OPERATION

Controlled combustion is the most efficient technique for wood heating because it enables you to select the 

type of combustion you want for each given situation. The wood will burn slowly if the wood furnace air intake 

control’s are adjusted to reduce the oxygen supply in the combustion chamber to a minimum. On the other hand, 

wood will burn quickly if the air control’s are adjusted to admit a larger quantity of oxygen in the combustion 

chamber. Real operating conditions may give very different results than those obtained during testing according 

to the species of wood used, its moisture content, the size and density of the pieces, the length of the chimney, 

altitude and outside temperature.

RELOADING

Once you have obtained a good bed of embers, you should reload the unit. In order to do so, open the air 

controls to maximum a few seconds prior to opening the furnace’s door.  Then proceed by opening the door 

very slowly. Then bring the red embers to the front of the furnace and reload the unit. For optimal operation of 

your wood furnace, we recommend you to operate it with a wood load approximately equivalent to the 3/4 of 

the height of fire bricks. It is important to note that wood combustion consumes ambient oxygen in the room. In 

the case of negative pressure, it is a good idea to allow fresh air in the room, either by opening a window slightly 

or by installing a fresh air intake system on an outside wall.

Creosote - Formation and Need for Removal - When wood is burned slowly, it produces tar and other organic 

vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively 

cool  chimney  flue  of  a  slow-burning  fire.  As  a  result,  creosote  residue  accumulates  on  the  flue  lining.  When 

ignited, this creosote makes an extremely hot fire. The chimney connector and chimney should be inspected at 

least twice monthly during the heating season to determine if a creosote build-up has occurred. If creosote has 

accumulated (3mm or more), it should be removed to reduce the risk of a chimney fire.

We strongly recommend that you install a magnetic thermometer on your smoke exhaust pipe, approximately 

18” above the furnace. This thermometer will indicate the temperature of your gas exhaust fumes within the 

smoke exhaust system. The ideal temperature for these gases is somewhere between 275°F and 500°F. Below 

these temperatures, the build-up of creosote is promoted. Above 500 degrees, heat is wasted since a too large 

quantity is lost into the atmosphere.

OPERATION AFTER LOSS OF ELECRICAL POWER 

This unit is not intended to be operated during power outage situations. If there is a power outage while the unit 

is being fired, do not add more wood, close all air controls to there minimum setting, and remove the air filter. Do 

not fire the unit again until power has been restored.

TO PREVENT CREOSOTE BUILD UP

Always burn dry wood. This allows clean burns and higher chimney temperatures, therefore less creosote deposit.

Leave the air control full open for about 5 min. every time you reload the furnace to bring it back to proper 

operating temperatures. The secondary combustion can only take place if the firebox is hot enough.

Always check for creosote deposit once every two months and have your chimney cleaned at least once a 

year. If a chimney or creosote fire occurs, close all dampers immediately. Wait for the fire to go out and the 

heater to cool, then inspect the chimney for damage. If no damage results, perform a chimney cleaning to 

ensure there is no more creosote deposits remaining in the chimney.

ASH DISPOSAL

Whenever ashes get 3 to 4 inches deep in your firebox or ash pan, and when the fire has burned down and 

cooled,  remove  excess  ashes.  Leave  an  ash  bed  approximately  1  inch  deep  on  the  firebox  bottom  to  help 

maintain a hot charcoal bed.

Ashes should be placed in a metal container with a tight-fitting lid. The closed container of ashes should be 

placed on a noncombustible floor or on the ground, away from all combustible materials, pending final disposal. 

The ashes should be retained in the closed container until all cinders have thoroughly cooled.

If there is a soot or creosote fire:

• 

Establish a routine for the storage of fuel, care for the appliance and firing techniques.

• 

Check daily for creosote buildup until experience shows how often cleaning is necessary.

WARNINGS:

• 

Never over fire your furnace. If any part of the furnace starts to glow red, over firing is happening. Readjust 

the air intake control at a lower setting.

• 

The installation of a log cradle or grates is not recommended in your wood furnace. Build fire directly on 

firebrick.

• 

Never put wood above the firebrick lining of the firebox.

Summary of Contents for ASHLEY AF1600E

Page 1: ...States Stove Company 227 Industrial Park Rd South Pittsburg TN 37380 853106 0301H U S ENVIRONMENTAL PROTECTION AGENCY Certified to comply with the 2017 particulate emission standards Not approved for...

Page 2: ...on Agency s emission limits for wood heaters sold after May 15 2016 Under specific EPA test conditions this heater has been shown to deliver heat at a rate of 33 438 to 77 456 BTU hr This heater achie...

Page 3: ...to ignite the fire Do not leave the furnace unattended when the door is slightly opened Do not burn garbage flammable fluid such as gasoline naphtha or motor oil Always close the door after the ignit...

Page 4: ...er return fresh air ductwork and supply air ductwork This furnace may be installed as a stand alone wood furnace See kit installation section in this manual to ensure proper assembly installation and...

Page 5: ...s adequate room to preform maintenance and service your furnace DO NOT store fuel within the specified clearances The clearances will change depending on what kits are installed with your furnace See...

Page 6: ...ir plenum is to have a minimum height of 24 610mm if the top of the first vertical section is not flush with the top of the first horizontal section of ductwork If the top of the plenum is flush with...

Page 7: ...sc 3 Remove blowers from cartons Remove junction box cover Attach clip nuts as in figure shown Install blower s and gasket s with 1 4 20 x 3 4 bolts as shown 4 Wire right side blower first See wiring...

Page 8: ...H BLACK Makes no difference which leads from the motor s connects to the corresponding leads coming out of the conduit All electrical connections should be done by a qualified electrician It is recomm...

Page 9: ...washers to attach the new air slides to your unit IMPORTANT The 6 six 1 4 20 lock nuts springs and washers must be installed in the same order as they were removed first the washer then the spring an...

Page 10: ...locate the placement of the actuator NOTE When locating the position of the actuator insert the servo arm into the actuator as shown Use 3 three 10 x 500 screws to attach the actuator to the unit STEP...

Page 11: ...FM Blower 2 Gasket Blower 8 Tinnerman Clip 1 4 20 8 1 4 20 x 3 4 Bolt 2 Conduit Assembly 5ft 1 Honeywell Limit Control 1 Conduit Assembly 1ft 1 Junction Box 1 Insulation 5 x 5 1 Rocker Switch 1 Romex...

Page 12: ...rior chimney will be hotter than an exterior chimney that is being cooled by the ambient air outside the house Therefore the gas which circulates will cool slower thus reducing the build up of creosot...

Page 13: ...ctor and a minimum 24 gauge ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fiberglass...

Page 14: ...the furnace pipe should never exceed 8 to 10 2 4m to 3 04 m Except for cases of vertical installation cathedral roof style where the smoke exhaust system can be much longer and connected without prob...

Page 15: ...surface from the ground and under a cover or covered area from rain or snow also accelerates drying time A good indicator if wood is ready to burn is to check the piece ends If there are cracks radia...

Page 16: ...meter should be split The wood should not be stored directly on the ground Air should circulate through the cord A 24 to 48 air space should be left between each row of logs which should be placed in...

Page 17: ...he instructions outlined in this manual and the proper power is supplied to it 2 Open the fuel loading door Note If there already is a bed of hot glowing coals in the combustion chamber proceed direct...

Page 18: ...s exhaust fumes within the smoke exhaust system The ideal temperature for these gases is somewhere between 275 F and 500 F Below these temperatures the build up of creosote is promoted Above 500 degre...

Page 19: ...learn the burn characteristic of you appliance and burn well seasoned wood Higher burn rates are not always the best heating burn rates after a good fire is established a lower burn rate may be a bet...

Page 20: ...2 diameter rope gasket PAINT Only clean your furnace with a dry soft cloth that will not harm the paint finish If the paint becomes scratched or damaged it is possible to give your wood furnace a bra...

Page 21: ...ents will void the warranty Moisture Meter 80697 1 Wooden Knob Assembly 892767 2 Air Slide Small 610624 1 Back Panel 28067 1 Port Support 28027 1 Gasket Flue Collar 88032 1 Door Latch C000022 23786 1...

Page 22: ...er Junction Box 80231 1 4 X 4 Junction Box 80131 1 Weldment Cabinet Top 610581 1 Right Brick Retainer 28061 1 Blower Assembly 80600 2 Supply Cord 80232 1 Fan Cntrl Cord Assy 68231 3 In order to mainta...

Page 23: ...ront Filler 28064 1 Assembly Ash Door 610496 1 5 8 Rope Gasket 88066 3ft 1 8 Dia X 1 1 2 Cotter Pin 83874 6 Conduit Assy 68859 1 In order to maintain warranty components must be replaced using origina...

Page 24: ...ty components will void the warranty Servo Bracket 28433 1 4X4 Fan Box 25625 1 Fan Center 80130 1 Hook Handle 25748 1 Insulation 5 x5 25626 1 120V Erie Motor 80592 1 Firebrick 4 5 X 7 5 892945 1 Terti...

Page 25: ...mpany ________________________________________ Telephone No ______________________________________ Stove Inspected Chimney Swept Items Replaced ____________________________________ Service 05 Date ___...

Page 26: ...terruptions or uctuations of electrical power supply to the appliance Non USSC venting components hearth components or other accessories used in conjunction with the appliance USSC s obligation under...

Page 27: ...ces de rechange Veuillez conserver ce guide dans un endroit s r des fins de r f rence Lorsque vous nous crivez veuillez indiquer le num ro complet du mod le qui figure sur la plaque signal tique de l...

Page 28: ...autoris es et approuv es par crit par USSC et ou 9 les interruptions ou uctuations de l alimentation lectrique de l appareil Composants d vacuation des gaz composants de l tre ou accessoires utilis s...

Page 29: ...ant les r glementations f d rales Unite Company garantit uniquement l acheteur au d tail original que exempt de d fectuosit s des mat riaux et de qualit de l ex cution pen indiqu e ci dessous de la da...

Page 30: ...d air 28431 1 Contr le de limite 80145 1 Glissi re d air principale 28437 1 Bras de servo 610745 1 Bras de servo 892891 1 Poign e s parable 28432 1 Outil de grille de secoueur 610744 1 Pi ces De Rech...

Page 31: ...28064 1 Assemblage porte en fr ne 610496 1 Joint de corde de 5 8 88066 3ft 1 8 Dia X 1 1 2 goupille fendue 83874 6 Doublure de canal 28319 2 Pour conserver la couverture de la garantie les composants...

Page 32: ...ion 4 X 4 80131 1 Soudure sup rieure du meuble 610581 1 Retenue de brique droite 28061 1 Ensemble de soufflerie 80600 2 Cordon d alimentation 80232 1 Cordon de commande de ventilateur assy 68231 3 Pou...

Page 33: ...Soudure entr e d air 610582 1 paule gauche 28053 1 Manche en bois W3100 02 2 Collier de chemin e 6 C I 40246 1 Collier de talon 8 891214 1 Loquet de porte 86626 1 Amortisseur 610583 1 paule droite 28...

Page 34: ...le remplacement Lors du remplacement de la vitre le joint d tanch it de la vitre devrait aussi tre remplac pour s assurer que la vitre est bien tanche Ne jamais laver la vitre avec des produits risqua...

Page 35: ...voir calorifique sup rieur c est lorsque l eau quitte le processus de combustion sous forme enti rement condens e Dans le cas des po les bois ceci voudrait dire que les gaz d vacuation sont la temp ra...

Page 36: ...chemin e Nous vous recommandons fortement d installer un thermom tre magn tique sur le tuyau d vacuation des fum es environ 18 po au dessus de l appareil de chauffage Ce thermom tre vous indiquera la...

Page 37: ...petit bois d allumage l avant de la chambre de combustion directement sur les briques r fractaires 4 tendre quelques feuilles de papier journal torsad es par dessus le bois d allumage 5 Placer d autr...

Page 38: ...Enti rement ferm Amortisseur d air tertiaire Enti rement ferm Amortisseur d air primaire Enti rement ferm Amortisseur d air tertiaire Enti rement ferm Amortisseur d air primaire Contr le D air Alterna...

Page 39: ...hes d une corde Un espace libre de 60 120 cm 24 48 po doit tre laiss entre les rang es de b ches lesquelles on placera dans un endroit bien ensoleill La couche de bois du dessus d une corde doit tre p...

Page 40: ...e la neige acc l rera le temps de s chage Un bon indicateur pour savoir si le bois est pr t br ler est de v rifier les extr mit s du morceau Si elles sont fendues de toutes parts partir du centre le b...

Page 41: ...ond de la pi ce L installation du syst me d vacuation de la fum e ne doit pas comporter plus de deux coudes de 90 degr s Il est interdit d installer un stabilisateur de tirage barom trique registre de...

Page 42: ...bustibles muraux Utiliser des supports en t le solidement fix s aux surfaces murales de tous les c t s pour garder un espace d air de 228 6 mm 9 po Lors de la fixation des supports la longueur de la c...

Page 43: ...s quent le gaz qui circule est refroidi plus lentement r duisant ainsi l accumulation de cr osote et les risques d incendie de chemin e Le tirage caus par la tendance de l air chaud monter est plus fo...

Page 44: ...fl eur 8 Clip de tinnerman 1 4 20 8 1 4 20 x 3 4 boulon 2 Assembl e de conduit 5ft 1 Contr le de limite de Honeywell 1 Assembl e de conduit 1ft 1 Bo te de jonction 1 Isolation 5 x 5 1 Interrupteur bas...

Page 45: ...ervo affleure le haut de l actionneur avant de le fixer TAPE 8 Mesurez 14 du sol au bas du support servo pour localiser le positionnement de l actionneur REMARQUE Lorsque vous localisez la position de...

Page 46: ...ment retir s pour fixer les nouveaux glissi res air votre unit IMPORTANT Les six 6 contre crous ressorts et rondelles 1 4 20 doivent tre install s dans le m me ordre que celui o ils ont t retir s d ab...

Page 47: ...i Il est recommand de brancher l appareil de chauffage sur son propre circuit de 15 A 120 V de l alimentation de la maison SOL MOTEUR DE LA SOUFFLANTE MOTEUR DE LA SOUFFLANTE IMPORTANT LE C BLAGE D AL...

Page 48: ...de 1 4 20 x 3 4 tel qu illustr 4 Raccordez d abord la soufflante droite voir le sch ma de c blage et replacez le couvercle sur la bo te de jonction de la soufflante 5 C blez la soufflante gauche comme...

Page 49: ...tion de cet appareil de chauffage le pl num d air chaud doit avoir une hauteur minimale de 24 po 610 mm si le haut de la premi re section verticale n est pas la m me hauteur que le haut de la premi re...

Page 50: ...uffage Ne pas entreposer le carburant dans l espace de d gagement sp cifi Les d gagements varient selon les ensembles compl mentaires install s avec l appareil de chauffage Voir les tableaux et le dia...

Page 51: ...imentation de conduits de reprise d air air frais et de conduits d arriv e d air Ce four peut tre install comme un four bois autonome Voir la section sur l installation d ensembles de ce manuel et de...

Page 52: ...e est une liste des outils et des mat riaux n cessaires l installation de votre appareil de chauffage Cl douilles de 7 16 po Douille de 5 16 po utilisez id alement une perceuse lectrique et un adaptat...

Page 53: ...de chargement du combustible doit tre laiss e entrouverte pendant 10 secondes avant de l ouvrir compl tement Charger le carburant avec pr caution pour viter tout dommage Pour les installations canadie...

Page 54: ...h s s ch s l air par rapport aux r sineux ou aux bois durs verts ou fra chement coup s Ce po le bois a besoin d une inspection et d une r paration p riodiques pour fonctionner correctement Il est cont...

Page 55: ...uffage Respectez tous les codes locaux et nationaux lors de l installation de cet appareil Cet appareil ne doit pas tre raccord un conduit de chemin e desservant un autre appareil Cet appareil est con...

Page 56: ...pany 227 Industrial Park Rd South Pittsburg TN 37380 U S ENVIRONMENTAL PROTECTION AGENCY Certified to comply with the 2017 particulate emission standards Not approved for sale after May 15 2020 Report...

Reviews: