25
Unitech electronics co., ltd.
5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.)
Tel: + 886 2 89121122
Fax: +886 2 89121810
website: www.ute.com
. R013$
USB-VCP
To output stored data via Wireless, please do the following:
1. Scan [
WIRELESS
]
2. Scan [
OUTPUT DATA
]
To output stored data via USB-VCP, please do the following:
1. Install VCP driver (available on CD)
2. Connect the scanner & host with USB cable
3. Scan [
USB-VCP
]
4. Save data as * .csv by “Covert to CSV.exe” (available on CD)
DATA FORMAT
. R011$
DATA FORMAT
The default Data Format is <Item No.>, <Date>, <Time>, <Barcode Data> below are items and
their setup codes:
Code
Item
Code
Item
1
Item No.
3
Time
2
Date
4
Barcode Data
Example:
To change Data Format to <Item No.>, <Barcode Data>, <Date>, <Time>
1. Scan [
Data Format
]
2. Scan [1], [4], [2], [3] on page 39.
3. Scan [
Data Format
]
. R011$
FIELD SEPARATOR
Default is comma ( , ) . You may replace it with any alphanumeric
characters from the full ASCII table in User’s Manual (on CD).
Example: To change Field Separator to Semicolon ( ; )
1. Scan [
Field Separator
]
2. Scan [
;
] from the full ASCII table.
3. Scan [
Field Separator
]