background image

-8-

This appliance must be connected to a listed Stainless Steel Liner, that meets UL1777, which extends from the 

collar to the chimney cap according to the specifications listed on the previous pages. Take into account the 

chimney’s location to ensure it is not too close to neighbors or in a valley which may cause unhealthy or nuisance 

conditions.

IMPORTANCE OF PROPER DRAFT

Draft  is  the  force  which  moves  air  from  the  appliance  up  through  the  chimney.  The  amount  of  draft  in  your 

chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. Too 

much draft may cause excessive temperatures in the appliance. Inadequate draft may cause backpuffing into 

the room and “plugging” of the chimney. Inadequate draft will cause the appliance to leak smoke into the room 

through appliance and chimney connector joints. An uncontrollable burn or excessive temperature indicates 

excessive draft.

Chimneys perform two functions:

1. 

As a means of exhausting smoke and flue gases which are the result of fuel combustion.

2. 

The chimney provides “draft,” which allows oxygen to be continuously introduced into the appliance, so that 

proper combustion is possible. This stove relies on natural draft to operate.

NOTICE: Always provide a source of fresh air into the room where the stove is located. Failure to do so may result 

in air starvation of other fuel burning appliances and the possible development of hazardous conditions, fire, or 

death.

Your appliance itself does not create draft. Draft is provided by the chimney. To help provide the required draft 

there is a fresh air kit (4FAK) available for purchase from your local stove dealer. When installed properly the 4FAK 

kit is designed to provide the draft needed for proper operation. To achieve proper draft your chimney must meet 

the three minimum height requirements detailed in figure 8. A minimum draft of 0.05 w.c. (measured in water 

column) is required for proper drafting to prevent back puffing, smoke spillage, and to maximize performance. 

Gauges to measure draft are readily available at stove stores and are economical to rent or purchase. Factors 

such as wind, barometric pressure, trees, terrain and chimney temperature can have an adverse effect on the 

draft. The manufacturer cannot be held responsible for external factors leading to less than optimal drafting. 

Should you have a problem with inadequate draft, you should contact a licensed heating and cooling contractor 

for assistance in solving the problem.

IMPORTANT INSTALLATION POINTS

1. 

Size chimney flue to appliance collar. This stove requires a minimum 6” diameter flue.

2. 

Never connect this unit to a chimney serving another appliance.

3. 

The chimney must meet all minimum height requirements.

4. 

Never use a chimney to ventilate a cellar or basement.

Contact your local building authority for approved methods of installation and any necessary permits and/or 

inspections.

MASONRY CHIMNEY

Before using an existing masonry chimney, 

clean  the  chimney,  inspect  the  flue  liner, 

and make any repairs needed to be sure 

it is safe to use. As mentioned previously, 

this appliance requires a continuous 

stainless  steel  liner  from  the  appliance 

collar  to  the  chimney  cap.  Make  repairs 

before attaching the stove. The connector 

stove  pipe  and  fittings  you  will  need  to 

connect  directly  to  a  masonry  chimney 

are detailed in the installation instructions. 

If the fireplace chimney must go through a 

combustible wall before entering the main 

chimney, consult a qualified mason or chimney dealer regarding proper materials that meet all local building 

and fire authority codes. The installation must conform to local building and fire codes and latest edition of NFPA 

211. If there is a cleanout opening in the base of the chimney, close it tightly.

Chimney Specifications

Summary of Contents for US1800E

Page 1: ...s This manual will help you to obtain efficient dependable service from the heater and enable you to order repair parts correctly Keep in a safe place for future reference U S Environmental Protection...

Page 2: ...UL 103 HT U S Listed Residential Type and Building Heating Appliance Chimney Use a 6 diameter chimney that is high enough to create sufficient draft 11 Be sure your chimney is safely constructed and i...

Page 3: ...ning Systems for Existing Masonry or Factory Built Chimneys and Vents or CAN ULC S640 Standard for Lining Systems for New Masonry Chimneys 24 Permanently seal any opening between the masonry of the fi...

Page 4: ...acement if the appliance is ever removed The removal of any parts that render the fireplace unusable for burning solid fuel requires a permanent label to be affixed by the installer that states the fi...

Page 5: ...ng fuel fired equipment shows evidence of back puffing smoke roll out inefficient operation or excessive smell in the living area b Opening a window or door alleviates any of the above problems or sym...

Page 6: ...e with a metal warning label Permanently attach the warning plate to a visible location in the fireplace After choosing a visible location in the fireplace permanently attach the warning plate by scre...

Page 7: ...f your stove and radiates heat more evenly If firebricks were removed to position appliance replace them before firing appliance See figure 7 for proper orientation and positioning Install the back ro...

Page 8: ...must meet the three minimum height requirements detailed in figure 8 A minimum draft of 0 05 w c measured in water column is required for proper drafting to prevent back puffing smoke spillage and to...

Page 9: ...ns Under extreme conditions it may rot instead of drying This point cannot be over stressed the vast majority of the problems related to the operation of a wood stove is caused by the fact that the wo...

Page 10: ...chemicals or waste in this appliance could result in damages to the heater or result in bodily injury It will also void any warranty on the appliance This heater is designed to burn natural wood only...

Page 11: ...seasoned wood Higher burn rates are not always the best heating burn rates after a good fire is established a lower burn rate may be a better option for efficient heating A lower burn rate slows the...

Page 12: ...ance overfiring is when any part of the appliance s exterior or chimney connections glow 5 Close the feed door and secure tightly 6 Adjust the air inlet control as described in the Fueling Instruction...

Page 13: ...ld up Ignition of creosote or overfiring could cause a chimney fire Chimney fires burn extremely hot and may ignite surrounding combustible materials In case of a chimney fire call the fire department...

Page 14: ...rom all combustible materials pending final disposal The ashes should be retained in the closed container until all cinders have thoroughly cooled SMOKE AND CO MONITORS Burning wood naturally produces...

Page 15: ...nspection 5 Replace new gasket starting at the bottom of glass working along edges being sure to center gasket channel on glass 6 Trim to length and butt ends together 7 Replace glass into door being...

Page 16: ...CORD NEAR OR ACROSS HOT SURFACES CAUTION THE BLOWER ASSEMBLY MUST BE DISCONNECTED FROM THE SOURCE OF ELECTRICAL SUPPLY BEFORE ATTEMPTING ANY MAINTENANCE MALE BLACK BLACK BLACK WHITE BLACK WHITE MALE B...

Page 17: ...2 3 12 11 IN ORDER TO MAINTAIN WARRANTY COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER USE OF THIRD PARTY COM...

Page 18: ...sket Clamp 1 13 29228 Bottom Glass Retainer 1 Key Part Description Qty 1 891414 Half Firebrick 2 2 89066 Firebrick 4 1 2 x 9 9 3 891989 2 Firebrick 1 1 4 x 2 1 4 1 4 893010 Half Firebrick Notched 1 5...

Page 19: ...19 Notes...

Page 20: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _______________...

Page 21: ...ult rieure Lors d une correspondance donnez toujours le num ro de mod le complet qui est inscrit sur la plaque attach e l appareil de chauffage Lors de la commande de pi ces de rechange donnez toujou...

Page 22: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Page 23: ...rieure 1 Cl Partie Description Qt 1 891414 Demi brique r fractaire 2 2 89066 Brique r fractaire 4 1 2 x 9 9 3 891989 2 Brique r fractaire 1 1 4 x 2 1 4 1 4 893010 Demi brique r fractaire entaill 1 5...

Page 24: ...4 611008 Cabinet droit 1 5 893261 Glissi re d amortisseur 1 6 29301 Accolade coulissante 2 7 893261 Manche en bois 1 8 29300 Couverture 1 9 29298 Amortisseur 1 10 611007 Cabinet gauche 1 10 1 13 8 15...

Page 25: ...u sur des surfaces chaudes Mise en garde Le ventilateur doit tre d connect de la source d alimentation lectrique avant de tenter toute op ration de maintenance M le Noire Noire Noire Blanche Noire Bla...

Page 26: ...r une tanch it correcte si les cordons deviennent effiloch s ou us s remplacez les tout de suite La porte ce cette unit utilise un joint de corde de 1 po de diam tre LE REMPLACEMENT DU CORDON D TANCHE...

Page 27: ...t naturellement des missions de fum e et du monoxyde de carbone CO Le CO est un gaz poison lorsque l exposition se fait des concentrations lev es pour une p riode de temps prolong e Bien que les syst...

Page 28: ...ance calorifique d passant les sp cifications de conception du chauffage peut lui causer des dommages permanents ainsi qu au catalyseur de postcombustion s il est pr sent 7 Videz les cendres r guli re...

Page 29: ...les b ches rouler et heurter la vitre REMARQUE Ne surchauffez pas l appareil une surchauffe se produit lorsqu une partie des connexions ext rieures ou de la chemin e de l appareil brille 5 Fermez la p...

Page 30: ...es meilleurs taux de combustion apr s qu un bon feu est tabli un taux de combustion plus bas peut tre la meilleure option pour un chauffage efficace Un taux de combustion plus bas ralentit la sortie d...

Page 31: ...aibles r sultent g n ralement lors de la combustion de bois durs s ch s s ch s l air par rapport aux r sineux ou aux bois durs verts ou fra chement coup s NE PAS BR LER 1 Des ordures 2 Coupures de gaz...

Page 32: ...m me pourrir au lieu de s cher On ne saurait trop soulign que la vaste majorit des probl mes li s au fonctionnement d un insert bois est caus e par le fait que le bois utilis tait trop humide ou avai...

Page 33: ...ges de dos les d versements de fum e et pour maximiser les performances Des jauges pour mesurer le tirage sont facilement disponibles dans les magasins de po les et sont conomiques louer ou acheter De...

Page 34: ...er l appareil Voir figure 7 pour la bonne orientation et le positionnement correct Installez en premier la rang e de briques situ e l arri re suivie par celle de chaque c t et enfin les briques r frac...

Page 35: ...quer et pr percer les trous n cessaires pour fixer l tiquette 7 Positionnez l appareil dans l ouverture du foyer jusqu ce que la l vre sup rieure de la chemise d air soit align e avec la fa ade du foy...

Page 36: ...e sommet de la chemin e est exig Un adaptateur en acier inoxydable est recommand pour attacher la gaine conduit d acier inoxydable la buse La partie m le ou ondul e de l adaptateur doit tre install e...

Page 37: ...doivent tre stock es pr cautionneusement si l appareil est d plac Le d montage de n importe quelle pi ce qui rend la chemin e inutilisable pour br ler des combustibles solides implique qu une tiquett...

Page 38: ...x sp cifications CAN ULC S635 Classe 3 norme pour les conduits existants de chemin es industrielles ou de ma onnerie ou CAN ULC S640 norme pour les conduits de nouvelles chemin es de ma onnerie 24 Sce...

Page 39: ...eautrepi ce unespaceconfin legrenier ou l int rieur d un b timent Ne connectez pas cet appareil un conduit de chemin e d j utilis par un autre appareil 10 NE connectez pas un appareil de chauffage au...

Page 40: ...les conditions d installation et les restrictions N utilisez pas cet appareil dans un mobile home une maison pr fabriqu e une caravane ou une tente U S Environmental Protection Agency Certifi pour se...

Reviews: