INSTALLATION
4. The house is equipped with a well-sealed vapor
barrier and tight fitting windows and/or has any
powered devices that exhaust house air.
5. There is excessive condensation on windows in the
winter.
6. A ventilation system is installed in the house.
Slide the hose clamp over the aluminium flex pipe.
Then slide the flex pipe over the air intake tube of the
stove. Next tighten the hose clamp over the end of the
aluminium flex hose.
FOR USE IN MOBILE HOMES
• WARNING! DO NOT INSTALL IN SLEEPING
ROOM.
• CAUTION! THE STRUCTURAL INTEGRITY
OF THE MOBILE HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.
• INSTALL IN ACCORDANCE WITH 24 CFR, PART
3280 (HUD).
• USE A FACTORY BUILT CHIMNEY THAT
COMPLIES WITH UL 103 STANDARDS;
THEREFORE IT MUST BE A TYPE HT (2100°F).
• USE A SPARK ARRESTER.
• THE STOVE MUST BE ATTACHED TO THE
STRUCTURE OF THE MOBILE HOME.
SECURING APPLIANCE’S ON A PEDESTAL
TO THE FLOOR
Use the designated holes to secure the unit to the floor.
SECURING APPLIANCE’S WITH LEGS TO
THE FLOOR
1. The bracket engages around the square extrusion of
the leveling bolt inserted into the leg.
2. Once appliance is leveled, position the bracket and
attach to the floor using the appropriate hardware
needed for your specific flooring.
3. Install one bracket per leg or consult your local
authority having jurisdiction to determine how many
points of attachment are required.
In addition to the previously detailed installation
requirements, mobile home installations must meet the
following requirements:
• The space heater is to be connected to a factory-built
chimney conforming to CAN/ULC-S629, Standard for
650°C Factory-Built Chimneys.
• The heater must be permanently attached to the floor.
There are two holes in the pedestal base, use 3/8” bolts
through the floor.
• The heater must be electrically grounded to the steel
chassis of the mobile home with 8 GA copper wire
using a serrated or star washer to penetrate paint or
protective coating to ensure grounding.
• When moving your mobile home, all exterior venting
must be removed while the mobile home is being
relocated. After relocation, all venting must be
reinstalled and securely fastened.
• Outside Air is mandatory for mobile home installation.
See your dealer for purchasing.
• Check with your local building officials as other codes
may apply.
• Only use the specified components listed in this manual
for this unit. The use of components that are not meant
for this unit can cause unsafe conditions.
CHIMNEY CONNECTOR (STOVE PIPE)
The chimney connector and chimney must have the same
diameter as the stove outlet (6”). If this is not the case,
we recommend you contact your dealer to ensure there