3.9 Codabar coupling, Adjacent
Required
Codabar Coupling
On
Off
Set insert Data *
* The data can be any alphanumerics of FULL
ASCII Table
Insert Data On
Insert Data Off
ABC-Codabar and CX-Codabar have
certain rules regarding the Stop Character
of first bar code and the stop character of
second bar code while in conjunction, while
Codabar- Coupling is enabled, the data
from any two Codabar bar codes can be
coupled into one set of data without any
limitations between the Stop character of
first bar code and the Start character of
second bar code. The Start and Stop
characters associated with each bar code
will be sent.