Run 1.xlsm
Client: USSC
Job #: 22-753
Model: KP5522
Tracking #: 121
Run #: 1
Technician: SJB
Date:
Particulate Sampling Data
Elapsed
Time
(min)
Gas Meter
(ft
3
)
Sample
Rate (cfm)
Dilution
Tunnel dP
(in H
2
O)
Orifice
dH
(in H
2
O)
Meter
Temp (°F)
Meter
Vacuum
(in Hg)
Pro. Rate
(%)
Scale
Reading
Weight
Change
Dilution
Tunnel
Flue
Filter
Ambient
2/18/2022
BOX A TEST DATA - ASTM E2779 / ASTM E2515
Fuel Weight (lb)
Temperature Data (°F)
204
38.505
0.188
0.032
1.48
59.5
-1.57
98
5.8
0.0
81
216
71
67.5
205
38.694
0.189
0.032
1.48
59.6
-1.48
98
5.8
-0.1
81
215
71
67.5
206
38.883
0.189
0.030
1.48
59.5
-1.55
102
5.7
-0.1
81
214
71
67.5
207
39.072
0.189
0.031
1.48
59.4
-1.61
100
5.7
-0.1
81
216
71
67.2
208
39.262
0.190
0.030
1.48
59.3
-1.64
102
5.6
0.0
81
216
71
67.3
209
39.451
0.189
0.032
1.48
59.2
-1.44
98
5.6
0.0
81
216
71
67.3
210
39.640
0.189
0.032
1.49
59.1
-1.52
98
5.6
0.0
81
215
71
67.3
211
39.828
0.188
0.032
1.47
59
-1.42
98
5.5
0.0
80
214
71
67.3
212
40.017
0.189
0.032
1.48
59
-1.44
99
5.5
0.0
80
214
71
67.2
213
40.205
0.188
0.031
1.48
59
-1.57
100
5.5
0.0
80
215
71
67.2
214
40.394
0.189
0.031
1.48
58.9
-1.66
100
5.4
0.0
80
213
71
67.2
215
40.584
0.190
0.031
1.48
58.9
-1.51
101
5.4
0.0
80
210
71
67.1
216
40.773
0.189
0.030
1.49
59.1
-1.47
102
5.3
-0.1
80
212
71
67.2
217
40.962
0.189
0.032
1.49
59
-1.59
98
5.3
-0.1
80
213
71
67.1
218
41.150
0.188
0.031
1.48
59
-1.63
100
5.3
0.0
80
213
71
67.1
219
41.339
0.189
0.031
1.48
58.9
-1.66
100
5.2
0.0
80
212
71
67.1
220
41.527
0.188
0.030
1.47
59
-1.66
101
5.2
0.0
80
212
71
67.1
221
41.716
0.189
0.032
1.48
59.1
-1.66
98
5.2
0.0
80
212
71
67.1
222
41.906
0.190
0.032
1.48
59.2
-1.57
99
5.1
0.0
80
210
71
67
223
42.094
0.188
0.031
1.48
59.1
-1.53
99
5.1
0.0
80
207
71
67
224
42.283
0.189
0.031
1.46
59.1
-1.57
100
5.1
-0.1
80
208
71
66.9
225
42.471
0.188
0.031
1.47
58.9
-1.5
100
5.0
0.0
80
207
71
67.1
226
42.659
0.188
0.031
1.47
58.9
-1.52
100
5.0
0.0
80
206
71
67.1
227
42.847
0.188
0.031
1.48
58.8
-1.65
100
5.0
0.0
80
206
71
67.1
228
43.037
0.190
0.031
1.47
58.7
-1.42
101
4.9
-0.1
80
207
71
67.2
229
43.226
0.189
0.031
1.48
58.8
-1.57
100
4.9
0.0
80
207
71
66.9
230
43.414
0.188
0.031
1.48
58.7
-1.52
100
4.8
-0.1
80
207
71
67
231
43.602
0.188
0.031
1.47
58.8
-1.68
100
4.8
0.0
80
208
71
67.1
232
43.790
0.188
0.031
1.48
58.8
-1.67
100
4.8
0.0
80
207
71
67.1
233
43.979
0.189
0.032
1.47
58.9
-1.68
98
4.7
0.0
80
205
71
67
234
44.167
0.188
0.031
1.48
59
-1.58
100
4.7
0.0
80
206
71
67
235
44.357
0.190
0.032
1.47
59.1
-1.46
99
4.7
0.0
80
207
70
67
236
44.545
0.188
0.032
1.47
59.1
-1.43
98
4.6
0.0
80
205
70
67.1
237
44.732
0.187
0.031
1.47
59.1
-1.66
99
4.6
-0.1
80
208
70
66.9
PFS-TECO
Page 16 of 32
Summary of Contents for KP5522
Page 11: ...Project 22 753 Model KP5522 Page 10 Appliance Front Appliance Left...
Page 12: ...Project 22 753 Model KP5522 Page 11 Appliance Right Appliance Rear...
Page 14: ...Project 22 753 Model KP5522 Page 13 Pellet Fuel Analysis...
Page 17: ...Project 22 753 Model KP5522 Page 16 Sealed Unit...
Page 54: ......
Page 55: ......
Page 56: ......
Page 58: ...Project 22 751 Model Charnwood Skye E700 Page 16 Tunnel Schematic...
Page 102: ......
Page 103: ......
Page 104: ......
Page 129: ...2022 United States Stove Company 25 NOTES...
Page 177: ...2022 United States Stove Company 25 NOTES...
Page 272: ...24 2022 United States Stove Company NOTES...
Page 308: ......
Page 309: ......
Page 311: ......
Page 312: ......
Page 318: ......
Page 319: ......