6

© 2021 U

nited S

tat

es Sto

ve C

ompany

DÉGA

GEMENTS A

UX C

OMBU

STIBLE

S

AVER

TISSEMENT

: RISQ

UE D'INCENDIE

RESPE

CTEZ LE

S DÉ

GAGEMENT

S MINIMAUX 

AUX 

COMB

USTIBLE

S INDIQUÉ

S DANS CE MANUEL ET 

SUR LE

S ÉTIQUET

TES FIXÉE

S À L'APPAREIL

. NE 

PAS S

TOCKER DE B

OIS, TO

UT TYPE DE VAPEUR

S OU 

DE LIQUIDE

S INFLAMMABLE

S, PLA

CER MEUBLES, 

TAPIS, T

APIS, VÊTEMENTS O

U AUTRE

S OBJET

COMB

USTIBLE

S DANS L

A ZONE DE DÉ

GAGEMENT

.

LINTEAU

MUR LA

TERAL

LINTEAU

MUR LA

TERAL

Dimensions d’ouv

ertur

e du foy

er

po

mm

A

Haut

eur Minimum

29

737

B

Lar

geur Minimum

23

585

C

Pro

fondeur Minimum

14

356

Déga

gemen

ts des ma

téria

ux inflammables

D

Min. Distanc

e à la paroi la

tér

ale

9

229

E

Min. Distanc

e à la partie s

upérieure

14

356

F

Min. Distanc

e jusqu’

au man

tea

u

19

483

G

Min. Distanc

e à la garnit

ure la

tér

ale

9

229

H

Min. Pro

tec

teur de plancher a

van

t

17

432

I

Min. Côt

é prot

ecteur de 

plancher

USA

6

153 

CAN

8

204

AIR DE COMB

USTION EX

TÉRIEUR

ATTENTION:

BRANCHEZ T

OU

JO

URS CET APP

AREIL À UNE CHEMINÉE 

ÉVENTÉE À L'EXTÉRIEUR

. NE JAMAIS VENTILER D

ANS 

UNE AUTRE PIÈ

CE, UN ESP

ACE DE CHENILLE

S, UN 

GRENIER OU À L'INTÉRIEUR D'UN B

ÂTIMENT

. NE PAS 

RA

CCORDER CET APP

AREIL À UN FUMÉ DE CHEMINÉE 

SERVANT UN A

UTRE APPAREIL

Votr

e appareil lui-même ne cr

ée pas de c

ouran

t d’air

. Le tir

age 

est a

ssur

é par la cheminée

. Pour aider 

à fournir 

le tirag

e requis, 

un kit d’air fr

ais (4F

AK) es

t disponible à l’acha

t aupr

ès de votr

rev

endeur de poêles local. L

orsqu’

il est ins

tallé c

orrec

temen

t, 

le kit 4FAK es

t conç

u pour fournir le tir

age néc

essair

e au bon 

fonc

tionnement. P

our obtenir un tir

age adéqua

t, v

otr

e cheminée 

doit répondr

e aux tr

ois exig

ences de ha

uteur minimale dé

taillées 

dans la figur

e 8. U

n tirag

e minimum de 0,0

5 w.c. (mes

uré dans 

la colonne 

d’ea

u) es

t néc

essair

e pour 

un tir

age 

corr

ect 

afin 

d’évit

er les souffla

ges de do

s, les déver

semen

ts de f

umée et 

pour maximis

er les performanc

es. Des jaug

es pour mesur

er le 

tirag

e son

t facilemen

t disponibles dans les maga

sins de poêles 

et s

ont éc

onomiques à louer ou à acheter

. Des fac

teur

s tels 

que le ven

t, la pr

ession bar

ométrique

, les arbres, le t

errain e

t la 

tempér

atur

e de la cheminée peuven

t avoir un e

ffet né

gatif s

ur le 

tirag

e. L

e fabric

ant ne peut ê

tre t

enu respons

able des fac

teur

ext

ernes conduis

ant à une r

édaction moins qu’

optimale

. Si 

vous a

vez un pr

oblème avec un tir

age ins

uffisan

t, v

ous deve

con

tac

ter un en

trepr

eneur en chauff

age e

t en refr

oidissemen

agr

éé pour obtenir de l’

aide pour rés

oudre le pr

oblème.

LA C

ONDITION DE LA CHEMINÉE ET LE

CONDITIONS DE DÉ

GAGEMENT NUL

Une cheminée de maç

onnerie doit respec

ter des normes 

minimales, la norme NFPA 211, ou l’

équivalen

t pour une 

installa

tion sûr

e. C

ontac

tez un pr

ofes

sionnel, un installa

teur 

accr

édité, l’

inspecteur des a

utorit

és locales ou les pompier

pour plus d’in

forma

tions sur les c

onditions d’ins

talla

tion. 

Votr

e compa

gnie d’

ass

uranc

es de

vrait 

pouvoir 

rec

ommander 

un inspec

teur 

qualifié. 

Les 

inspections 

doiven

t couvrir 

les 

vérific

ations s

uivan

tes: 

1. 

La c

ondition de la cheminée et du c

onduit de cheminée. L

cheminée de maçonnerie e

t le conduit de cheminée doiv

ent 

êtr

e inspectés a

van

t l’ins

talla

tion de cet appar

eil. Ils ne 

doiven

t pas pr

ésen

ter de fis

sur

es, de mortier de ma

uvais

qualité, de dépô

ts de cr

éoso

te, d’

obstr

uction ou t

out autr

preuv

e de détérior

ation. 

N’impor

te lequel de c

es problèmes 

devr

a êtr

e répar

é avan

t l’ins

talla

tion. N’ENLEVEZ P

AS LE

BRIQUE

S ou LE MORTIER de la cheminée e

xistan

te lor

s de 

l’ins

talla

tion de cet appar

eil.

2. 

Taille 

du conduit 

de cheminée

. Le 

diamètr

e minimum 

du 

conduit de cheminée es

t 152 mm. Main

tene

z une haut

eur 

minimum de conduit de cheminée (mes

urée du des

sus de 

l’appar

eil au s

ommet de la cheminée

) de 4,5 m. L

es conduit

doiven

t dépass

er le toit par a

u moins 0,9 m e

t au moins 0

,6 

INSTALL

ATION

Summary of Contents for US1800E

Page 1: ...ions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow inst...

Page 2: ...operation at high burn rate burning cordwood 27 1 8 691 mm 26 1 2 673 mm 13 1 4 337 mm 6 1 155 mm 21 3 4 553 mm 22 3 8 568 mm 15 1 2 394 mm 4 11 16 119 mm CAUTIONS HOT WHILE IN OPERATION KEEP CHILDRE...

Page 3: ..._________________________________________ If no Date of inspection of the existing chimney system ___________________________________________________________ COMMISSIONING Confirm Hearth Pad Installat...

Page 4: ...the top of the appliance The surround assembly is held in place with two springs at the top of either corner of the appliance SPRING SURROUND Slots in surround slide of firebox top Figure 6 Surround I...

Page 5: ...IED INSTALLER TO ENSURE A CORRECT AND SAFE INSTALLATION NEVER USE TEMPORARY OR MAKESHIFT COMPROMISES DURING THE INSTALLATION WARNING PROVIDE ADEQUATE COMBUSTION AIR TO THE ROOM WHERE THE APPLIANCE IS...

Page 6: ...ion of this manual A minimum draft of 0 05 w c measured in water column is required forproperdraftingtopreventbackpuffing smokespillage and to maximize performance Gauges to measure draft are readily...

Page 7: ...is a building code requirement Inadequate air supply will cause poor combustion inefficient operation creosote buildup back drafting and smoke puffing into the living areas If any of the following con...

Page 8: ...plate to a visible location in the fireplace After choosing a visible location in the fireplace permanently attach the warning plate by screwing or nailing it into place Note Use the holes in the labe...

Page 9: ...he chimney must meet all minimum height requirements 4 Never use a chimney to ventilate a cellar or basement Contact your local building authority for approved methods of installation and any necessar...

Page 10: ...HAZARDS FROM HIGH SURFACE TEMPERATURES NEVER LEAVE SMALL CHILDREN UNSUPERVISED WHEN THEYAREINTHESAMEROOMASTHEAPPLIANCE DURING OPERATION TO PREVENT BURNS ALWAYS WEAR PROTECTIVE CLOTHING LEATHER HEARTH...

Page 11: ...itions These problems can be ignition problems creosote build up causing chimney fires low energy yield blackened windows incomplete log combustion Do not burn manufactured logs made of wax impregnate...

Page 12: ...inutes each The third fire should be at a temperature of approximately 500 F for 20 minutes Provide adequate cross ventilation to clear any smoke or odor caused by initial firings Notice Use solid woo...

Page 13: ...can be an effective method of determining how efficiently the combustion process is taking place in the given settings Visible smoke consists of unburned fuel and moisture leaving your stove Learn to...

Page 14: ...dry wood This allows clean burns and higher chimney temperatures therefore less creosote deposit Leave the air control fully open for about 5 min every time you reload the stove to bring it back to p...

Page 15: ...it When replacing the glass you should change the glass gasket to make sure you keep it sealed Never wash the glass with a product that may scratch Use a specialized product available in the stores w...

Page 16: ...to your unit When ordering replacement parts the information in this manual will help to ensure the correct items are ordered Before contacting customer service write down the model number and the se...

Page 17: ...13 83913 Extension Spring 2 14 26269 Top Surround 1 15 26270 Side Surround 2 16 891992 1 Surround Trim R 1 17 891992 2 Surround Trim L 1 18 891992 3 Surround Top Trim L 1 19 891992 4 Surround Top Trim...

Page 18: ...1 5 891989 1 Firebrick 3 33 x 9 8 6 86963 Secondary Tube 3 7 88158 Ceramic Fiber Board Front 1 8 88159 Ceramic Fiber Board Rear 1 9 88160 Blanket Insulation 1 3 2 5 4 1 6 8 9 7 REPAIR PARTS To order...

Page 19: ...______ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No _______________________...

Page 20: ...20 2021 United States Stove Company NOTES...

Page 21: ...ce de 07 Date ______________________ Nom de l ing nieur _________________________________ N de licence ______________________________________ Compagnie ________________________________________ N de t...

Page 22: ...3 33 x 9 8 6 86963 Tube secondaire 3 7 88158 Panneau en fibre de c ramique avant 1 8 88159 Panneau en fibre de c ramique arri re 1 9 88160 Isolation de couverture 1 3 2 5 4 1 6 8 9 7 Pour commander d...

Page 23: ...1 5 893261 Glissi re d amortisseur 1 6 29301 Accolade coulissante 2 7 893261 Manche en bois 1 8 29300 Couverture 1 9 29298 Amortisseur 1 10 611007 Cabinet gauche 1 11 892294 Axe De Charni re 2 12 4057...

Page 24: ...informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant de contacter le service client notez le num ro de mod le et le num ro de s rie de cet appare...

Page 25: ...remplacez la pi ce endommag e par une nouvelle Effectuez la proc dure l envers apr s l avoir remplac Lors du remplacement de la vitre vous devez changer le joint en verre pour vous assurer de le garde...

Page 26: ...TE Br lez toujours du bois sec Cela permet des br lures propres et des temp ratures de chemin e plus lev es donc moins de d p t de cr osote Laissez le contr le d air compl tement ouvert pendant enviro...

Page 27: ...frir un m lange pr cis d air secondaire et assurer une plus grande efficacit Tout dommage ou d t rioration de ces conduits peuvent r duire l efficacit de la combustion Les conduits d air sont maintenu...

Page 28: ...charbon tabli chargez l unit avec 14 15 lb de bois de corde et fermez imm diatement la porte Laissez la commande d air compl tement ouverte en position HI pendant 15 minutes Apr s 15 minutes tournez l...

Page 29: ...IMINER LA FUM E ET L ODEUR SI L APPAREIL EST SURCHAUFF LA PEINTURE SE D COLORE LORS DE L INSTALLATION DE VOTRE APPAREIL PRENEZ SOIN DE LA MANIPULATION NETTOYER AVEC DU SAVON ET DE L EAU LORSQUE L APPA...

Page 30: ...tre po le bois Le bois doit avoir s ch pendant 9 15 mois de sorte que la teneur en humidit en poids soit r duite en dessous de 20 du poids de la b che Il est tr s important de garder l esprit que m me...

Page 31: ...MAISON NE CONSERVEZ PAS LE BOIS SUR UN PROTECTEUR DE PLANCHER SOUS LES TUYAUX DE PO LE OU N IMPORTE O DANS LES D GAGEMENTS DES SURFACES COMBUSTIBLES SP CIFI ES POUR CET APPAREIL NE JAMAIS FAIRE FONCT...

Page 32: ...our ventiler une cave ou un sous sol Contactez les autorit s locales pour d finir les m thodes approuv es d installation et d terminer la n cessit d obtenir un permis et ou de r aliser une inspection...

Page 33: ...ble dans le foyer Apr s avoir choisi un emplacement visible dans le foyer fixez d finitivement la plaque d avertissement en la vissant ou en la clouant Remarque Utilisez les trous de l tiquette pour m...

Page 34: ...ote un refoulement d air et de fum e dans les pi ces vivre Si n importe laquelle des conditions suivantes est incontestablement pr sente une alimentation d air doit tre install e a L appareil actuel d...

Page 35: ...les d versements de fum e et pour maximiser les performances Des jauges pour mesurer le tirage sont facilement disponibles dans les magasins de po les et sont conomiques louer ou acheter Des facteurs...

Page 36: ...NE CHEMIN E D APPAREIL DE CHAUFFAGE DE B TIMENT HOMOLOGU E UL 103 HT U UTILISEZ UNE CHEMIN E DE 6 DE DIAM TRE ASSEZ LEV E POUR CR ER UN TIRAGE SUFFISANT ATTENTION FOURNISSEZ DE L AIR DE COMBUSTION AD...

Page 37: ...il SPRING SURROUND Slots in surround slide of firebox top Figure 6 Surround Installation Installation de l habillage RESSORT HABILLAGE Entailles dans l habillage glissent sur le dessus de l insert 6 L...

Page 38: ...ion du syst me de chemin e existant ____________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux instructions d inst...

Page 39: ...8 cm 27 1 8 691 mm 26 1 2 673 mm 13 1 4 337 mm 6 1 155 mm 21 3 4 553 mm 22 3 8 568 mm 15 1 2 394 mm 4 11 16 119 mm AVERTISSEMENTS CHAUD DURANT LE FONCTIONNEMENT MAINTENEZ LES ENFANTS LES V TEMENTS ET...

Page 40: ...gion NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l int gralit de ce manuel avant d installer ou d utiliser votre nouveau radiateur Le non respect des instructions peut...

Reviews: