background image

 

Unitronics 

 

 

Jazz

™PLC+HMI  

Micro-PLC+HMI Installation Guide 

JZ20-T10/JZ20-J-T10

 

 

6 Digital Inputs including 2 HSC, 4 Transistor Outputs  

JZ20-T18/JZ20-J-T18 

 

6 Digital Inputs including 2 HSC, 2 Analog/Digital Inputs,  

2 Analog Inputs, 8 Transistor Outputs 

JZ20-J-T20HS 
 

 

6 Digital Inputs including 3 HSC/Shaft-encoder,  

2 Analog/Digital Inputs, 2 Analog Inputs,  

10 Transistor Outputs  

  Before using this product, the user must read and understand this document.  

  For additional information regarding this product, refer to the user guide and technical specifications. 

  All examples and diagrams are intended to aid understanding, and do not guarantee operation.  

Unitronics accepts no responsibility for actual use of this product based on these examples. 

  Please dispose of this product according to local and national standards and regulations. 

  Only qualified service personnel should open this device or carry out repairs. 

 

Failure to comply with appropriate safety guidelines can cause severe injury or property 
damage.  

 

  Do not attempt to use this device with parameters that exceed permissible levels. 

  To avoid damaging the system, do not connect/disconnect the device when power is on. 

Environmental Considerations 

 

  Do not install in areas with: excessive or conductive dust, corrosive or flammable gas,  

moisture or rain, excessive heat, regular impact shocks or excessive vibration. 

 

  Ventilation: 10mm space required between the PLC+HMI

s’ top/bottom edges & enclosure 

walls. 

  Do not place in water or let water leak onto the unit. 

  Do not allow debris to fall inside the unit during installation. 

 

Mounting 

Dimensions 

 

 

* Note that for JZ20-J modules those dimensions are 7.5 mm (0.295

”). 

 
 
 
 
 
 

Summary of Contents for JZ20-J-T20HS

Page 1: ...ese examples Please dispose of this product according to local and national standards and regulations Only qualified service personnel should open this device or carry out repairs Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters that exceed permissible levels To avoid damaging the system do not connect...

Page 2: ...oximately 40mm 1 58 For UL listed module in order to meet the UL508 standard panel mount this device on the flat surface of a Type 1 enclosure Wiring This equipment is designed to operate only in SELV PELV Class 2 Limited Power environments All power supplies in the system must include double insulation Power supply outputs must be rated as SELV PELV Class 2 Limited Power Do not connect either the...

Page 3: ...electromagnetic interference as follows Use a metal cabinet Connect the 0V terminal directly to the earth ground of the system Use the shortest less than 1m 3 3 ft and thickest 2 08mm 14AWG min wires possible Inputs 1 All the products comprise I0 I5 these digital inputs are arranged in a single group Via wiring the entire group may be set to either pnp or npn 2 The following information concerns J...

Page 4: ...s npn and the other as pnp or wire both groups as npn or as pnp In either case the n p pins must be connected Input wiring I0 I7 npn sink Input wiring I0 I7 pnp source Input wiring I0 I5 pnp source I6 I7 npn sink JZ20 J T20HS Note The inputs are arranged in two groups You can wire one group as npn and the other as pnp or wire both groups as npn or as pnp In either case the n p pins must be connect...

Page 5: ...T1X JZ20 J T1X JZ20 J T20HS 01 16 Unitronics 5 Input wiring I0 I5 pnp source I6 I7 npn sink HSC input wiring npn sink HSC input wiring pnp source Shaft encoder wiring npn sink Shaft encoder wiring pnp source ...

Page 6: ...of its products and to either permanently or temporarily withdraw any of the forgoing from the market All information in this document is provided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular purpose or non infringement Unitronics assumes no responsibility for errors or omissions in th...

Reviews: