background image

 

 

JZ20-T40/JZ20-J-T40

 

 

Unitronics 

 

Add-on modules- 

 

Available by separate order for 
communication and cloning. 

Integral USB Port  

This may be used for 
programming purposes. 

Note:

 the USB port and an Add-on module cannot be physically connected at the same time. 

Add-on: during installation 

Add-on: after installation 

USB Port 

Installing an Add-on module requires sufficient clearance space 

 

72 mm (2.835")

 

27.5 mm
(1.083")

3

8

 m

m

(1

.4

9

6

")

3

5

.8

 m

m

(1

.4

0

9

")

 

 

  

DIN-rail mounting 

Snap PLC onto the DIN rail

 

Panel mounting 

Cut-out: 117 x 89mm (WxH) 
(4.606”x 3.504”) 

 

 

 

Note

: Removing the unit requires clearance space. Recommendation: approximately 40mm (1.58”). 

For UL listed module, in order to meet the UL508 standard, panel-mount this device on  
the flat surface of a Type 1 enclosure. 

Wiring 

Note:

 All diagrams are based on the rear view of the OPLC. 

 

  This equipment is designed to operate only in SELV/PELV/Class 2/Limited Power 

environments. 

  All power supplies in the system must include double insulation. Power supply outputs 

must be rated as SELV/PELV/Class 2/Limited Power. 

  Do not connect either the ‘Neutral or ‘Line’ signal of the 110/220VAC to device’s 0V pin. 

  Do not touch live wires. 

 

  All wiring activities should be performed while power is OFF. 

  Install an external circuit breaker. Guard against short-circuiting in external wiring. 

  Use appropriate circuit protection devices. 

  Unused pins should not be connected.  Ignoring this directive may damage the device. 

  Double-check all wiring before turning on the power supply. 

Caution

 

  To avoid damaging the wire, use a maximum torque of 0.5 N·m (5 kgf·cm). 

  Do not use tin, solder, or any substance on stripped wire that might cause the wire 

strand to break. 

  Install at maximum distance from high-voltage cables and power equipment. 

 

Summary of Contents for Jazz OPLC JZ20-T40

Page 1: ...ied service personnel should open this device or carry out repairs Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters that exceed permissible levels To avoid damaging the system do not connect disconnect the device when power is on Environmental Considerations Do not install in areas with excessive or co...

Page 2: ...agrams are based on the rear view of the OPLC This equipment is designed to operate only in SELV PELV Class 2 Limited Power environments All power supplies in the system must include double insulation Power supply outputs must be rated as SELV PELV Class 2 Limited Power Do not connect either the Neutral or Line signal of the 110 220VAC to device s 0V pin Do not touch live wires All wiring activiti...

Page 3: ...rail Allow for voltage drop and noise interference with input lines used over an extended distance Use wire that is properly sized for the load Earthing the JZ20 T40 JZ20 J T40 To maximize system performance avoid electromagnetic interference as follows Use a metal cabinet Connect the 0V terminal directly to the earth ground of the system Use the shortest less than 1m 3 3 ft and thickest 2 08mm 14...

Page 4: ... group as npn and the other as pnp or wire both groups as npn or as pnp In either case the n p pins must be connected Input wiring npn sink Input wiring pnp source Input wiring I0 I15 pnp source I16 I17 npn sink Digital Outputs Outputs Power Supply V01 is the power supply for outputs O0 O11 V02 is the power supply for outputs O12 O19 ...

Page 5: ...Shields should be connected at the signal source Analog Input wiring current AN0 AN1 2 or 3 wire 4 wire Analog Input wiring voltage AN2 AN3 Note If either I16 or I17 is wired as an npn digital input the remaining input may not be wired as an analog input ...

Page 6: ...mited to any implied warranties of merchantability fitness for a particular purpose or non infringement Unitronics assumes no responsibility for errors or omissions in the information presented in this document In no event shall Unitronics be liable for any special incidental indirect or consequential damages of any kind or any damages whatsoever arising out of or in connection with the use or per...

Reviews: