INSTALLATION
on a non-combustible floor surface in compliance with
clearance requirements for an alcove installation.
IMPROPER INSTALLATION
The use of other components other than stated herein
could cause bodily harm, heater damage, and void your
warranty. The manufacturer will not be held responsible
for damage caused by the malfunction of a stove due to
improper venting or installation.
FLOOR PROTECTION
This unit must be installed on a non-combustible floor
surface. If a floor pad is used, it should be certified or
equal. The floor pad or non-combustible surface should
be large enough to extend a minimum of 6” (153 mm) in
front, 6” (153 mm) on each side, and 1” (26 mm) behind
the stove. Floor protection must extend under and 2”
(51 mm) to each side of the chimney tee for an interior
vertical installation. A Floor Protector of 1” (26 mm) thick
is recommended for this installation.
D
B
C
B
A
A
Rear (through wall)
1”
25 mm
B
Side
6” 152 mm
C
Front
6” 152 mm
D Rear (interior vertical) 2”
50 mm
CLEARANCES
Your pellet stove has been tested and listed for installation
in residential, mobile home, and alcove applications in
accordance with the clearances given in this manual.
NOTE: The distance on the side of your pellet stove may
need to be greater than the minimum required clearance
for suitable access to the control panel. For safety
reasons, please adhere to the installation clearances and
restrictions. Any reduction in clearance to combustibles
may only be done by means approved by a regulatory
authority.
F
G
E
H
F
G
J
J
J
J
K
PARALLEL
E Backwall to unit
9.5” 241 mm
F Sidewall to flue
14” 330 mm
G Sidewall to top edge
of unit
8” 203 mm
H Backwall to flue
3”
76.2mm
CORNER J Adjacent wall to unit 8” 203 mm
ALCOVE
K Alcove depth
36” 914 mm