background image

LOCATING THE HEATER

AS A LOCATION IS SELECTED,
KEEP THE FOLLOWING IN MIND:

1.  The chimney connection should be as short
as possible. The heater must have its own
chimney flue. Do not connect this unit to a
chimney flue serving another appliance. If there
is no chimney near where you wish to place the
heater, you can use a UL 103HT Residential
Type and Building Heating Appliance Chimney
(Fig. 5,6,6A,&6B).

2.  Place the heater on solid masonry or solid
concrete. When the heater is used on a com-
bustible floor protector of one layer of 3/8"
millboard having a thermal conductivity of
K=0.84 BTU in./ft. 2 hr. Deg. F with 28-gauge
sheet metal or a UL Listed floor protector. Have
the floor protector extend 16" beyond the door
side of the heater and under the connector pipe
in the back.

3.  Check Figures 2, 3, and 4. Be sure you have
the clearances shown from the heater and the
connector pipe to combustible surfaces. If you
have a SOLID brick or stone wall behind your
heater, you can place the heater as close as
you wish to the wall. If the wall is only faced with
brick or stone, treat it as a combustible wall.

4

21

Fig. 2

Fig. 4

17"

27"

16"

20"

54"

19 1/4"

36"

4 3/4"

NOTE: DASHED LINES SHOW
STRAIGHT UP AND THROUGH
THE WALL INSTALLATION

10"

32 1/4"

16"

FLOOR PROTECTOR
(TOP VIEW)

SIDEWALL

NON-COMBUSTIBLE
CONSTRUCTION IN
ACCORDANCE WITH
NFPA 211

12"

12"

Fig. 3

NOTE: BEFORE FIRING

HEATER

1. Remove plastic knob from

inside of cabinet door and

install on outside of door.

(See Page 15)

2.Slide firebricks toward the

rear so no gaps remain

between them.

CAUTION:

Keep furnishings and other

combustible materials away

from the heater.

STOP:  Before connecting

the flue pipe, check the
"SOLID FLUE DAMPER

INSTALLATION".

 (page 6)

F36 BLOWER KIT

An Optional Blower kit is available for the 2931 Wonderwood
automatic wood burning circulator heater.  If this kit is not available
where you have purchased this Wonderwood heater, you can
purchase the F36 Blower Kit directly from the factory.  To order
contact the United States Stove Company at the address and
telephone number given on the back page.

Summary of Contents for WONDERWOOD 2931

Page 1: ...TO ORDER REPAIR PARTS United States Stove Company 227 Industrial Park Rd P O Box 151 South Pittsburg TN 37380 423 837 2100 United States Stove Company 227 Industrial Park Rd P O Box 151 South Pittsbur...

Page 2: ...heet Metal Screws 6 Inside Diameter Underwriters Laboratories UL listed Residential Type and Building Heating Appliance Chimney Type HT or 6 existing Masonry Chimney with flue liner Floor Protector Ma...

Page 3: ...heater who is unfamiliar with the correct operation of the heater Do not allow children to use or in any way operate this heater Forfurtherinformationonusingyourheater safely obtain a copy of the Nati...

Page 4: ...k or stone wall behind your heater you can place the heater as close as you wish to the wall If the wall is only faced with brick or stone treat it as a combustible wall 4 21 Fig 2 Fig 4 17 27 16 20 5...

Page 5: ...22 00 Includes Shipping and Handling 1 4 20 Kep Nut Flue Collar Gasket Flue Collar 1 4 20x3 4 Bolt INSTALLING FLUE COLLAR This heater has been shipped with the flue collar unattached for shipping pur...

Page 6: ...aft Damper Hinge Pin 1 17200 5 Draft Damper Frame 1 40075 6 Draft Control Plate 1 23476 7 Clip 2 83818 8 Glass Brass Trim LH RH 2 89382 9 Glass Brass Trim TOP BOTTOM 2 89381 10 Glass Frame 1 68452 11...

Page 7: ...or each horizontal foot FIG 5 PIPE FLOOR PROTECTOR REFER TO CHIMNEY MANUFACTURERS PARTS AND INSTRUCTIONS 2 FT MIN 10 FT 3 FT MIN BAROMETRIC DRAFT CONTROL OPTIONAL 11 FT MIN CHIMNEY CAP MANDATORY PIPE...

Page 8: ...10 66440 Cabinet Back 1 11 68573 Cabinet Right Side 1 12 68236 Cabinet Door 1 13 89065 Door Hinge 1 14 21063 Back Brace 2 15 89062 Door Knob 1 16 83033 Machine Screw 8 32x1 4 1 17 83005 Machine Screw...

Page 9: ...petent mason certified Chim ney Sweep or knowledgeable inspec tor Many prefabricated fireplaces fall into the zero clearancefireplace category This is a factory metal fireplace with multi layeredconst...

Page 10: ...n plan carefully a high de gree of skill is required to insure safety An entry port for the stovepipe must be cut through the chimney with minimum damage to the fire clay liner Some involvedmeasuremen...

Page 11: ...a 6 diameter for optimum drafting but can function well with an 8 but becomes borderline beyond 8 diameter Masonrychimneysbuiltofconcreteblocks without flue liners of at least 5 8 fireclay do not mee...

Page 12: ...t the thermostat on High for maximum draft 2 Open the feed door and place paper and kindling on the grate for starting the fire 3 Light fire and close feed door 4 Add fuel after fire is burning briskl...

Reviews: