3.1.1 Operation Mode
Configure the Operation Mode for either Trigger
Mode or Auto Mode.
Configuration Method:
Select one of the two options then click
to send the new parameter to the RP901.
Default Setting: Trigger Mode
Detailed explanations of Trigger Mode and Auto Mode are as following:
(1) Trigger Mode Operation Method:
<A> Press the Trigger button to start a tag scan operation. Upon successful
tag scan (Good Read) the Scan operation will stop.
<B> In Single-Tag Read mode, if the Trigger button is pressed but no
successful tag scan occurred within the scan operation, the scan
operation will terminate. In any case, releasing the Trigger button will
terminate the scan operation.
<C> In Multi-Tag Read mode, If the Trigger button is pressed but the number
of tags read is smaller than Tag-List Counter within the scan operation,
the scan operation will be paused. Pressing the Trigger button again will
continue the scan operation. In any case, releasing the Trigger button
will pause the scan operation.
<D> In Sleep Mode, pressing the Trigger button will automatically reactivate
Trigger Mode.
(2) Auto Mode Operation Method:
<A> The Auto Mode follows the same rules of operation as the Trigger Mode,
except that scan operation start automatically, without pressing the Trigger
button.
<B> Scan Operation is repeated and do not terminate unless the RP901
enters Sleep Mode.
<C> In Sleep Mode, Pressing the Trigger button will automatically reactivate
Auto Mode.
CAUTION ! Auto Mode is more power-consuming.
27
© 2016 unitech Electronics Co., Ltd. All rights reserved.
unitech is a registered trademark of unitech Electronics Co.,Ltd