power-up. After 10 keys (other than Shift keys) are pressed, setup will not be
activated except by a system restart or by simply unplugging and re-plugging the
keyboard connector on your computer.
During setup, only Numeric keys (0 to 9) on the top row of keyboard are
accepted; Numeric keypad on the right of keyboard is not supported.
3.2. Setup the Keyboard from Bar Code Menu
The Menu setup lets the user configure the Reader by scanning labels into a setup
menu from Appendix B. The setup menu contains 8 groups as following:
Group 1: Beep and Delay
Group 2: Keyboard Interface
Group 3: Scanner Port
Group 4: Magnetic Reader
Group 5: Code 39, I 2 of 5, S 2 of 5, code 32, and EAN128
Group 6: Code 128, MSI, Code 93, Codabar, and Label Code
Group 7: UPC/EAN, and Delta Distance Code
Group 8: Data Editing
3.2.1. General Settings
For most parameters, follow the steps below:
1) Locate a group that contains the parameter to be changed.
2) Scan the “Enter Group” label to enter setup. The Keyboard will beep three times
to indicate that setup has begun.
3) Scan the label (on the right side) representing the parameter to be changed.
4) Scan the labels (number) representing the desired parameter value.
5) Repeat step 3 and 4, if necessary, to change the parameters in the same group.
6) Scan the “Exit” label to end the group setup. The Keyboard will beep twice and
return to normal.
3.2.2. Bar Code Length setting (example)
The following example illustrates how to set Code 39 with a minimum length of 5 and
a maximum length of 20:
* Scan Enter Group 5
* Scan F1 to select Code 39
* Scan MIN LENGTH to enter minimum length setting
* Scan 0 and 5 to select length 5
* Scan MIN LENGTH to end minimum length setting
* Scan MIN LENGTH to enter maximum length setting
* Scan 2 and 0 to select length 20