- 19 -
© 2019 unitech Electronics Co., Ltd. All rights reserved.
unitech is a registered trademark of unitech Electronics Co., Ltd.
MS852Plus User’s Manual
3.3.1.2 Codabar Check Characters
Codabar check characters are created using different “modulos.” You can
program the scanner to read only Codabar bar codes with Modulo 16 check
characters. Default = No Check Character.
No Check Character
indicates that the scanner reads and transmits bar code
data with or without a check character.
When Check Character is set to
Validate and Transmit
, the scanner will only
read Codabar bar codes printed with a check character, and will transmit this
character at the end of the scanned data.
When Check Character is set to
Validate, but Don’t Transmit
, the unit will
only read Codabar bar codes printed with a check character, but will not
transmit the check character with the scanned data.
No Check Character*
Validate Modulo 16, but Don’t Transmit
Validate Modulo 16 and Transmit