© 2021 United States Stove Company

SAFETY

ATTENTION:

•  FAILURE TO FOLLOW THE INFORMATION IN 

THIS MANUAL WILL CAUSE A HAZARD THAT 

COULD RESULT IN DEATH, SERIOUS BODILY 

INJURY, AND/OR PROPERTY DAMAGE.

•  CHECK YOUR LOCAL CODES. THE INSTALLATION 

MUST COMPLY WITH THEIR RULINGS.

•  ALWAYS CONNECT THIS FURNACE TO A 

CHIMNEY AND VENT TO THE OUTSIDE. NEVER 

VENT TO ANOTHER ROOM OR INSIDE A 

BUILDING.

•  DO NOT CONNECT THIS FURNACE TO AN 

ALUMINUM TYPE B GAS VENT. THIS IS NOT 

SAFE AND IS PROHIBITED BY THE NATIONAL 

FIRE PROTECTION ASSOCIATION CODE. THIS 

FURNACE REQUIRES A MASONRY OR LISTED 

FACTORY BUILT CHIMNEY FOR RESIDENTIAL 

TYPE OR BUILDING HEATING APPLIANCE 

CHIMNEY. USE A 6" DIAMETER CHIMNEY OR 

LARGER, THAT IS HIGH ENOUGH TO GIVE A 

GOOD DRAFT.

•  INSPECT CHIMNEY CONNECTOR AND 

CHIMNEY BEFORE AND FREQUENTLY DURING 

THE HEATING SEASON FOR ANY DEPOSIT 

OF CREOSOTE OR SOOT WHICH MUST BE 

REMOVED.

•  PROVIDE AIR FOR COMBUSTION INTO THE 

ROOM WHERE THE FURNACE IS LOCATED. IF 

THE INTAKE IS NOT IN THE SAME ROOM, AIR 

MUST HAVE FREE ACCESS TO THE ROOM.

•  CAST IRON PARTS MUST BE "SEASONED" TO 

AVOID CRACKING, BUILD ONLY SMALL FIRES 

ON FIRST USE.

•  TO PREVENT INJURY, DO NOT ALLOW ANYONE 

TO USE THIS FURNACE WHO IS UNFAMILIAR 

WITH THE CORRECT OPERATION OF THE 

FURNACE.

CAUTION

GASES THAT ARE DRIVEN FROM FRESH COAL 

MUST BE BURNED OR THEY WILL ACCUMULATE 

AND EXPLODE. NEVER SMOTHER A FIRE WHEN 

ADDING FRESH COAL.

DANGER: RISK OF FIRE OR EXPLOSION.

DO NOT BURN GARBAGE, GASOLINE, DRAIN OIL, 

OR OTHER FLAMMABLE LIQUIDS.

WARNING: FIRE HAZARD.

•  DO NOT OPERATE WITH FIRE DRAFT 

EXCEEDING 0.06" W.C.

•  DO NOT STORE FUELS, PAINTS, THINNERS, 

FLAMMABLE LIQUIDS, OR OTHER HIGHLY 

VOLATILE SUBSTANCES IN THE FURNACE 

ROOM.

CAUTION!

CLEANOUT OF THE HEAT EXCHANGER, FLUE 

PIPE, CHIMNEY, AND DRAFT INDUCER (IF USED), 

IS ESPECIALLY IMPORTANT AT THE END OF THE 

HEATING SEASON TO MINIMIZE CORROSION 

DURING THE SUMMER MONTHS, CAUSED BY 

ACCUMULATED ASH.

CAUTION!

INSPECT FLUE PIPES, FLUE PIPE JOINTS AND 

FLUE PIPE SEALS REGULARLY TO ENSURE THAT 

SMOKE AND FLUE GASES ARE NOT DRAWN INTO, 

AND CIRCULATED BY, THE AIR CIRCULATION 

SYSTEM.

SAFETY NOTICE:

IF THIS HEATER IS NOT PROPERLY INSTALLED, 

A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, 

FOLLOW THE INSTALLATION DIRECTIONS. 

CONTACT LOCAL BUILDING OR FIRE OFFICIALS 

ABOUT RESTRICTIONS AND INSTALLATION 

INSPECTION REQUIREMENTS IN YOUR AREA. 

IF NOT ALREADY INSTALLED, WE RECOMMEND 

THAT SMOKE DETECTORS BE INSTALLED.

CAUTION:

HOT SURFACES! KEEP CHILDREN AWAY. DO NOT 

TOUCH DURING OPERATION.

CREOSOTE ACCUMULATION CAUSES CHIMNEY 

FIRES. YOU SHOULD CHECK (OR HAVE CHECKED BY 

A QUALIFIED CHIMNEY SWEEP) YOUR CHIMNEY FOR 

CREOSOTE DEPOSITS AT LEAST MONTHLY DURING 

THE HEATING SEASON. ANY ACCUMULATIONS 

SHOULD BE REMOVED. COMPLETE CHIMNEY 

INSPECTIONS AND CLEANING SHOULD BE 

CONDUCTED ANNUALLY; TYPICALLY, THIS TASK 

SHOULD BE PERFORMED PRIOR TO EACH HEATING 

SEASON. IF USING AN EXISTING CHIMNEY, IT MUST 

BE INSPECTED PRIOR TO THE INSTALLATION OF 

YOUR NEW WOOD STOVE.

Summary of Contents for HOTBLAST 1500

Page 1: ...act local building or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you...

Page 2: ...LEL INSTALLATION WITH EXISTING FORCED AIR GAS OR OIL FIRED FURNACE U S ONLY FOR INSTALLATION AS A CENTRAL FURNACE CAUTIONS HOT WHILE IN OPERATION KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY...

Page 3: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Page 4: ...WHEN ADDING FRESH COAL DANGER RISK OF FIRE OR EXPLOSION DO NOT BURN GARBAGE GASOLINE DRAIN OIL OR OTHER FLAMMABLE LIQUIDS WARNING FIRE HAZARD DO NOT OPERATE WITH FIRE DRAFT EXCEEDING 0 06 W C DO NOT...

Page 5: ...until some pressure is required to lock feed door during firing sequence 5 Install the thermodisc on rear of furnace cabinet with the two screws provided Mount the conduit assembly from the junction b...

Page 6: ...k will attach to It uses a standard 16 x 20 x 1 filter NOT INCLUDED to reduce the amount of dust particles from being transferred thru you duct work system DR 6 BAROMETRIC DAMPER REGULATOR In the unli...

Page 7: ...he central system also comes on The blower will only come on when the temperature in the plenum has reached the setting on the blower control This is to ensure that there is sufficient warm air in the...

Page 8: ...factors Too much draft may cause excessive temperatures in the appliance Inadequate draft may cause backpuffing into the room and plugging of the chimney Inadequate draft will cause the appliance to...

Page 9: ...or cement the clay liner in place to the chimney flue liner Method B 9 228 6 mm Clearance to Combustible Wall Member Using a 6 152 4 mm inside diameter listed factory built Solid Pak chimney section...

Page 10: ...have the same diameter as the furnace outlet If this is not the case we recommend you contact your dealer in order to ensure there will be no problem with the draft The furnace pipe must be made of a...

Page 11: ...stated on the label on the fuel door c Clearance from combustible materials must comply with those stated on the label on the side of the unit Refer to the clearance table in the front of this manual...

Page 12: ...12 2021 United States Stove Company CENTRAL INSTALLATION ADD ON INSTALLATION INSTALLATION METHODS OF INSTALLATION...

Page 13: ...ON B PLENUM COLLECTOR BOX TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE SOLID FUEL FURNACE FILTER BOX COLD AIR RETURN INSTALLATION C PLENUM TOP OPTIONAL TO EXISTING DUCT WORK WARM AIR EXISTING FURNA...

Page 14: ...LATION F FURNACE PLENUM EXISTING FURNACE SOLID FUEL FURNACE COLD AIR RETURN 2 min CLEARANCE INSTALLATION G SOLID FUEL FURNACE 2 min CLEARANCE COLD AIR RETURN TO FILTER BOX INSTALLATION H SOLID FUEL FU...

Page 15: ...heater ineffective and cause smoke POWER FAILURE After loss of power remove the filter if provided and do not expect to keep home at normal temperatures ADJUSTING THE BAROMETRIC DRAFT REGULATOR 1 Dril...

Page 16: ...be used to ventilate the cellar or basement If there is a cleanout opening at the base of the chimney it must be closed tightly 4 If the chimney is operating too cool water will condense in the chimn...

Page 17: ...and rough handling or abuse When installing your furnace use care in handling Clean with soap and warm water when furnace in not hot DO NOT use any acids or scouring soap as these wear and dull the fi...

Page 18: ...15 seconds and open door SLOWLY then refuel Check length of flue pipe to chimney Your unit should be within six 6 feet of your chimney Make sure chimney cap is not too close to the top of the chimney...

Page 19: ...e Burning in this fashion allows heat to drive off the volatile gases and turbulence created increases the burn efficiency There will have to be some experimenting with the individual setup as no two...

Page 20: ...ere the house does not become too cold It is important that you begin banking early enough before retiring or leaving that you can make necessary adjustments after the fire is well established To revi...

Page 21: ...2021 United States Stove Company 21 REPAIR PARTS 22 6 8 7 9 20 18 19 17 16 14 10 15 11 12 13 21 1 5 2 3 4 1 28 27 26 29 30 31 24 25 32 33 23 41 39 37 38 40 34...

Page 22: ...Kep Nut 2 21 68228 Ash Pan 1 22 23398 Flue Baffle 2 23 22761B Flue Collar Ring 1 24 22762B Forced Draft Ring 1 25 86402 1 1 2 Pipe Plug 1 26 80230 Blower 2 27 89319 Gasket Blower 2 28 83340 1 4 20 Cl...

Page 23: ...75 Thermostat Knob 1 10 23425 Handle Bracket 2 11 89520 Wooden Handle 1 12 86318 Thermostat Chain 1 2 ft 13 68217 Feed Door Assembly Includes Door and Gasket 1 N S 83106S Machine Screw 10 24 x 1 2 SL...

Page 24: ..._____ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ________________________...

Reviews: