MS860G WiFi Manual
33
SCANNER CONFIGURATION MANAGER
Bar Code Symbologies, continued
Codabar
•
Enabled
toggles the ability for the scanner to read Codabar
on or off.
Default is “Yes”.
•
Code ID
is a user-definable identification letter for Codabar,
which is referred to in the “Use Code ID” function on page 25.
Default is letter “N”.
•
Send Start/Stop
toggles sending or not sending start/stop
sentinels.
Default is “No Send”.
•
Check Digit
defines whether or not a check digit (to insure
data accuracy) is calculated, and if so, whether it should be
sent or not.
Default is “Not Calculate”.
•
CLSI Format
deletes the start and stop sentinels, and outputs
the data with spaces inserted after the 1st, 5th, and 10th
characters.
Default is “No”.
•
Minimum Length
defines the minimum length the user will
accept for a valid bar code.
Default is “3”.
•
Maximum Length
defines the maximum length the user will
accept for a valid bar code.
Default is “48”.
UPC-A
•
Enabled
toggles the ability for the scanner to read UPC-A on or
off.
Default is “Yes”.
•
Code ID
is a user-definable identification letter for UPC-A,
which is referred to in the “Use Code ID” function on page 25.
Default is letter “A”.
•
Send Leading Digit
toggles sending or not sending a leading
(‘start bar code’) digit.
Default is “Send”.
•
Send Check Digit
toggles sending or not sending a check
digit.
Default is “Send”.