Enter Setup
**
Exit Setup
8
Stop Bit
** 1 Stop Bit
2 Stop Bits
Hardware Flow Control
If this feature is enabled, the engine determines whether to transmit data based on CTS signal level. When CTS signal is at
a low level which means the serial port’s cache memory of receiving device (such as PC) is full, the engine sends data
through RS-232 port until CTS signal is set to high level by receiving device. When the engine is not ready for receiving, it
will set RTS signal to low level. When sending device (such as PC) detects it, it will not send data to the engine any more to
prevent data loss.
If this feature is disabled, reception/transmission of serial data will not be influenced by RTS/CTS signal.
Enable Hardware Flow Control
** Disable Hardware Flow Control
Note:
Before enabling this feature, make sure that RTS/CTS signal line is contained in RS-232 cable. Without the signal
line, serial communication errors will occur.