SAFETY NOTICE

In the unlikely event that your 2931 "overfires" (a condition evidenced by elbows,
stovepipes, and connectors glowing red in appearance or otherwise discoloring),
then your installation is subject to excessive draft created by either a chimney too tall
or too great in diameter in conjunction with its height, or some other factor of an
indeterminate cause. In this event, you should install a barometric draft regulator.
Such installation will preclude any overfiring and/or any hazardous consequences
of potential overfiring.

Barometric draft regulators are generally available where you purchased your stove
or may be ordered directly from United States Stove Company at a nominal charge.

BAROMETRIC DRAFT REGULATOR

Model DR6

1996 Consumer Price:

$22.00 - Includes Shipping and Handling

1/4-20 Kep Nut

Flue Collar Gasket

Flue Collar

1/4-20x3/4" Bolt

INSTALLING FLUE COLLAR

This heater has been shipped with the flue collar unattached for shipping purposes.
To install the flue collar simply follow the instructions below.

The following parts are necessary to install the flue collar:

1 - Flue collar
1 - Flue collar gasket
6 - 1/4-20x3/4" bolts
6 - 1/4-20 Kep nuts

1. Slide the flue collar gasket over the flue collar.
2. Place flue collar into the heaters firebox and thru the hole

in the back upper left hand corner.

3. Align the holes in the flue collar with those in the firebox.
4. Insert the (6) 1/4-20x3/4" Bolts thru the flue collar and
attach

the (6) 1/4-20 Kep nuts.

5. Tighten each Kep nut to ensure a good seal between the

flue collar and the firebox back.

NOTE:  The below drawing is an illustration to assist in the
installation of the flue collar.  The Feed door and Ash door
have been left off for viewing purposes only.

Summary of Contents for WONDERWOOD 2931

Page 1: ...TO ORDER REPAIR PARTS United States Stove Company 227 Industrial Park Rd P O Box 151 South Pittsburg TN 37380 423 837 2100 United States Stove Company 227 Industrial Park Rd P O Box 151 South Pittsbur...

Page 2: ...heet Metal Screws 6 Inside Diameter Underwriters Laboratories UL listed Residential Type and Building Heating Appliance Chimney Type HT or 6 existing Masonry Chimney with flue liner Floor Protector Ma...

Page 3: ...heater who is unfamiliar with the correct operation of the heater Do not allow children to use or in any way operate this heater Forfurtherinformationonusingyourheater safely obtain a copy of the Nati...

Page 4: ...k or stone wall behind your heater you can place the heater as close as you wish to the wall If the wall is only faced with brick or stone treat it as a combustible wall 4 21 Fig 2 Fig 4 17 27 16 20 5...

Page 5: ...22 00 Includes Shipping and Handling 1 4 20 Kep Nut Flue Collar Gasket Flue Collar 1 4 20x3 4 Bolt INSTALLING FLUE COLLAR This heater has been shipped with the flue collar unattached for shipping pur...

Page 6: ...aft Damper Hinge Pin 1 17200 5 Draft Damper Frame 1 40075 6 Draft Control Plate 1 23476 7 Clip 2 83818 8 Glass Brass Trim LH RH 2 89382 9 Glass Brass Trim TOP BOTTOM 2 89381 10 Glass Frame 1 68452 11...

Page 7: ...or each horizontal foot FIG 5 PIPE FLOOR PROTECTOR REFER TO CHIMNEY MANUFACTURERS PARTS AND INSTRUCTIONS 2 FT MIN 10 FT 3 FT MIN BAROMETRIC DRAFT CONTROL OPTIONAL 11 FT MIN CHIMNEY CAP MANDATORY PIPE...

Page 8: ...10 66440 Cabinet Back 1 11 68573 Cabinet Right Side 1 12 68236 Cabinet Door 1 13 89065 Door Hinge 1 14 21063 Back Brace 2 15 89062 Door Knob 1 16 83033 Machine Screw 8 32x1 4 1 17 83005 Machine Screw...

Page 9: ...petent mason certified Chim ney Sweep or knowledgeable inspec tor Many prefabricated fireplaces fall into the zero clearancefireplace category This is a factory metal fireplace with multi layeredconst...

Page 10: ...n plan carefully a high de gree of skill is required to insure safety An entry port for the stovepipe must be cut through the chimney with minimum damage to the fire clay liner Some involvedmeasuremen...

Page 11: ...a 6 diameter for optimum drafting but can function well with an 8 but becomes borderline beyond 8 diameter Masonrychimneysbuiltofconcreteblocks without flue liners of at least 5 8 fireclay do not mee...

Page 12: ...t the thermostat on High for maximum draft 2 Open the feed door and place paper and kindling on the grate for starting the fire 3 Light fire and close feed door 4 Add fuel after fire is burning briskl...

Reviews: