background image

-14-

CHIMNEY DRAFT

NOTE:  A  DRAFT  READING  OF  0.05[12.45]  to  0.06[14.94] 

(Water  Column[Pascals])  IS  REQUIRED  FOR  PROPER 

BURNING OF THIS APPLIANCE.

Draft  is  a  function  of  the  chimney,  NOT  THE  APPLIANCE 

— Do not expect the appliance to draw. Smoke spillage 

into  the  house  or  excess  buildup  of  condensation  or 

creosote in the chimney are warnings that the chimney 

is NOT functioning properly. Correct the problem before 

using the appliance. Following are some possible causes 

for improper draft.

1.  The connector pipe may be pushed into the chimney too far, stopping the draft.
2.  If the chimney is operating too cool, water will condense in the chimney and run back into the appliance. 

Creosote formation will be rapid and may block the chimney. Operate the appliance at a fire level high 

enough to keep the chimney warm preventing this condensation.

3.  If the fire burns well but sometimes creates excessive smoke or burns slowly, it may be caused by the chimney 

top being lower than another part of the house or a nearby tree. The wind blowing over a house or tree falls on 

top of the chimney like water over a dam, beating down the smoke. The top of the chimney should be at least 

three (3) feet above the roof and be at least two (2) feet higher than any point of the roof within ten (10) feet.

ASH REMOVAL AND DISPOSAL

Whenever ashes get 3 to 4 inches deep in your firebox or ash pan, and when the fire has burned down and cooled, 

remove excess ashes. Leave an ash bed approximately 1 inch deep on the firebox bottom to help maintain a hot 

charcoal bed. Ashes should be placed in a metal container with a tight-fitting lid. The closed container of ashes 

should be placed on a non-combustible floor or on the ground, away from all combustible materials, pending 

final disposal. The ashes should be retained in the closed container until all cinders have thoroughly cooled.

SMOKE AND CO MONITORS

Burning  wood  naturally  produces  smoke  and  carbon  monoxide(CO)  emissions.  CO  is  a  poisonous  gas  when 

exposed  to  elevated  concentrations  for  extended  periods  of  time.  While  the  modern  combustion  systems  in 

heaters drastically reduce the amount of CO emitted out the chimney, exposure to the gases in closed or confined 

areas can be dangerous. Make sure your stove gaskets and chimney joints are in good working order and sealing 

properly to ensure unintended exposure. It is recommended that you use both smoke and CO monitors in areas 

having the potential to generate CO. 

GLASS CARE

The following usage and safety tips should be observed:

1.  Inspect the glass regularly for cracks and breaks. If you detect a crack or break, extinguish the fire immediately 

and contact the manufacturer for a replacement.

2.  Do not slam the door or otherwise impact the glass. When closing doors, make sure that logs or other objects 

do not protrude to impact the glass.

3.  Do not build fires against (or that might fall against) the glass.
4.  Do not clean the glass with materials that may scratch (or otherwise damage) the glass. Scratches on the 

glass can develop into cracks or breaks during operation.

5.  Never attempt to clean the glass while the unit is hot. If deposits are not very heavy, normal glass cleaners are 

adequate using a soft, non-abrasive cleaning pad. Heavier deposits may be removed with oven cleaners.

6.  Never put substances which can ignite explosively in the unit. Even small explosions in confined areas can 

blow out the glass.

CAUTIONS:

• 

ASHES COULD CONTAIN HOT EMBERS EVEN AFTER TWO DAYS WITHOUT OPERATING THE STOVE.

• 

THE ASH PAN CAN BECOME VERY HOT. WEAR GLOVES TO PREVENT INJURY.

• 

NEVER BURN THE STOVE WITH THE ASH TRAP OPEN. THIS WOULD RESULT IN OVER FIRING THE STOVE. DAMAGE 

TO THE STOVE AND EVEN HOUSE FIRE MAY RESULT.

Summary of Contents for Ashley AW1820E

Page 1: ...p in a safe place for future reference U S Environmental Protection Agency Certified to comply with 2020 particulate emissions standards CALIFORNIA PROPOSITION 65 WARNING This product can expose you to chemicals including carbon monoxide which is known to the State of California to cause cancer birth defects and or other reproductive harm For more information go to www P65warnings ca gov Ce produi...

Page 2: ...a UL 103 HT U S Listed Residential Type and Building Heating Appliance Chimney Use a 6 diameter chimney that is high enough to create sufficient draft 11 Be sure your chimney is safely constructed and in good repair Have the chimney inspected by the fire department or a qualified inspector Your insurance company should be able to recommend a qualified inspector 12 Creosote or soot may build up in ...

Page 3: ...ining Systems for Existing Masonry or Factory Built Chimneys and Vents or CAN ULC S640 Standard for Lining Systems for New Masonry Chimneys 24 Permanently seal any opening between the masonry of the fireplace and the facing masonry 25 Fireplace insert surround panels may be removed to inspect fireplace insert and fireplace 26 U S Stove Company requires installing smoke detectors in the same room a...

Page 4: ...lacement if the appliance is ever removed The removal of any parts that render the fireplace unusable for burning solid fuel requires a permanent label to be affixed by the installer that states the fireplace is unsuitable for burning solid fuel unless the missing parts are replaced and the fireplace is restored to its original certified condition 4 Chimney Caps Mesh type chimney caps and spark ar...

Page 5: ...ing fuel fired equipment shows evidence of back puffing smoke roll out inefficient operation or excessive smell in the living area b Opening a window or door alleviates any of the above problems or symptoms c The building is constructed with a well sealed vapor barrier tight fitting windows or has powered exhaust fans d Excessive condensation on windows in the winter e The building has a ventilati...

Page 6: ...me with a metal warning label Permanently attach the warning plate to a visible location in the fireplace After choosing a visible location in the fireplace permanently attach the warning plate by screwing or nailing it into place Note Use the holes in the label to mark and predrill the holes needed for attaching the label 6 Position the appliance into the fireplace opening until the top lip of th...

Page 7: ...f your stove and radiates heat more evenly If firebricks were removed to position appliance replace them before firing appliance See figure 7 for proper orientation and positioning Install the back row first then sides and finally install bottom firebricks 1 14 2 6 5 7 8 3 4 9 10 11 12 13 SURROUND ASSEMBLY VIEW FROM BACK SPRING SURROUND Slots in surround slide of firebox top Figure 6 Surround Inst...

Page 8: ... must meet the three minimum height requirements detailed in figure 8 A minimum draft of 0 05 w c measured in water column is required for proper drafting to prevent back puffing smoke spillage and to maximize performance Gauges to measure draft are readily available at stove stores and are economical to rent or purchase Factors such as wind barometric pressure trees terrain and chimney temperatur...

Page 9: ...ons Under extreme conditions it may rot instead of drying This point cannot be over stressed the vast majority of the problems related to the operation of a wood stove is caused by the fact that the wood used was too damp or had dried in poor conditions These problems can be ignition problems creosote build up causing chimney fires low energy yield blackened windows incomplete log combustion Small...

Page 10: ... chemicals or waste in this appliance could result in damages to the heater or result in bodily injury It will also void any warranty on the appliance This heater is designed to burn natural wood only Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods as compared to softwoods or to green or freshly cut hardwoods DO NOT BURN 1 Garbage 2 Lawn clippings...

Page 11: ...the best heating burn rates after a good fire is established a lower burn rate may be a better option for efficient heating A lower burn rate slows the flow of usable heat out of the home through the chimney and it also consumes less wood NOTICE INITIAL BURNS TO CURE PAINT BECAUSE OF THE HIGH OPERATING TEMPERATURES THIS APPLIANCE IS COATED WITH A SPECIAL HIGH TEMP PAINT WHICH REQUIRES A SERIES OF ...

Page 12: ...iance overfiring is when any part of the appliance s exterior or chimney connections glow 5 Close the feed door and secure tightly 6 Adjust the air inlet control as described in the Fueling Instruction section of this manual 7 Empty ashes regularly Do not allow ashes to pile up Properly dispose of hot ashes see the Ash Removal And Disposal section of this manual After the first high burn load and ...

Page 13: ...ing green wood may cause excessive creosote build up Ignition of creosote or overfiring could cause a chimney fire Chimney fires burn extremely hot and may ignite surrounding combustible materials In case of a chimney fire call the fire department immediately CREOSOTE FORMATION AND REMOVAL When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to f...

Page 14: ...final disposal The ashes should be retained in the closed container until all cinders have thoroughly cooled SMOKE AND CO MONITORS Burning wood naturally produces smoke and carbon monoxide CO emissions CO is a poisonous gas when exposed to elevated concentrations for extended periods of time While the modern combustion systems in heaters drastically reduce the amount of CO emitted out the chimney ...

Page 15: ...ut from glass clip 4 Remove old gasket and clean glass 5 Replace new gasket starting at the bottom of glass working along edges being sure to center gasket channel on glass 6 Trim to length and butt ends together 7 Replace glass into door being sure not to overtighten screw and clip After extensive use the gasket material which provides glass and door seal may lose it s resiliency and will need to...

Page 16: ... CORD NEAR OR ACROSS HOT SURFACES CAUTION THE BLOWER ASSEMBLY MUST BE DISCONNECTED FROM THE SOURCE OF ELECTRICAL SUPPLY BEFORE ATTEMPTING ANY MAINTENANCE MALE BLACK BLACK BLACK WHITE BLACK WHITE MALE BLOWER MOTOR SUPPLY CORD BLOWER RHEOSTAT ATTACH TO BACK OF BLOWER HOUSING MALE ...

Page 17: ...6 2 3 12 11 IN ORDER TO MAINTAIN WARRANTY COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY Key Part Description Qty 11 892294 Hinge Pin 2 12 40571 Hinge Block 2 13 83913 Extension Spring 2 14 26269 Top Surround 1 15 26270 Side Surround 2 16 891992 1 Surround ...

Page 18: ...29228 Bottom Glass Retainer 1 In Order To Maintain Warranty Components Must Be Replaced Using Original Manufacturers Parts Purchased Through Your Dealer Or Directly From The Appliance Manufacturer Use Of Third Party Components Will Void The Warranty Key Part Description Qty 1 891414 Half Firebrick 2 2 89066 Firebrick 4 1 2 x 9 9 3 891989 2 Firebrick 1 1 4 x 2 1 4 1 4 893010 Half Firebrick Notched ...

Page 19: ... 19 Notes ...

Page 20: ...e 07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _________________________________ Stove Inspected Chimney Swept Items Replaced ________________________________ Service 02 Date _____________________ Engineer Name ________________________________ License No ______...

Page 21: ...ultérieure Lors d une correspondance donnez toujours le numéro de modèle complet qui est inscrit sur la plaque attachée à l appareil de chauffage Lors de la commande de pièces de rechange donnez toujours les informations dans l ordre suivant 1 The part number Le numéro de pièce_________________________________________________ 2 The part description La description de la pièce_______________________...

Page 22: ..._____________________________ Service de 07 Date _____________________ Nom de l ingénieur ____________________________ N de licence _________________________________ Compagnie ___________________________________ N de téléphone _______________________________ Poêle Inspecté Cheminée balayée Articles Remplacé _____________________________ Service de 02 Date _____________________ Nom de l ingénieur _...

Page 23: ...n de rouleau 1 6 40883 Porte cintrée moyenne 1 7 88324 Joint de corde de 1 po 5 ft 8 893159 Verre propre 1 9 29229 Retenue de verre latérale 2 10 29227 Retenue en verre supérieure 1 11 29230 Pince de joint 1 12 29228 Retenue de verre inférieure 1 Clé Partie Description Qté 1 891414 Demi brique réfractaire 2 2 89066 Brique réfractaire 4 1 2 x 9 9 3 891989 2 Brique réfractaire 1 1 4 x 2 1 4 1 4 8930...

Page 24: ... 4 611008 Cabinet droit 1 5 893261 Glissière d amortisseur 1 6 29301 Accolade coulissante 2 7 893261 Manche en bois 1 8 29300 Couverture 1 9 29298 Amortisseur 1 10 611007 Cabinet gauche 1 10 1 13 8 15 16 18 19 17 14 9 7 4 5 6 2 3 12 11 Clé Partie Description Qté 11 892294 Axe De Charnière 2 12 40571 Bloc De Charnière 2 13 83913 ressort d extension 2 14 26269 contour supérieur 1 15 26270 bordure la...

Page 25: ... sur des surfaces chaudes Mise en garde Le ventilateur doit être déconnecté de la source d alimentation électrique avant de tenter toute opération de maintenance Mâle Noire Noire Noire Blanche Noire Blanche Mâle Moteur de la soufflante Cordon d alimentation Rhéostat souffleur Fixation au boîtier du ventilateur Mâle ...

Page 26: ...étanchéité correcte si les cordons deviennent effilochés ou usés remplacez les tout de suite La porte ce cette unité utilise un joint de corde de 1 po de diamètre LE REMPLACEMENT DU CORDON D ÉTANCHEITÉ DE LA PORTE La porte de cet appareil utilise un joint de corde de 1 de diamètre 1 Assurez vous que l appareil n est pas utilisé et a bien refroidi 2 Enlevez le vieux cordon d étanchéité de la porte ...

Page 27: ...roduit naturellement des émissions de fumée et du monoxyde de carbone CO Le CO est un gaz poison lorsque l exposition se fait à des concentrations élevées pour une période de temps prolongée Bien que les systèmes de combustion modernes des chauffages réduisent de façon importante la quantité de CO émis par la cheminée l exposition aux gaz dans des endroits fermés ou clos peut être dangereuse Assur...

Page 28: ...lorifique dépassant les spécifications de conception du chauffage peut lui causer des dommages permanents ainsi qu au catalyseur de postcombustion s il est présent 7 Videz les cendres régulièrement Ne laissez pas les cendres s accumuler Éliminez correctement les cendres chaudes voir la section Enlèvement et élimination des cendres de ce manuel 8 Brûlez de petits feux intenses au lieu de grands feu...

Page 29: ...s rouler et heurter la vitre REMARQUE Ne surchauffez pas l appareil une surchauffe se produit lorsqu une partie des connexions extérieures ou de la cheminée de l appareil brille 5 Fermez la porte d alimentation et fixez la fermement 6 Réglez la commande d entrée d air comme décrit dans la section Instructions de remplissage de ce manuel Après la première charge de combustion élevée et le poêle bie...

Page 30: ...n bon feu un taux de combustion inférieur peut être une meilleure option pour un chauffage efficace Un taux de combustion inférieur ralentit le flux de chaleur utilisable hors de la maison par la cheminée et il consomme également moins de bois NOTIFICATION LES PREMIERS FEUX POUR SÉCHER LA PEINTURE À CAUSE DES HAUTES TEMPÉRATURES ATTEINTES LORS DU FONCTIONNEMENT CET APPAREIL EST REVÊTU D UNE PEINTU...

Page 31: ...bles résultent généralement lors de la combustion de bois durs séchés séchés à l air par rapport aux résineux ou aux bois durs verts ou fraîchement coupés NE PAS BRÛLER 1 Des ordures 2 Coupures de gazon ou déchets de jardinage 3 Matériaux contenant du caoutchouc y compris des pneus 4 Matériaux contenant du plastique 5 Déchets de produits pétroliers peintures ou diluants à peinture ou produits d as...

Page 32: ... même pourrir au lieu de sécher On ne saurait trop souligné que la vaste majorité des problèmes liés au fonctionnement d un insert à bois est causée par le fait que le bois utilisé était trop humide ou avait séché dans de mauvaises conditions Ces problèmes peuvent être problèmes d allumage accumulation de créosote causant des incendies de cheminée rendement énergétique bas fenêtres noircies combus...

Page 33: ...lages de dos les déversements de fumée et pour maximiser les performances Des jauges pour mesurer le tirage sont facilement disponibles dans les magasins de poêles et sont économiques à louer ou à acheter Des facteurs tels que le vent la pression barométrique les arbres le terrain et la température de la cheminée peuvent avoir un effet négatif sur le tirage Le fabricant ne peut être tenu responsab...

Page 34: ...llumer l appareil Voir figure 7 pour la bonne orientation et le positionnement correct Installez en premier la rangée de briques située à l arrière suivie par celle de chaque côté et enfin les briques réfractaires situées entre chaque côté 1 14 2 6 5 7 8 3 4 9 10 11 12 13 SURROUND ASSEMBLY VIEW FROM BACK ASSEMBLAGE DE L HABILLAGE VUE DE DERRIÈRE SPRING SURROUND Slots in surround slide of firebox t...

Page 35: ...arquer et pré percer les trous nécessaires pour fixer l étiquette 7 Positionnez l appareil dans l ouverture du foyer jusqu à ce que la lèvre supérieure de la chemise d air soit alignée avec la façade du foyer 8 Nivelez l appareil en ajustant les vis à l arrière de l appareil 9 Connectez le conduit gaine de cheminée à l appareil en utilisant un adaptateur en acier inoxydable installé à l aide d un ...

Page 36: ...met de la cheminée est exigé Un adaptateur en acier inoxydable est recommandé pour attacher la gaine conduit d acier inoxydable à la buse La partie mâle ou ondulée de l adaptateur doit être installée à l intérieur de la buse pour permettre à la condensation ou la créosote présente dans la gaine conduit de retourner dans l insert La gaine conduit de cheminée et ou les adaptateurs doivent être attac...

Page 37: ...ivent être stockées précautionneusement si l appareil est déplacé Le démontage de n importe quelle pièce qui rend la cheminée inutilisable pour brûler des combustibles solides implique qu une étiquette permanente soit apposée par l installateur afin d indiquer que l insert n est plus approprié pour brûler des combustibles solides à moins que les pièces manquantes soient replacées et la cheminée re...

Page 38: ...forme aux spécifications CAN ULC S635 Classe 3 norme pour les conduits existants de cheminées industrielles ou de maçonnerie ou CAN ULC S640 norme pour les conduits de nouvelles cheminées de maçonnerie 24 Scellez de façon permanente toute ouverture entre la maçonnerie du foyer et la maçonnerie de façade 25 L insert ou les panneaux d habillage doivent pouvoir être enlevés pour permettre l inspectio...

Page 39: ...ans une autre pièce un espace confiné le grenier ou à l intérieur d un bâtiment Ne connectez pas cet appareil à un conduit de cheminée déjà utilisé par un autre appareil 10 NE connectez pas un appareil de chauffage au bois à un évent à gaz en aluminium de Type B Ceci n est pas sûr Utilisez un conduit de cheminée conforme aux normes en vigueur Utilisez un conduit de cheminée de 15 cm de diamètre et...

Page 40: ...rs pour plus d informations sur les conditions d installation et les restrictions N utilisez pas cet appareil dans un mobile home une maison préfabriquée une caravane ou une tente U S Environmental Protection Agency Certifié pour se conformer aux normes d émissions de particules de 2020 AVERTISSEMENT CONCERNANT LA PROPOSITION 65 DE L ÉTAT DE LA CALIFORNIE Ce produit peut vous exposer à des agents ...