 I/O Expansion Modules  8 Inputs, 8 Outputs

 

 

The IO-DI8-TO8 and IO-DI8-TO8-L are I/O 
expansion modules that can be used in 
conjunction with specific Unitronics OPLC 
controllers. 
The modules are identical except for their 
voltage specifications: IO-DI8-TO8 runs at 
24 VDC; IO- DI8-TO8-L at 12 VDC. 
Both modules offer 8 digital inputs, type 
pnp/npn (source/sink), and 8 pnp (source) 
transistor outputs. 
The interface between a module and the 
OPLC is provided by an adapter. 
These modules may either be snap-
mounted on a DIN rail, or screw-mounted 
onto a mounting plate.

 

Component identification 

1 Module-to-module 

connector 

2 Status 

indicators 

Connection points for power  
supply to outputs 

Output connection points 

Module-to-module connector port 

Input connection points 

 

1

5

6

4

2

3

 

„

 

Before using this product, it is the responsibility of the user to read and understand this document and any 
accompanying documentation. 

„

 

All examples and diagrams shown herein are intended to aid understanding, and do not guarantee 
operation.  Unitronics accepts no responsibility for actual use of this product based on these examples. 

„

 

Please dispose of this product in accordance with local and national standards and regulations. 

„

 

Only qualified service personnel should open this device or carry out repairs. 

 

User safety and equipment protection guidelines 

This document is intended to aid trained and competent personnel in the installation of this equipment as 
defined by the European directives for machinery, low voltage, and EMC.  Only a technician or engineer trained 
in the local and national electrical standards should perform tasks associated with the device’s electrical wiring. 

Symbol Meaning 

Description 

 

Danger 

The identified danger causes physical 
and property damage. 

 

Warning 

The identified danger can cause 
physical and property damage. 

Symbols are used to highlight 
information relating to the user’s 
personal safety and equipment 
protection throughout this document.  
When these symbols appear, the 
associated information must be read 
carefully and understood fully. 

Caution

  

Caution Use 

caution. 

 

 

„

 

Failure to comply with appropriate safety guidelines can result in severe personal injury or 
property damage.  Always exercise proper caution when working with electrical equipment. 

Summary of Contents for IO-DI8-TO8

Page 1: ...rantee operation Unitronics accepts no responsibility for actual use of this product based on these examples Please dispose of this product in accordance with local and national standards and regulations Only qualified service personnel should open this device or carry out repairs User safety and equipment protection guidelines This document is intended to aid trained and competent personnel in th...

Page 2: ...corrosive or flammable gas moisture or rain excessive heat regular impact shocks or excessive vibration Leave a minimum of 10mm space for ventilation between the top and bottom edges of the device and the enclosure walls Do not place in water or let water leak onto the unit Do not allow debris to fall inside the unit during installation Mounting the Module DIN rail mounting Snap the device onto th...

Page 3: ...7 03 IO DI8 TO8 IO DI8 TO8 L I O Expansion Modules Unitronics Industrial Automation 3 4mm 5 8mm 0 228 85mm 3 346 80mm 3 15 68 4mm 2 693 93mm 3 66 4mm x2 0 16 0 16 ...

Page 4: ... Double check all wiring before turning on the power supply Wiring Procedures Use crimp terminals for wiring use 26 12 AWG wire 0 13 mm 2 3 31 mm 2 for all wiring purposes 1 Strip the wire to a length of 7 0 5mm 0 250 0 300 inches 2 Unscrew the terminal to its widest position before inserting a wire 3 Insert the wire completely into the terminal to ensure that a proper connection can be made 4 Tig...

Page 5: ...t High speed Counter 0V V High speed Counter Reset High speed Counter Wiring the Output s Power Supply Outputs Wiring DC supply 1 Connect the positive cable to the V0 terminal and the negative to the 0V terminal A non isolated power supply can be used provided that a 0V signal is connected to the chassis Do not connect the Neutral or Line signal of the 110 220VAC to the device s 0V pin In the even...

Page 6: ...nt 6mA 24VDC 6mA 12VDC Response time 10mSec typical Input 7 The specifications below apply when this input is wired for use as a high speed counter input frequency measurer See Notes 2 and 3 Resolution 16 bit Frequency 5kHz maximum Minimum pulse width 80µs Outputs Number of outputs 8 pnp source Output type P MOSFET open drain for both 24VDC and 12VDC outputs Galvanic isolation None Output current ...

Page 7: ...ules that are connected to an OPLC are assigned addresses that comprise a letter and a number The letter indicates whether the I O is an input I or an output O The number indicates the I O s location in the system This number relates to both the position of the expansion module in the system and to the position of the I O on that module Expansion modules are numbered from 0 7 as shown in the figur...

Page 8: ...earing in this document including but not limited to 0implied warranties of merchantability and or fitness for a particular use or purpose Unitronics assumes no responsibility for the results direct and or indirect of any misuse of the information appearing in this document nor for any use of the Unitronics products referred to herein in any manner deviating from the recommendations made in this d...