16
MS100
Man
ual
Bar Code Symbologies, continued
Code 128
Enabled
toggles the ability for the keyboard/scanner to read
Code 128 on or off. Default is “Yes”.
•
Code ID
is a user-definable identification letter for Code 128,
which is referred to in the “Use Code ID” function (see page
11
).
Default is letter “K”.
•
Minimum Length
defines the minimum length the user will
accept for a valid bar code. Default is “1”.
•
Maximum Length
defines the maximum length the user will
accept for a valid bar code. Default is “64”.
•
EAN 128
Field Separator
is a user-definable character to insert between
fields. Default is “None”.
•
Enable Code ID
determines whether or not to assign a Code ID.
Default is “No”.
•
Code ID
is a user-definable identification letter for EAN 128,
which is referred to in the “Use Code ID” function (see page
11
).
Default is “None”.
•
Enabled
toggles the ability for the keyboard/scanner to read EAN
128 on or off. Default is “No”.
•
Code 32
Enabled
toggles the ability for the keyboard/scanner to read
Code 32 on or off. Default is “No”.
•
Code ID
is a user-definable identification letter for Code 32,
which is referred to in the “Use Code ID” function (see page
11
).
Default is letter “T”.
•
Send Leading Character
toggles sending or not sending a
leading (“start bar code”) character. Default is “Send”.
•