformity with EN 60745 Direct current cordless machines Alternating current mains powered machines Machine in protection cl...

Page 10: ...C2 and C3 Push and hold the lever C1 1 Place the safety cover C2 in the position indicated Release the lever and turn the safety cover until the lever engages Push the lever and turn the safety cover...

Page 11: ...w the clamping nut onto the spindle D1 2 as follows Forthin grinding discs Theedge o f the clamping nut D1 4 faces upwards sothat the thin grinding wheel can be attached securely Forthick grinding dis...

Page 12: ...ease in the front position to lock the trigger switch continuous operation Switching off Push the trigger switch A2 4 upwards and release 12 Troubleshooting The electronic signal indicator A2 1 lights...

Page 13: ...tion The generated sanding dust may contain harmful substances dispose of appropriately Observe national regulations on environmentally compatible disposal and on the recycling of disused tools packag...

Page 14: ...14 www csunitec com 1 800 700 5919 US CA www csunitec com info csunitec com 1 203 853 9522 Intl...

Page 15: ...15 www csunitec com 1 800 700 5919 US CA www csunitec com info csunitec com 1 203 853 9522 Intl...

Page 16: ...US CA 1 203 853 9522 Intl Fax 2038539921 info csunitec com www csunitec com CS UNITEC Inc 22 Harbor Avenue Norwalk CT 06850 USA 4330 Center Street Deer Park TX 77536 USA 1 800 700 5919 US CA www csun...

Reviews: