4.6.7 Aimer Delay
The aimer delay allows a delay time for the operator to aim the scan engine
before the picture is taken. Use these codes to set the time between when
the trigger is pulled and when the picture is taken. During the delay time, the
aiming light will appear, but the LEDs won’t turn on until the delay time is over.
Default = Off.
200 milliseconds
400 milliseconds
Off (no delay) *
4.6.7.1 Aimer Mode
This feature allows you to turn the aimer on and off. When the Interlaced
bar code is scanned, the aimer is interlaced with the illumination LEDs.
Default = Interlaced.
Interlaced*
Off