Troubleshooting
Problem
Solution
Water leaking at the top of the tank around the head.
You may need to turn the head to tighten it. The tank
head is pre-installed hand-tight, do not overtighten the
head (just turn it snug).
The tank leans to one side or is not level.
If the tank is not level, lift the tank straight up 6 inches
and tap it on the ground until the tank stands vertical.
The bottom of the tank is round and the boot allows the
tank to stand upright.
Water pressure is slowing.
It is recommended that the Sediment Filter be replaced
every 6-9 months depending on the amount of
sediment present in the water supply. If the system has
been working properly and the pressure is slowing, it
may be time to change the Sediment Filter. Check the
Sediment Filter and replace if necessary.
Water appears grey or cloudy.
Water may appear grey or cloudy for the first seven to
ten days after installation due to extra carbon dust.
Water pressure is slowing immediately after installation.
High flow rates such as bathtubs, utility sinks, hose
bibs, multi-headed showers, body sprayers, or anything
that is considered high flow for the first 72 hours should
be avoided. If you suspect a carbon blockage of the top
basket due to a high-flow situation within the first 72
hours of installation, turn off any running water for at
least 10 minutes. This will clear the blockage and you
can resume using water at low or normal flow rates.
Unlevel
Tank
Boot
Unlevel
Tank
Boot
Level
Tank
Unlevel
Boot
United Water Filter
WR
10/PS15
Premium Whole House Water Filter
/Conditioner
Rev A
Summary of Contents for PS15
Page 1: ...Owner s Manual Whole House Water Filter Conditioner Models WR10 PS15 ...
Page 16: ......
Page 18: ......
Page 20: ......