IMPORTANT SAFETY INFORMATION
CONTINUED
13. Keep appliance area clear and free from combustible materials, gasoline and other flammable
vapors and liquids.
15. Any safety screen or guard removed for servicing, must be replaced prior to heater operation.
16. This vent-free gas heater is intended to be smokeless. If logs appear to smoke, turn off the
heater and call a qualified service person. Initial burn off may cause slight smoke and odor
during the first four hours of operation.
17. Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. For elevations
above 2,000 feet, input ratings should be reduced 4 percent per 1,000 feet above sea level.
Refer to the National Fuel Gas Code.
18. The appliance and its appliance main gas shut off valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressures in excess of 1/
2 psig (3.5 kPa).
19. The appliance must be isolated from the gas supply piping system by closing its equipment
shut off valve during any pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psig (3.5 kPa).
20. Do not use this heater if any part has been under water. Immediately call a qualified service
technician to inspect the room heater and to replace any part of the control system and any
gas control that has been under water.
4
Features:
Features:
Features:
Features:
Features:
• Heating Efficiency - 99.9%
• Wide BTU Range: 27,000-39,900.
• Safe Operation -
Oxygen Depletion Sensor (ODS).
• Fibre Ceramic Logs.
• 120 CFM Blower
• Push-Button Piezo Ignitor.
• Clean Operation.
• Easy Operation.
• Heats up to 1,200 square feet.
• Optional Remote Control, Wall Switch
and Wall Thermostat Kits
PRODUCT FEATURES
9947 Vent-free Gas Pedestal Heater
9947 Vent-free Gas Pedestal Heater
9947 Vent-free Gas Pedestal Heater
9947 Vent-free Gas Pedestal Heater
9947 Vent-free Gas Pedestal Heater
Figure 1.
Figure 1.
Figure 1.
Figure 1.
Figure 1.