6
© 2016 unitech Electronics Co., Ltd. All rights reserved.
unitech is a registered trademark of unitech Electronics Co.,Ltd
1.4 Getting Started
Please scan below barcode to set default for BT parameter.
For configuration, please refer to
BT Parameter Set Default
1.4.1 Scanner Mode
There are three different scanner modes. Please follow the instructions below.
A. Setup SPP Master Mode*
(Default option)
SPP Master Mode*
Please follow the below steps to setup the communication between
the scanner and cradle
.
1) The scanner must scan “SPP Master Mode” barcode to set the scanner in master mode.
2) Scan the BT MAC address code located on the bottom of the cradle.
3) When the BT MAC address code was successfully scanned, scanner will sound 3 short
beeps with green LED flash once.
4) Wait approximately five seconds for completing the connection process with up-tone.
5) If successful, blue LED of scanner will slow flash and the cradle will be continued on.
B. Setup SPP Slave Mode
SPP Slave Mode
Please follow the below steps to setup the communication between
the scanner and BT
application device
.
1) The scanner must scan “SPP Slave Mode” barcode, to set the scanner in slave mode.
2) When control the BT device to search the scanner, enter pin code (default 00:00:00) to
setup comport.
3) When scanner is successful connected, the scanner blue LED will also blink with up-tone.
Blue LED will slowly flash to finish the setup.