background image

9

16

18

15

1

2

17

6

3

5

16

10

19

13

12

9

7

4

8

14

11

REPAIR PARTS

AUTOMATIC WOOD BURNING CIRCULATOR HEATER

MODEL 2931 - EXTERIOR

14

CAUTION:

NOT ALL FIREPLACES

ARE SUITABLE FOR

INSTALLATION OF A WOOD

HEATER.

Many people may wish to convert an
existing fireplace to heater use. Usually,
safe connection of stovepipe to a ma-
sonry chimney requires more effort than
connection to a prefabricated chimney.
The fireplace must be closed and sealed
at the damper in the flue. Good sealants
are high temperature caulking, ceramic
wool, and furnace cement. Always re-
member to inspect the masonry chim-
ney and fireplace. If necessary, clean
the flue and smoke shelf before begin-
ning your installation. Install the heater
into the chimney so that the system can
be dismantled for cleaning and inspec-
tion.

Before deciding to convert your fire-
place or existing chimney, keep in mind
that older fireplaces and their chimneys
are unsafe. They must be structurally
sound, and the flue liner must be in good
condition. Do not use a chimney if it is
unlined (should have a tile clay liner
to protect brickwork), have it relined
professionally. 
Clearances to combus-
tibles are explained in the previous sec-
tion on masonry chimneys. If you have
any questions regarding the condition
of the chimney, consult a qualified engi-
neer, competent mason, certified Chim-
ney Sweep, or knowledgeable inspec-
tor.

Many prefabricated fireplaces fall into
the "zero-clearance fireplace" category.
This is a factory metal fireplace with
multi-layered construction. It is designed
to provide enough insulation and/or air
cooling so that the base, back and sides
can be safely placed in close contact
with combustible floors and walls. Al-
though many prefabricated fireplaces
have been tested by nationally recog-
nized organizations for use as fire-
places, they have not been tested to
accept heaters. In fact, their use as such
may void the manufacturer's warranty.

Steel-lined fireplaces, on the other
hand, can be used with heaters. These
units use a 1/4-inch fire box liner and an
air chamber in connection with 8 inches
of masonry to meet code. They contain
all the essential parts of a fireplace,
firebox, damper, throat, smoke shelf,
and smoke chamber. Many of them look
exactly like a masonry fireplace and
must be checked closely for above re-
quirements before installing a wood
heater into them.

Another method frequently used by
some people is to vent the heater di-
rectly into the fireplace. This does not
meet code since the heater is being
vented into another appliance - the
fireplace. This method should not be
attempted because combustion prod-
ucts will deposit and build up in the
firebox or fireplace. Be certain not to
install a hazard in you house. You will
void your warranty with this installa-
tion.

VENTING INTO A FIREPLACE
        (Not recommended)

Summary of Contents for WONDERWOOD 2931

Page 1: ...TO ORDER REPAIR PARTS United States Stove Company 227 Industrial Park Rd P O Box 151 South Pittsburg TN 37380 423 837 2100 United States Stove Company 227 Industrial Park Rd P O Box 151 South Pittsbur...

Page 2: ...heet Metal Screws 6 Inside Diameter Underwriters Laboratories UL listed Residential Type and Building Heating Appliance Chimney Type HT or 6 existing Masonry Chimney with flue liner Floor Protector Ma...

Page 3: ...heater who is unfamiliar with the correct operation of the heater Do not allow children to use or in any way operate this heater Forfurtherinformationonusingyourheater safely obtain a copy of the Nati...

Page 4: ...k or stone wall behind your heater you can place the heater as close as you wish to the wall If the wall is only faced with brick or stone treat it as a combustible wall 4 21 Fig 2 Fig 4 17 27 16 20 5...

Page 5: ...22 00 Includes Shipping and Handling 1 4 20 Kep Nut Flue Collar Gasket Flue Collar 1 4 20x3 4 Bolt INSTALLING FLUE COLLAR This heater has been shipped with the flue collar unattached for shipping pur...

Page 6: ...aft Damper Hinge Pin 1 17200 5 Draft Damper Frame 1 40075 6 Draft Control Plate 1 23476 7 Clip 2 83818 8 Glass Brass Trim LH RH 2 89382 9 Glass Brass Trim TOP BOTTOM 2 89381 10 Glass Frame 1 68452 11...

Page 7: ...or each horizontal foot FIG 5 PIPE FLOOR PROTECTOR REFER TO CHIMNEY MANUFACTURERS PARTS AND INSTRUCTIONS 2 FT MIN 10 FT 3 FT MIN BAROMETRIC DRAFT CONTROL OPTIONAL 11 FT MIN CHIMNEY CAP MANDATORY PIPE...

Page 8: ...10 66440 Cabinet Back 1 11 68573 Cabinet Right Side 1 12 68236 Cabinet Door 1 13 89065 Door Hinge 1 14 21063 Back Brace 2 15 89062 Door Knob 1 16 83033 Machine Screw 8 32x1 4 1 17 83005 Machine Screw...

Page 9: ...petent mason certified Chim ney Sweep or knowledgeable inspec tor Many prefabricated fireplaces fall into the zero clearancefireplace category This is a factory metal fireplace with multi layeredconst...

Page 10: ...n plan carefully a high de gree of skill is required to insure safety An entry port for the stovepipe must be cut through the chimney with minimum damage to the fire clay liner Some involvedmeasuremen...

Page 11: ...a 6 diameter for optimum drafting but can function well with an 8 but becomes borderline beyond 8 diameter Masonrychimneysbuiltofconcreteblocks without flue liners of at least 5 8 fireclay do not mee...

Page 12: ...t the thermostat on High for maximum draft 2 Open the feed door and place paper and kindling on the grate for starting the fire 3 Light fire and close feed door 4 Add fuel after fire is burning briskl...