 of which is apparent: The chimney
provides a means for exhausting smoke
and flue gases resulting from combustion
of the fuel. Secondarily, though, the
chimney provides "Draft" which allows
oxygen to be continuously introduced
into the appliance, so that proper
combustion is possible. As of April 1,
1987, all heaters and furnaces
manufactured by United States Stove
Company should be installed using a
factory built chimney that meets the
"Type HT" requirement of UL 103 (when
a factory - built chimney is used).

IMPORTANT

*Size the chimney to the flue outlet on
the stove. (6" outlet = 6" I.D. chimney)
*Avoid using elbows except as
necessary (they reduce draft).
*Make sure all horizontal runs of con-
nector pipe go up hill (1/4" elevation for
each horizontal foot).

FIG. 5

PIPE

FLOOR PROTECTOR

REFER TO CHIMNEY
MANUFACTURERS PARTS
AND INSTRUCTIONS

2 FT MIN.

10 FT.

3 FT.
MIN.

BAROMETRIC
DRAFT CONTROL
(OPTIONAL)

11 FT. MIN.

CHIMNEY CAP MANDATORY

PIPE

FLOOR PROTECTOR

REFER TO CHIMNEY
MANUFACTURERS PARTS
AND INSTRUCTIONS

2 FT MIN.

10 FT.

3 FT.
MIN.

BAROMETRIC
DRAFT CONTROL
(OPTIONAL)

11 FT. MIN.

CHIMNEY CAP MANDATORY

FIG. 6
Cathedral Ceiling - Chimney
Cap Mandatory

CHIMNEY CONNECTION

Two basic types of chimneys are ap-
proved for use with solid fuel: Factory-
built and masonry. Factory-built chimney
must comply with UL103HT standard.

Do not expect your stove or furnace to
create draft. Draft is not a function of the
appliance. Draft is purely a function of
the chimney. Modern stoves and
furnaces are much more air-tight and
efficient than those of the past and,
therefore require greater draft. A
minimum of .05, measured in water
column (gauges to measure chimney
draft are readily available at stove shops
and are economical to purchase or rent)
is required for proper drafting to prevent
back-puffing, smoke spillage, and to
maximize performance.

Chimneys perform two functions - one

Summary of Contents for WONDERWOOD 2931

Page 1: ...TO ORDER REPAIR PARTS United States Stove Company 227 Industrial Park Rd P O Box 151 South Pittsburg TN 37380 423 837 2100 United States Stove Company 227 Industrial Park Rd P O Box 151 South Pittsbur...

Page 2: ...heet Metal Screws 6 Inside Diameter Underwriters Laboratories UL listed Residential Type and Building Heating Appliance Chimney Type HT or 6 existing Masonry Chimney with flue liner Floor Protector Ma...

Page 3: ...heater who is unfamiliar with the correct operation of the heater Do not allow children to use or in any way operate this heater Forfurtherinformationonusingyourheater safely obtain a copy of the Nati...

Page 4: ...k or stone wall behind your heater you can place the heater as close as you wish to the wall If the wall is only faced with brick or stone treat it as a combustible wall 4 21 Fig 2 Fig 4 17 27 16 20 5...

Page 5: ...22 00 Includes Shipping and Handling 1 4 20 Kep Nut Flue Collar Gasket Flue Collar 1 4 20x3 4 Bolt INSTALLING FLUE COLLAR This heater has been shipped with the flue collar unattached for shipping pur...

Page 6: ...aft Damper Hinge Pin 1 17200 5 Draft Damper Frame 1 40075 6 Draft Control Plate 1 23476 7 Clip 2 83818 8 Glass Brass Trim LH RH 2 89382 9 Glass Brass Trim TOP BOTTOM 2 89381 10 Glass Frame 1 68452 11...

Page 7: ...or each horizontal foot FIG 5 PIPE FLOOR PROTECTOR REFER TO CHIMNEY MANUFACTURERS PARTS AND INSTRUCTIONS 2 FT MIN 10 FT 3 FT MIN BAROMETRIC DRAFT CONTROL OPTIONAL 11 FT MIN CHIMNEY CAP MANDATORY PIPE...

Page 8: ...10 66440 Cabinet Back 1 11 68573 Cabinet Right Side 1 12 68236 Cabinet Door 1 13 89065 Door Hinge 1 14 21063 Back Brace 2 15 89062 Door Knob 1 16 83033 Machine Screw 8 32x1 4 1 17 83005 Machine Screw...

Page 9: ...petent mason certified Chim ney Sweep or knowledgeable inspec tor Many prefabricated fireplaces fall into the zero clearancefireplace category This is a factory metal fireplace with multi layeredconst...

Page 10: ...n plan carefully a high de gree of skill is required to insure safety An entry port for the stovepipe must be cut through the chimney with minimum damage to the fire clay liner Some involvedmeasuremen...

Page 11: ...a 6 diameter for optimum drafting but can function well with an 8 but becomes borderline beyond 8 diameter Masonrychimneysbuiltofconcreteblocks without flue liners of at least 5 8 fireclay do not mee...

Page 12: ...t the thermostat on High for maximum draft 2 Open the feed door and place paper and kindling on the grate for starting the fire 3 Light fire and close feed door 4 Add fuel after fire is burning briskl...