background image

-5-

H

D

J

E

CLEARANCE

 TO

 W

ALLS 

Side 

w

all

Bac

kw

all

F

F

Side 

w

all

Bac

kw

all

CORNER INS

TALL

ATION 

CLEARANCE

 TO

 W

ALLS

Cei

lin

g

CORNER INS

TALL

ATION 

CLEARANCE

 TO 

WALLS & CELING

G

D

H

DÉGAGEMENTS AVEC LES MATIÈRES COMBUSTIBLES

Il est 

extrêmement important 

que les 

dégagements avec 

les matières 

combustibles soient 

strictement respectés 

lors de 

l'installation du poêle. 

• 

Ne placez 

aucun matériau 

combustible à 

moins de 

4 pi 

(1,2 m) 

de 

l’avant de l’unité.

• 

Le jeu entre le conduit de fumée et un mur n’est valable que pour 

les murs verticaux et pour le conduit de fumée vertical.

• 

Le raccord 

de cheminée 

ne doit 

pas traverser 

un grenier 

ou un

 

toit, un 

placard ou 

un espace 

dissimulé similaire, 

un plancher 

ou 

un plafond.

• 

Pour les 

installations canadiennes, 

où le 

passage à 

travers un 

mur ou

 

une cloison 

de construction 

combustible est 

souhaité, l’installation

 

doit être conforme à la norme CAN / CSA-B365.

• 

Un conduit de fumée traversant un mur combustible doit avoir un

 

dégagement minimum de 18 po (457,2 mm).

• 

Pour réduire 

les dégagements 

des conduits 

de fumée 

par rapport

 

aux matériaux 

combustibles, contactez 

votre service 

de sécurité

 

local.

Clé

Dimensions

po

mm

D

Mur arrière au poêle

17

432

E

Paroi latérale au poêle

26

661

F

Mur à coin (installation en angle)

18

458

G

Hauteur de plafond

84

2134

H

Backwall to Flue

19

483

J

Flanc à conduit

35

889

EXIGENCES SPÉCIALES POUR LES MAISONS MOBILES (USA UNIQUEMENT)

AVERTISSEMENT! - Ne pas installer dans une chambre à coucher.

MISE EN GARDE! - L’intégrité structurelle du plancher, du mur et du plafond / toit de la maison mobile doit être maintenue.

En plus 

des exigences 

d’installation précédemment 

détaillées, les 

installations de 

maisons mobiles 

doivent répondre 

aux 

exigences suivantes:

• 

Le chauffe-eau 

doit être 

connecté à 

une cheminée 

préfabriquée conforme 

à la 

norme CAN 

/ ULC-S629, 

norme pour 

les 

cheminées préfabriquées à 650°C.

• 

Le radiateur 

doit être 

fixé en 

permanence au 

sol. Il y 

a deux 

trous dans 

la base 

du piédestal, 

utilisez des 

boulons de 

3/8 po 

à travers le plancher.

• 

Le radiateur 

doit être 

électriquement mis 

à la 

terre sur 

le châssis 

en acier 

de la 

maison mobile 

avec du 

fil de 

cuivre 8 

GA 

en utilisant une rondelle dentelée ou en étoile pour pénétre

r la peinture ou le revêtement protecteur 

pour assurer la mise 

à la terre.

• 

Lors du 

déplacement de 

votre maison 

mobile, toute 

ventilation extérieure 

doit être 

retirée pendant 

le déplacement 

de la 

maison mobile. Après la relocalisation, toute ventilation doit être réinstallée et solidement fixée.

• 

L’air extérieur est obligatoire pour l’installation dans une maison mobile. Consultez votre revendeur pour l’achat.

• 

Vérifiez auprès des responsables locaux de la construction car d’autres codes peuvent s’appliquer.

• 

Utilisez uniquement 

les composants 

spécifiés répertoriés 

dans ce 

manuel pour 

cet appareil. 

L’utilisation de 

composants qui 

ne sont pas destinés à cet appareil peut entraîner des conditions dangereuses.

INSTRUCTIONS D’ASSEMBLAGE DE L’AIR DE COMBUSTION (INSTALLATIONS DE MAISONS MOBILES - REQUISES)

Cet appareil nécessite une source d’air de combustion. Si votre maison est de construction 

étanche ou a des problèmes de 

pression négative, 

vous aurez 

besoin d’une 

source d’air 

extérieure. Vous 

trouverez ci-dessous 

une liste 

d’indicateurs possibles 

indiquant qu’une source d’air extérieur de combustion peut être requise.

Mur Arrière

Paroi Latérale

Paroi Latérale

Mur Arrière

Plafond

Dégagement d’installation 

d’angle aux murs et au 

plafond

Dégagement d’installation d’angle 

aux murs

Dégagement aux murs

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for ASHLEY AW3200E

Page 1: ...t de la Californie comme causant le cancer et des malformations cong nitales ou autres dommages au f tus Pour obtenir plus de renseignements veuillez consulter le site www P65warnings ca gov This manu...

Page 2: ...y claims Combustible Wood Colors Metallic Black Flue Pipe Diameter 6 153 mm Flue Pipe Type Standard Single Wall or Double Wall Black or Blued Steel 2100 F 650 C Minimum Chimney Height 12 3 7 m Maximum...

Page 3: ...s A to the center section B of skirting and secure with four 4 truss head screws 2 Attach the side skirting sections C D to the corner pieces and secure with four 4 truss head screws 3 Slide the U sha...

Page 4: ...SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IT IS IN USE IN THE EVENT OF A CHIMNEY FIRE PUSH THE AIR CONTROL FULL CLOSED TO DEPRIVE THE FIRE OF OXYGEN CALL THE FIRE DEPARTMENT DO NOT CONNECT TO ANY...

Page 5: ...r wire using a serrated or star washer to penetrate paint or protective coating to ensure grounding When moving your mobile home all exterior venting must be removed while the mobile home is being rel...

Page 6: ...ertified wood stove installer Drill a 5 hole through the wall at the desired point of entry The point of entry should be at or below the level of the intake air tube on the wood stove Slide the tail p...

Page 7: ...appliance and chimney connector joints An uncontrollable burn or excessive temperature indicates an excessive draft CHIMNEY Your wood stove may be hooked up with a 6 factory built or masonry chimney...

Page 8: ...anufacturer The chimney must be the required height above the roof or other obstructions for safety and proper draft operation MASONRY CHIMNEY Ensure that a masonry chimney meets the minimum standards...

Page 9: ...of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fiberglass insulation from the outer surface of the wall thimble to wall combustibles Sup...

Page 10: ...ions it may rot instead of drying This point cannot be over stressed the vast majority of the problems related to the operation of a wood stove is caused by the fact that the wood used was too damp or...

Page 11: ...wood only Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods as compared to softwoods or to green or freshly cut hardwoods Attempts to use wet or unsea...

Page 12: ...rates after a good fire is established a lower burn rate may be a better option for efficient heating A lower burn rate slows the flow of usable heat out of the home through the chimney and it also co...

Page 13: ...g your fuel the primary air slide should be set at the medium setting which is about 1 2 inch open from the fully closed position For a low burn setting once the high burn or medium fuel load is burne...

Page 14: ...Make sure the blades do not have build up CAUTION Do not overfire appliance You are overfiring if any part of the appliance glows red Close the door and shut damper immediately to reduce the air suppl...

Page 15: ...tended periods While the modern combustion systems in heaters drastically reduce the amount of CO emitted out the chimney exposure to the gases in closed or confined areas can be dangerous Make sure y...

Page 16: ...INSULA TION AND TEMPERATURE RATING 105 C CAUTION MOVING PARTS CAN CAUSE INJURY DO NOT OPERATEWITH COVER REMOVED DANGER SHOCKHAZARD DISCONNECT POWERSOURCEBEFOREINSTALLATION AND WHENEVER SERVICING BLOWE...

Page 17: ...912 Ash Drawer 1 8 26548 Ash Drawer Support 1 9 26541 Left Side Skirt 1 10 40597 Skirt Corner 2 11 26546 Front Skirt 1 12 26553 Right Side Skirt 1 13 69911 Pedestal 1 IN ORDER TO MAINTAIN WARRANTY COM...

Page 18: ...lf Brick Ash Plug 1 7 86698 Tube 1 Secondary Air Tube 4mm 1 8 86699 Tube 2 3 Secondary Air Tube 3mm 2 9 86700 Tube 4 Secondary Air Tube 2 5mm 1 10 86701 Tube 5 Secondary Air Tube 2 0mm 1 11 86702 Tube...

Page 19: ...19 Notes All manuals and user guides at all guides com...

Page 20: ..._______ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _________________________________ Stov...

Page 21: ...ujours le num ro de mod le complet qui se trouve sur la plaque signal tique fix e sur l appareil de chauffage Lors de commandes de pi ces d tach es donnez toujours les informations suivantes telles qu...

Page 22: ..._____ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie ___________________________________ N de t l pho...

Page 23: ...cendre demi brique 1 7 86698 tube d air secondaire 1 4mm 1 8 86699 tube d air secondaire 2 3 3mm 2 9 86700 tube d air secondaire 4 2 5mm 1 10 86701 tube d air secondaire 5 2 0mm 1 11 86702 tube d air...

Page 24: ...niture de foyer 1 7 69912 Tiroir cendres 1 8 26548 Support de tiroir cendres 1 9 26541 Jupe c t gauche 1 10 40597 Coin de jupe 2 11 26546 Jupe avant 1 12 26553 Jupe c t droit 1 13 69911 Pi destal 1 AF...

Page 25: ...ct avec une surface chaude Garder le fil lectrique 12po 30cm au moins de la surface du po le ou des conduits ATTENTION PI ces mobiles pouvant causer des blessures Ne pas faire fonctionner si le cou ve...

Page 26: ...alis disponible dans les magasins o les po les bois sont vendus Le verre ne doit tre lav qu froid ATTENTION LES CENDRES POURRAIENT CONTENIR DES EMBRES CHAUDES M ME APR S DEUX JOURS SANS FAIRE FONCTION...

Page 27: ...uent des r sidus de cr osote s accumulent sur le rev tement du conduit de fum e Lorsqu elle est allum e cette cr osote fait un feu extr mement lev Le raccord de chemin e et la chemin e doivent tre ins...

Page 28: ...t optimal de cet appareil il est recommand de le faire fonctionner avec une charge de bois approximativement quivalente la hauteur des briques r fractaires Il est important de noter que la combustion...

Page 29: ...on suffi sante pour liminer la fum e ou les odeurs caus es par ces feux ATTENTION ne laissez pas l appareil sans surveillance avec la porte ouverte Remarque utilisez uniquement du bois de chauffage s...

Page 30: ...ire ou de b ches avec des additifs chimiques Les b ches fabriqu es partir de sciure de bois compress e 100 peuvent tre br l es mais faites attention br ler trop de ces b ches en m me temps Commencez a...

Page 31: ...ne saurait trop soulign que la vaste majorit des probl mes li s au fonctionnement d un insert bois est caus e par le fait que le bois utilis tait trop humide ou avait s ch dans de mauvaises conditions...

Page 32: ...une partie de chemin e Solid Pak fabriqu e en usine agr e d au moins 12 po 304 mm de diam tre int rieur avec une isolation de 1 po 25 4 mm ou plus et un raccord de chemin e de 8 po de diam tre int ri...

Page 33: ...u homologu Mur combustible Consulter D gagement des combustibles Protecteur de plancher Conduit de raccordement de chemin e Solive de toit combustible Chemin e homologu Mitre Solin CHEMIN E EN MA ONNE...

Page 34: ...ique un tirage excessif Pente de po par pied Partie m le vers le bas 3 vis Vers l appareil Installer l extr mit sertie vers le po le Direction de la circulation des gaz de conduits de fum e CHEMIN E T...

Page 35: ...teur de po le bois certifi Percez un trou de 5 pouces travers le mur au point d entr e souhait Le point d entr e doit tre au niveau ou en dessous du niveau du tuyau d air d admission sur le po le bois...

Page 36: ...dre aux exigences suivantes Le chauffe eau doit tre connect une chemin e pr fabriqu e conforme la norme CAN ULC S629 norme pour les chemin es pr fabriqu es 650 C Le radiateur doit tre fix en permanenc...

Page 37: ...cons quent tre install dans la pi ce o vous passez le plus de temps et dans la pi ce la plus spacieuse possible Rappelez vous que les po les bois produisent une chaleur rayonnante la chaleur que nous...

Page 38: ...ux pi ces d angle A la section centrale B de la plinthe et fixez les avec quatre 4 vis t te bomb e 2 Fixez les plinthes lat rales C et D aux pi ces d angle et fixez les avec quatre 4 vis t te bomb e 3...

Page 39: ...DE D CHETS NI DE FLUIDES INFLAMMABLES TELS QUE L ESSENCE LE NAPTHA OU L HUILE POUR MOTEUR NE CONNECTEZ PAS LE PO LE UN CONDUIT OU CIRCUIT DE DISTRIBUTION D AIR FERMEZ TOUJOURS LA PORTE APR S L ALLUMAG...

Page 40: ...Californie comme causant le cancer et des malformations cong nitales ou autres dommages au f tus Pour obtenir plus de renseignements veuillez consulter le site www P65warnings ca gov Conservez ces ins...

Reviews: