This screen is similar to the
Media Data
screen shown in
Figure 4.8
. It contains information about the
compound such as type and amount used. Input the necessary information and press Enter
↵
to save
it. Press CONTINUE to proceed to the next screen.
Enter the maximum amount of parts per barrel and desired fill times for the water and media (
Figure
4.13
). These fill times will keep the process consistent by filling each barrel with the exact amount of
media every time. The media fill rate is a speed adjustment for the media pan feeder. This adjustment
is necessary to insure a steady flow with all media sizes and weights. An adjustment of the media flow
rate is needed when switching media and works in conjunction to the media fill time to deliver an
exact amount of media to the barrel. Once set, press Enter
↵
to save. Press CONTINUE to proceed to
the next screen.
NOTE: Standard water level is the height of the media; raise the water level 1 to 2 inches above the media for long or
aggressive processes. This will help to cool the contents of the barrel. To reduce part impingement, use a lower water level.