Basic - Information
Q3 240-840A
8
Sp
ec
ifi
at
io
n
2.5
Specifiation
Specification
Mains frequency
50 or 60Hz ±5%
Protection rating
IP 00
Format
VDE 0100 group C,
VDE 0160
Humidity rating
class F acc. to DIN 40040
Site of installation
< 1000m above sea level
Operating temperature range
0 ... 45°C
Extended operating temp. range
up to 60°C reduced by 2%/°C
Storage temperature range
-30°C to + 80°C
Current control loop circuit
Amplification
- input signal
0 to ± 10V=
- output
0 to ± 200% type current
Over-current limiting
10s 200% type current
Control precision
± 2%
Control range
1:50
Enable
> +10V
Speed control loop circuit (see manual REG)
Control precision (without actual value error)
< ±0.1%
Control range
> 1:1000
2.6
Interface
Interface control electronics X3
Function
Connector no.
+ 24V
±10%
X3: 1 and 2
+ 15V
±2%
X3: 3 and 4
- 24V
±10%
X3: 5 and 6
- 15V
±2%
X3: 7 and 8
Device GND
0
X3: 9, 10, 11, 12, 13, 14
I-command value
(GND)
0
X3: 15
I-command value (signal)
+10V=
X3: 16
Current controller enable
+10V=
X3: 17
Drive disable1
+10V=
X3: 18
Drive disable 2
+10V=
X3: 19
N (speed) actual
+10V=
X3: 20
I (current) actual
±5V=
X3: 21
Over-current power section
+10V=
X3: 22
Option UA
±10V=
X3: 23
Option UA
0 - +10V=
X3: 24
Drive ready BTB
+10V=
X3: 25
+5V
X3: 26