INSTALLATION

6” (152.4 mm) space. There should also be a support 

sized to fit and hold the metal chimney connector. See 

that the supports are fastened securely to wall surfaces 

on all sides. Make sure fasteners used to secure the metal 

chimney connector do not penetrate chimney flue liner.

Method D - 2” (50.8 mm) Clearance to Combustible 

Wall Member: Start with a solid-pak listed factory 

built chimney section at least 12” (304 mm) long, with 

insulation of 1” (25.4 mm) or more, and an inside diameter 

of 8” (2 inches [51 mm] larger than the 6” [152.4 mm] 

chimney connector). Use this as a pass-through for a 

minimum 24-gauge single wall steel chimney connector. 

Keep solid-pak section concentric with and spaced 1” 

(25.4 mm) off the chimney connector by way of sheet 

metal support plates at both ends of chimney section. 

Cover opening with and support chimney section on both 

sides with 24 gauge minimum sheet metal supports. See 

that the supports are fastened securely to wall surfaces 

on all sides. Make sure fasteners used to secure chimney 

flue do not penetrate flue liner.

NOTES: Connectors to a masonry chimney, excepting 

method B, shall extend in one continuous section through 

the wall pass-through system and the chimney wall, to 

but not past the inner flue liner face. A chimney connector 

shall not pass through an attic or roof space, closet or 

similar concealed space, or a floor, or ceiling.

CHIMNEY CONNECTOR

•  Your chimney connector and chimney must have the 

same diameter as the furnace outlet. If this is not the 

case, we recommend you contact your dealer in order 

to ensure there will be no problem with the draft.

•  The furnace pipe must be made of aluminized or cold 

roll steel with a minimum thickness of 0.021” or 0.53 

mm. It is strictly forbidden to use galvanized steel.

•  Your connector should be assembled in such a way that 

the male section (crimped end) of the pipe faces down. 

Attach each of the sections to one another with three 

equidistant metal screws. Seal the joints with furnace 

cement.

•  The pipe must be short and straight. All sections 

installed horizontally must slope at least 1/4 inch 

per foot, with the upper end of the section toward 

the chimney. Any installation with a horizontal run 

of furnace pipe must conform to NFPA 211. You may 

contact NFPA (National Fire Protection Association) 

and request the latest edition of the NFPA Standard 

211.

•  To ensure a good draft, the total length of the furnace 

pipe should never exceed 8’ to 10’ (2.4m to 3.04 m). 

(Except for cases of vertical installation, cathedral-roof 

style where the smoke exhaust system can be much 

longer and connected without problem to the chimney 

at the ceiling of the room).

•  There should never be more than two 90 degrees 

elbows in the smoke exhaust system.

•  Installation of a “barometric draft stabilizer” (fireplace 

register) on a smoke exhaust system is prohibited.

•  Do not use with a flue damper. With a controlled 

combustion coal furnaces the draft is regulated upon 

intake of the combustion air in the furnace and not at 

the exhaust.

3 screws

Flow

Direction

of Flue

Gases

Install 

crimped 

end

towards 

stove.

Male Part Downwards

1/4” slope per foot

Summary of Contents for HOTBLAST 1500

Page 1: ...act local building or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you...

Page 2: ...LEL INSTALLATION WITH EXISTING FORCED AIR GAS OR OIL FIRED FURNACE U S ONLY FOR INSTALLATION AS A CENTRAL FURNACE CAUTIONS HOT WHILE IN OPERATION KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY...

Page 3: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Page 4: ...WHEN ADDING FRESH COAL DANGER RISK OF FIRE OR EXPLOSION DO NOT BURN GARBAGE GASOLINE DRAIN OIL OR OTHER FLAMMABLE LIQUIDS WARNING FIRE HAZARD DO NOT OPERATE WITH FIRE DRAFT EXCEEDING 0 06 W C DO NOT...

Page 5: ...until some pressure is required to lock feed door during firing sequence 5 Install the thermodisc on rear of furnace cabinet with the two screws provided Mount the conduit assembly from the junction b...

Page 6: ...k will attach to It uses a standard 16 x 20 x 1 filter NOT INCLUDED to reduce the amount of dust particles from being transferred thru you duct work system DR 6 BAROMETRIC DAMPER REGULATOR In the unli...

Page 7: ...he central system also comes on The blower will only come on when the temperature in the plenum has reached the setting on the blower control This is to ensure that there is sufficient warm air in the...

Page 8: ...factors Too much draft may cause excessive temperatures in the appliance Inadequate draft may cause backpuffing into the room and plugging of the chimney Inadequate draft will cause the appliance to...

Page 9: ...or cement the clay liner in place to the chimney flue liner Method B 9 228 6 mm Clearance to Combustible Wall Member Using a 6 152 4 mm inside diameter listed factory built Solid Pak chimney section...

Page 10: ...have the same diameter as the furnace outlet If this is not the case we recommend you contact your dealer in order to ensure there will be no problem with the draft The furnace pipe must be made of a...

Page 11: ...stated on the label on the fuel door c Clearance from combustible materials must comply with those stated on the label on the side of the unit Refer to the clearance table in the front of this manual...

Page 12: ...12 2021 United States Stove Company CENTRAL INSTALLATION ADD ON INSTALLATION INSTALLATION METHODS OF INSTALLATION...

Page 13: ...ON B PLENUM COLLECTOR BOX TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE SOLID FUEL FURNACE FILTER BOX COLD AIR RETURN INSTALLATION C PLENUM TOP OPTIONAL TO EXISTING DUCT WORK WARM AIR EXISTING FURNA...

Page 14: ...LATION F FURNACE PLENUM EXISTING FURNACE SOLID FUEL FURNACE COLD AIR RETURN 2 min CLEARANCE INSTALLATION G SOLID FUEL FURNACE 2 min CLEARANCE COLD AIR RETURN TO FILTER BOX INSTALLATION H SOLID FUEL FU...

Page 15: ...heater ineffective and cause smoke POWER FAILURE After loss of power remove the filter if provided and do not expect to keep home at normal temperatures ADJUSTING THE BAROMETRIC DRAFT REGULATOR 1 Dril...

Page 16: ...be used to ventilate the cellar or basement If there is a cleanout opening at the base of the chimney it must be closed tightly 4 If the chimney is operating too cool water will condense in the chimn...

Page 17: ...and rough handling or abuse When installing your furnace use care in handling Clean with soap and warm water when furnace in not hot DO NOT use any acids or scouring soap as these wear and dull the fi...

Page 18: ...15 seconds and open door SLOWLY then refuel Check length of flue pipe to chimney Your unit should be within six 6 feet of your chimney Make sure chimney cap is not too close to the top of the chimney...

Page 19: ...e Burning in this fashion allows heat to drive off the volatile gases and turbulence created increases the burn efficiency There will have to be some experimenting with the individual setup as no two...

Page 20: ...ere the house does not become too cold It is important that you begin banking early enough before retiring or leaving that you can make necessary adjustments after the fire is well established To revi...

Page 21: ...2021 United States Stove Company 21 REPAIR PARTS 22 6 8 7 9 20 18 19 17 16 14 10 15 11 12 13 21 1 5 2 3 4 1 28 27 26 29 30 31 24 25 32 33 23 41 39 37 38 40 34...

Page 22: ...Kep Nut 2 21 68228 Ash Pan 1 22 23398 Flue Baffle 2 23 22761B Flue Collar Ring 1 24 22762B Forced Draft Ring 1 25 86402 1 1 2 Pipe Plug 1 26 80230 Blower 2 27 89319 Gasket Blower 2 28 83340 1 4 20 Cl...

Page 23: ...75 Thermostat Knob 1 10 23425 Handle Bracket 2 11 89520 Wooden Handle 1 12 86318 Thermostat Chain 1 2 ft 13 68217 Feed Door Assembly Includes Door and Gasket 1 N S 83106S Machine Screw 10 24 x 1 2 SL...

Page 24: ..._____ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ________________________...

Reviews: