-3-
Combustible:
Wood
Flue Pipe Diameter:
6” (153mm)
Flue Pipe Type: (Standard,
Single Wall, or Double Wall):
Black or Blued Steel 2100°F (650°C) Class “A”
Minimum Chimney Height:
12’
Maximum Log Length:
20”
Electrical
120V, 60Hz, 2.6A
Dimensions
Combustion Chamber:
Width x Depth:
12.8” X 20.3”
Volume:
Cubic Feet:
3.0 cubic feet
Door Opening: Width x Height: 11.6” X 11.5”
Weight (lbs):
350lbs
Specifications
CONGRATULATIONS!
You’ve purchased a heater from North America’s oldest manufacturer of wood burning products.
By heating with wood you’re helping to CONSERVE ENERGY!
Wood is our only Renewable Energy Resource. Please do your part to preserve our wood supply. Plant at least
one tree each year. Future generations will thank you.
This manual describes the installation and operation of the Hotblast, 1331E wood heater.
This heater meets the 2016 U.S. Environmental Protection Agency’s emission limits for wood
heaters sold after May 15, 2016. Under specific EPA test conditions this heater has been
shown to deliver heat at a rate of 18,850 – 56,000 BTU/hr. This heater achieved a particulate
emissions rate of 0.509 lb/mmBtu when tested to method CSA B415.1-10 (*and an overall
efficiency of 60.01 %). The maximum overall heat output of this heater was tested to be
89,000 Btu/hr.
This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating
instructions in this manual.
The operation of this wood heater in a manner inconsistent with the owner’s manual will void you warranty and
is also against federal regulations.
This heater is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when
burning air dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods.
This wood heater needs periodic inspection and repair for proper operation. It is against federal regulations to
operate this wood heater in a manner inconsistent with operating instructions in this manual.
0215WH056E