WirelessHART Toxic & Combustible Gas Detector
IM_TCD60-01
www.ueonline.com/vanguard
16
2.6.5 Universal Mount
1.
Remove hardware from packaging (see Figure 26).
2.
Thread clamp [8] through the holes on the mounting bracket plate [3] (see Figure 26, 27).
3.
Wrap the clamp [8] around the mounting structure and insert the end under the worm drive screw
[9] (see Figure 28).
4.
Pull the end through until it is hand tight around the mounting structure and flip down the worm
drive screw [9].
5.
Use a socket or screwdriver to tighten the clamp. This clamp should lock into place and be tool-tight.
6.
Mount device by hooking onto top pin of mounting bracket plate (see Figure 28).
7.
Push attached pin [5] through bottom holes to secure device to the bracket (see Figure 29).
2.6.6 Device removal from mounting bracket plate
Removing the device from the mounting bracket plate for maintenance or calibration is simple.
1. Pull attached pin [5] through bottom holes using the pull ring.
Figure 26
Figure 27
Figure 28
Figure 29
[9]
[5]
[3]
[8]