FCC WARNING STATEMENT

This equipment has been tested and found to comply with the limits for a Class B digital 

device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not 

installed and used in accordance with the instructions, may cause harmful interference 

to radio communications. However, there is no guarantee that interference will not 

occur in a particular installation. If this equipment does cause harmful interference to 

radio or television reception, which can be determined by turning the equipment off 

and on, the user is encouraged to try to correct the interference by one of the following 

measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the 

receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

CANADIAN DOC STATEMENT

This digital apparatus does not exceed the Class B limits for radio noise for digital 

apparatus set out in the Radio Interference Regulations of the Canadian Department of 

Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les 

limites applicables aux appareils numériques de las classe B prescrites dans le 

Réglement sur le brouillage radioélectrique édicté par les ministère des Communica-

tions du Canada.

CE MARKING AND EUROPEAN UNION COMPLIANCE 

Testing for compliance to CE requirements was performed by an independent 

laboratory. The unit under test was found compliant with all the applicable Directives, 

2004/108/EC and 2006/95/EC.

WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT

The WEEE directive places an obligation on all EU-based manufacturers and

importers to take-back electronic products at the end of their useful life. 

ROHS STATEMENT OF COMPLIANCE

This product is compliant to Directive 2002/95/EC.

NON-MODIFICATION STATEMENT

Changes or modifications not expressly approved by the party responsible for 

compliance could void the user's authority to operate the equipment 

RoHS

1

 -

1. Take any metals into contact with the terminals in connectors.
2. Use the scanner where any inflammable gases.

If following condition occur, immediately power off the host computer, 

disconnect the interface cable, and contact your nearest dealer.
1. Smoke, abnormal odors or noises come from the scanner.
2. Drop the scanner so as to affect the operation or damage its housing.

Do Not

Do not do behavior below.
1. Put the scanner in places excessively high temperatures such as expose 

under direct sunlight.

2. Use the scanner in extremely humid area or drastic temperature 

changes.

3. Place the scanner in oily smoke or steam environment such as cooking 

range.

4. Be covered or wrapped up the scanner in bad-ventilated area such as 

under cloth or blanket.

5. Insert or drop foreign materials or water into scanning window or vents.
6. Using the scanner while hand is wet or damp.
7. Use the scanner with anti-slip gloves containing plasticizer and 

chemicals or organic solvents such as benzene, thinner, insecticide etc 

to clean the housing. Otherwise, it could not result fire and electrical 

shock but housing may be broken and injured.

8. Scratch or modify the scanner and bend, twist, pull or heat its interface 

cable.

9. Put heavy objects on interface cable.
Do not stare the light source from the scanning window or do not point the 

scanning window at other people’s eyes or eyesight may be damaged 

by direct exposure under the light.

Do not put the scanner on an unstable or inclined plane.
The scanner may drop, creating injuries.

Once the interface cable is damaged such as exposed or broken copper 

wires, stop using immediately and contact your dealer. Otherwise, it could 

result fire or electrical shock.

WARNING AND CAUTION

2

 -

Summary of Contents for MS912+

Page 1: ...because we care MS912 Wireless Barcode Scanner Quick Guide Version 1 5 For more detailed scanner setting please go to www ute com to download the user manual and scanner configuration manager utility...

Page 2: ...ased manufacturers and importers to take back electronic products at the end of their useful life ROHS STATEMENT OF COMPLIANCE This product is compliant to Directive 2002 95 EC NON MODIFICATION STATEM...

Page 3: ...4mil 0 1mm PCS 30 Housing Plastic PC ABS Profile SPP HID Battery Life 6000 scans 1 scan 5 sec Charge Time 2 hours fully charged Coverage 10M 33ft line of sight Operating Temp 0 to 50 C 32 F to 122 F...

Page 4: ...power Charging 6 Single long beep Power up Single beep Good read Single short beep The scanner reads a Code39 of ASCII in configuration procedure Two beeps i Wireless connection ii The scanner succes...

Page 5: ...each barcode data to the host after decode See page 9 for details 3 Batch Mode Emulates a USB mass storage device that saves each barcode data during off line data collection See page 25 4 USB HID Emu...

Page 6: ...y the connection E042 BT mode SPP E042 E032 E032 E033 E033 Disconnect E031 E031 TX TX E043 BT mode HID E043 1 Press and hold the trigger for 1 second to activate the scanner 2 Scan DISCONNECT 3 Scan B...

Page 7: ...11 12 NUMERIC BARCODES 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 0 0...

Page 8: ...r off Touch Keyboard iOS Touch Keyboard Android After enabling iOS Hotkey disabled by default you may simply double click the trigger to toggle the iPhone iPad Touch Keyboard Please follow below steps...

Page 9: ...GENERAL SETTINGS 15 16 TERMINATOR LF CR LF NONE SPACE TAB D012 CR D011 D013 D010 D015 D014 BEEPER P023 A007 F012 ABORT CHECK VERSION BEEP OFF F018 A001 DEFAULT BEEP ON...

Page 10: ...D LAYOUT C010 ENGLISH USA C018 ENGLISH UK C011 GERMAN C012 FRENCH C013 SPANISH 17 C014 ITALIAN C009 JAPAN 106 key 18 CANADIAN TRADITIONAL C034 NORWEGIAN C029 SWEDISH C026 PORTUGUESE C031 CANADIAN FREN...

Page 11: ...BRAZILIAN PORTUGUESE SLOVAK SWISS FRENCH DUTCH DANISH BELGIAN AZERTY C016 SWISS GERMAN KEYBOARD LAYOUT C017 CZECH QWERTY C022 CZECH QWERTZ HUNGARIAN QWERTZ C021 C015 ALT CODE 19 20 C024 C023 C033 C03...

Page 12: ...IES ENABLE ALL CODE A002 K010 CODE 32 L010 N001 M010 L001 UK PLESSEY MSI INDUSTRIAL 2 OF 5 MATRIX 2 OF 5 21 CODE 93 L014 G010 N017 N032 N010 N026 IATA TELEPEN GS1 DATABAR GS1 DATABAR LIMITED GS1 DATAB...

Page 13: ...connection is made beforehand Once enabled a checksum will be added to the end of each data to conduct Xor calculation For Bluetooth SPP USB VCP the BCC is 1 byte For Bluetooth HID the BCC are 2 byte...

Page 14: ...SCII table 3 Scan Field Separator R010 R010 FIELD SEPARATOR R011 R011 DATA FORMAT 2 4 Date Barcode Data Code Item Code Item 3 Time After scanning the above barcode the scanner will be able to collect...

Page 15: ...7 08 DD MM YYYY MM DD YYYY DD MM YY MM DD YY YYYY MM DD YY MM DD DD MM MM DD Code Format Code Format 09 10 11 12 13 14 15 16 DD MM YYYY MM DD YYYY DD MM YY MM DD YY YYYY MM DD YY MM DD DD MM MM DD The...

Page 16: ...t Time 2 Scan 0 8 1 0 3 0 on page 11 12 3 Scan Set Time R006 R006 SET DATE R007 R007 SET TIME DATE TIME SETUP For MS912M only To avoid Time and Date being reset to factory default due to running low o...

Page 17: ...31 32...

Page 18: ...33 34...

Reviews: