The maximum recommend vertical venting height is 12-

feet for 3-inch type “PL” vent. Total length of horizontal 

vent must not exceed 4-feet. This could cause back 

pressure. Use no more than 180 degrees of elbows (two 

90-degree elbows, or two 45-degree and one 90-degree 

elbow, etc.) to maintain adequate draft.

IMPORTANCE OF PROPER DRAFT

Draft is the force which moves air from the appliance 

up through the chimney. The amount of draft in your 

chimney depends on the length of the chimney, local 

geography, nearby obstructions and other factors. Too 

much draft may cause excessive temperatures in the 

appliance. Inadequate draft may cause backpuffing into 

the room and ‘plugging’ of the chimney. Inadequate draft 

will cause the appliance to leak smoke into the room 

through appliance and chimney connector joints. An 

uncontrollable burn or excessive temperature indicates 

excessive draft. Take into account the chimney’s location 

to ensure it is not too close to neighbours or in a valley 

which may cause unhealthy or nuisance conditions.

PELLET VENT TYPE

A certified 3-inch or 4-inch type “PL” pellet vent exhaust 

system must be used for installation and attached to the 

pipe connector provided on the back of the stove (use a 

3-inch to 4-inch adapter for 4-inch pipe). The connection 

at the back of the stove must be sealed using Hi-Temp 

RTV. Use a 4-inch vent if the vent height is over 12-

feet or if the installation is over 2,500 feet above sea 

level. We recommend the use of Simpson Dura-Vent® 

or Metal-Fab® pipe (if you use other pipes, consult your 

local building codes and/or building inspectors). Do not 

use Type-B Gas Vent pipe or galvanized pipe with this 

unit. The pellet vent pipe is designed to disassemble for 

cleaning and should be checked several times during the 

burning season. The pellet vent pipe is not furnished with 

the unit and must be purchased separately.

PELLET VENT INSTALLATION

The installation must include a clean-out tee to enable 

collection of fly ash and to permit periodic cleaning of the 

exhaust system. 90-degree elbows accumulate fly ash 

and soot thereby reducing exhaust flow and performance 

of the stove. Each elbow or tee reduces draft potential 

by 30% to 50%. All joints in the vent system must be 

fastened by at least 3 screws, and all joints must be 

sealed with Hi-Temp RTV silicone sealant to be airtight. 

The area where the vent pipe penetrates to the exterior of 

the home must be sealed with silicone or other means to 

maintain the vapor barrier between the exterior and the 

interior of the home. Vent surfaces can get hot enough 

to cause burns if touched by children. Noncombustible 

shielding or guards may be required.

PELLET VENT TERMINATION

Do not terminate the vent in an enclosed or semi-enclosed 

area, such as; carport, garage, attic, crawl space, under a 

sun deck or porch, narrow walkway, or any other location 

that can build up a concentration of fumes. Termination 

in one of these areas can also lead to unpredictable 

pressure situations with the appliance, and could result 

in improper performance and/or malfunction. The 

termination must exhaust above the outside air inlet 

elevation. The termination must not be located where it 

will become plugged by snow or other materials. Do not 

terminate the venting into an existing steel or masonry 

chimney.

VENT TERMINATION CLEARANCES

A.  Minimum 4-foot (1.22m) clearance below or beside 

any door or window that opens.

B.  Minimum 1-foot (0.3m) clearance above any door or 

window that opens.

C.  Minimum 3-foot (0.91m) clearance from any 

adjacent building.

D.  Minimum 7-foot (2.13m) clearance from any grade 

when adjacent to public walkways.

INSTALLATION

Summary of Contents for US5522

Page 1: ...re officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new...

Page 2: ...ons burning wood pellet fuel this heater has been shown to deliver heat at a rate of 13 640 to 32 591 Btu hr This heater achieved a particulate emissions rate of 1 5 g hr when tested to method ASTM E...

Page 3: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Page 4: ...ory installed wires out of the top of the stove There will be two wire harnesses as shown 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely 3 Connect the fa...

Page 5: ...nto the damper rod DOOR HANDLE INSTALLATION 1 Slide one of the provided washers onto the door handle rod 2 Next slide the wood handle onto the door handle rod 3 Slide the other provided washer onto th...

Page 6: ...TECTOR IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRON...

Page 7: ...6 153 mm on each side and 1 26 mm behind the stove Floor protection must extend under and 2 51 mm to each side of the chimney tee for an interior vertical installation A Floor Protector of 1 26 mm th...

Page 8: ...home transportable building with 8 GA copper wire using a serrated or star washer to penetrate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minim...

Page 9: ...ned to disassemble for cleaning and should be checked several times during the burning season The pellet vent pipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLAT...

Page 10: ...ause bodily harm heater damage and void your warranty HORIZONTAL EXHAUST VENT INSTALLATION 1 Locate your pellet stove in a location which meets the requirements of this manual but in an area where it...

Page 11: ...ves We recommend a 3ft 0 91m minimum vertical rise on the inside or outside of the house The through the wall installation is the least expensive and simplest installation Never terminate the end vent...

Page 12: ...AKE SURE TO KEEP IN MIND YOUR UNIT S CLEARANCE REQUIREMENTS 1 Mark the area and then cut the wall for vent installation if needed 2 Install the wall thimble as specified by the manufacturer wall thimb...

Page 13: ...at range 5 C C F Button The C F button changes the two digit display from degrees Celsius to degrees Fahrenheit D MODE M T BUTTON The Mode of the stove can be switched between manual and controlled wi...

Page 14: ...educed performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could res...

Page 15: ...ll minimize this Avoid placing items on the stovetop during this period because the paint could be affected Attempts to achieve heat output rates that exceed heater design specifications can result in...

Page 16: ...HEREFORE YOU SHOULD ALWAYS USE SOME TYPE OF HAND PROTECTION WHEN REFUELING YOUR STOVE DO NOT TOUCH THE HOT SURFACES OF THE STOVE EDUCATE ALL CHILDREN ON THE DANGERS OF A HIGH TEMPERATURE STOVE YOUNG C...

Page 17: ...move the clean outs and vacuum out any accumulated ash This should be done at least once per month or more frequently if large amounts of ash are noticed while cleaning or if the stove does not seem t...

Page 18: ...rush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally...

Page 19: ...gloves carefully remove any loose pieces of glass from the door frame 4 Replace the glass and gasket making sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eigh...

Page 20: ...himney venting for transportation of a transportable building The parts or materials to be employed for ember protectors and the minimum areas to be covered and their relation to the space heater as w...

Page 21: ...le The convection blower is overheating and tripping the internal temperature shutoff Clean any dust off of the windings and fan blade If oiling the blower does not help the blower may be bad The stov...

Page 22: ...es to the air switch Combustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should...

Page 23: ...move the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the l...

Page 24: ...secure connections Use a continuity tester to test the hopper safety switch replace if necessary The auger shaft is jammed Start by emptying the hopper Then remove the auger motor by removing the auge...

Page 25: ...The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that...

Page 26: ...in the hopper so that you can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing Next remove the two nuts that hol...

Page 27: ...ent type of wood softwood vs hardwood Different woods have different characteristics when being burned High Limit Switch Keeps Tripping Possible Causes Possible Remedies Unplug stove first when possib...

Page 28: ...28 2023 United States Stove Company WIRING DIAGRAM CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown...

Page 29: ...bly 1 5 80780 IR Remote 1 6 80455 High Temp Snapdisc 1 7 80886 Control Board 1 8 88351 Channel Gasket 1 9 88118 Ignitor Flange Gasket 1 10 80869 Ceramic Ignitor 1 Key Part Description Qty 11 80549 Pre...

Page 30: ..._____ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ________________________...

Page 31: ...____________________ Service de 07 Date ______________________ Nom de l ing nieur _________________________________ N de licence ______________________________________ Compagnie ______________________...

Page 32: ...80455 Snapdisc temp rature lev e 1 7 80886 Assy de carte de circuit imprim 1 8 88351 Joint de canal 1 9 88118 Joint de bride d igniteur 1 10 80869 Ignitor c ramique 1 Cl Partie Description Qt 11 8054...

Page 33: ...nited States Stove Company SCH MA DE C BLAGE CORRECT FAUX ASSUREZ VOUS QUE LES FILS SONT CONNECT S AUX DEUX BROCHES INF RIEURES DE L INTERRUPTEUR DE LA TR MIE COMME ILLUSTR 1 25A 250V Fusible 7 5A 250...

Page 34: ...NT La marque ou le lot de granul s utilis s est peut tre de mauvaise qualit Si possible essayez une autre marque de granul s Essayez aussi une marque compos e d un autre type de bois r sineux plut t q...

Page 35: ...Retirez le moteur de l arbre de la tari re et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coinc sur quelque chose Si le moteur ne tourne pas il est d fectueux Tari re bl...

Page 36: ...nt est d fectueux Le tableau de commande n envoie pas de courant l allumeur V rifiez la tension qui arrive l allumeur lors du d marrage Ce doit tre la tension nominale Si la tension est inf rieure la...

Page 37: ...u moteur de la tari re Utilisez un testeur de continuit pour tester l interrupteur de s curit de la tr mie remplacer le si n cessaire L arbre de la tari re est coinc Commencez par vider la tr mie Puis...

Page 38: ...par vider la tr mie Retirez ensuite le moteur de la tari re en retirant la goupille de la tari re puis retirez les deux boulons qui fixent le support de tari re au tube de tari re Vous pouvez maintena...

Page 39: ...eur de d bit d air Panne du ventilateur de combustion Lorsque le po le est en marche v rifiez si le ventilateur de combustion est en fonctionnement Sinon v rifiez l alimentation lectrique du ventilate...

Page 40: ...ble Le ventilateur de convection surchauffe et d clenche l arr t de temp rature interne Enlevez la poussi re des bobinages et pales de ventilateur Si le graissage du ventilateur ne suffit pas il se pe...

Page 41: ...ur le tampon de braises ne doit s tendre que jusqu la base du mur Un tampon de braises ne doit pas tre plac sur un tapis moins que le tampon ne soit structurellement soutenu pour emp cher le d placeme...

Page 42: ...rait 1 Une fois le radiateur refroidi retirez la porte du radiateur 2 Retirez le joint de corde de la porte puis les crous retenant le dispositif de retenue du verre en place 3 Tout en portant des gan...

Page 43: ...p cialement con ue pour le type de chemin e utilis Un ramoneur qualifi peut fournir ce service Il est galement conseill d inspecter de nettoyer et si n cessaire de r parer la totalit du syst me avant...

Page 44: ...mul es Cela devrait tre fait au moins une fois par mois ou plus fr quemment si de grandes quantit s de cendres sont remarqu es pendant le nettoyage ou si le po le ne semble pas br ler correctement Au...

Page 45: ...VOS MAINS LORS DU REMPLISSAGE DU PO LE NE TOUCHEZ PAS AUX SURFACES CHAUDES DU PO LE ENSEIGNEZ AUX ENFANTS LES DANGERS DES PO LES HAUTE TEMP RATURE LES JEUNES ENFANTS DOIVENT TRE SURVEILL S LORSQU ILS...

Page 46: ...tal Le maintien de petits incendies minimisera cela vitez de placer des articles sur la cuisini re pendant cette p riode car la peinture pourrait tre affect e Les tentatives pour atteindre des d bits...

Page 47: ...s Rangez vos pellets dans un endroit sec NE stockez PAS le carburant dans les d gagements d installation de l appareil ou dans l espace requis pour faire le plein et enlever les cendres Cela pourrait...

Page 48: ...production ou la plage de chaleur du po le Les niveaux de production de chaleur changent progressivement sur le diagramme en barres passant du niveau 1 au niveau 5 de chauffage C Touche C F La touche...

Page 49: ...us les codes du b timent locaux ou ragulations ayant comp tence avant de demander un installateur qualifi de proc der cette installation AVERTISSEMENT VOUS VOUDREZ PEUT TRE LOCALISER LES UTILITAIRES O...

Page 50: ...pour obtenir au dessus de la ligne de cong re Cette m me installation peut tre utilis e si votre chauffe eau est en dessous du niveau du sol en ajoutant simplement la section de nettoyage et tuyau ver...

Page 51: ...i pourrait causer des l sions corporelles les dommages de chauffage et annuler votre garantie ECHAPPEMENT HORIZONTALES INSTALLATION 1 Localisez votre po le granul s dans un endroit qui r pond aux exig...

Page 52: ...t tre achet s par ment INSTALLATION D VENT GRANUL S L installation doit comprendre un t de nettoyage pour permettre la collecte des cendres volantes et pour permettre le nettoyage p riodique du syst m...

Page 53: ...po PL et doit d passer d au moins 36 po 914 mm au dessus de la ligne de toit de la maisons mobiles b timents portatifs et doit tre install l aide d un coupe feu de plafond certifi et d un chapeau de...

Page 54: ...t tre suffisamment grand pour s tendre sur au moins 6 po 153 mm l avant 6 po 153 mm de chaque c t et 1 po 26 mm derri re le po le La protection du plancher doit s tendre sous et 2 po 51 mm de chaque c...

Page 55: ...RDON LECTRIQUE SOUS DEVANT OU SUR LE PO LE NE FAITES PAS COURIR LE CORDON LECTRIQUE DANS LES ZONES DE PASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTENTION ATTENTION LA COMBUSTION DU COMBUSTIBLE G N...

Page 56: ...re INSTALLATION DE LA POIGN E DE PORTE 1 Faites glisser l une des rondelles fournies sur la tige de la poign e de porte 2 Faites ensuite glisser la poign e en bois sur la tige de la poign e de porte 3...

Page 57: ...ll s en usine sur le dessus du po le Il y aura deux faisceaux de c bles comme illustr 2 D ballez les meilleurs contr les de montage et de veiller ce que le faisceau de c blage illustr est fix 3 Connec...

Page 58: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Page 59: ...x r el d alimentation en carburant et de br ler fois Taux d alimentation en carburant peut varier par autant que 20 Utiliser PFI carburant list pour de meilleurs r sultats Temps de combustion r glage...

Page 60: ...mpromis de fortune lors de l installation de ce radiateur Contactez les responsables locaux du b timent ou des pompiers pour conna tre les permis les restrictions et les exigences d installation dans...

Reviews: