Crest Factor
specified from 10 mA rms (mA Range) or from 0,5 A rms (A Range) or from 20 V rms AC
(V Range), max. Peak voltage 850 mAss (mA Range) or 70 Ass (A Range) or max. Peak
Voltage 850 Vss
Range
Resolution
Accuracy
1,00...99,99
0,01
± 5 % rdg. ± 30 D
Frequency Measurement
specified from 10 mA rms (mA Range) or from 0,5 A rms (A Range) or from 20 V rms AC
(V Range)
Range
Resolution
Accuracy
45,0-65,0 Hz
0,1 Hz
± 0,2 Hz
65,0-999,9 Hz
0,1 Hz
± 0,1 % rdg. ± 0,2Hz
24 month Warranty
UNITEST instruments are subject to strict quality control. However, should the instrument
function improperly during daily use, your are protected by our 24 months warranty (valid
only with invoice).
We will repair free of charge any defects in workmanship or material, provided the instru-
ment is returned unopened and untampered with, i.e. with undamaged warranty label.
Any damage due to dropping or incorrect handling are not covered by the warranty.
If the instrument shows failure following expiration of warranty, our service department
can offer you a quick and economical repair.
BEHA reserves the right to make change.
17
PTDB93570002.qxd:Layout 1 30.05.2008 15:05 Uhr Seite