3.3.1.2 Codabar Check Characters
Codabar check characters are created using different “modulos.” You can
program the scanner to read only Codabar bar codes with Modulo 16 check
characters. Default = No Check Character.
No Check Character
indicates that the scanner reads and transmits bar code
data with or without a check character.
When Check Character is set to
Validate and Transmit
, the scanner will only
read Codabar bar codes printed with a check character, and will transmit this
character at the end of the scanned data.
When Check Character is set to
Validate, but Don’t Transmit
, the unit will
only read Codabar bar codes printed with a check character, but will not
transmit the check character with the scanned data.
No Check Character*
Validate Modulo 16, but Don’t Transmit
Validate Modulo 16 and Transmit