background image

UniStream

®

   

Technical Specifications 
UAG-XKxxx, UAG-XKPxxx, 

UAG-CX-XKPxxx, UAG-CX-XKPLxxxx 

and UAG-XKPLxxxx 

This guide provides specifications for Unitronics’ Short Range and Long Range Local Expansion 

Adapter Kit for Uni-I/O™. 

All Kits comprise a Base unit, an End unit, and a connecting cable. The cable length varies 

according to kit model.  

 

Short-range adapter Kits 

Up to 3 meters 

 

Long-range adapter Kits 

3 meters and up 

Kits whose models contain the letter 'P' include a built-in power supply; a powered adapter module 

supports a greater number of I/O modules. 
There are two main classes of adapters:  

 

UAG-XK 

Both the Base and End units of these adapters have DIN-rail clips. You can: 

 

Snap the base onto the DIN-rail type structure on the back of UniStream Modular HMI  

 

Snap the base directly onto a UniStream PLC 

 

UAG-CX  

The base unit of these adapters has a plug; the end unit has DIN-rail clips. You can plug the 

base unit only into the I/O Expansion Jack offered by the UniStream Built-in series

 

Note that the maximum number of modules supported by a single controller is provided in the 

controller’s technical specifications. 

Technical specifications are available in the Unitronics Technical Library at 

www.unitronicsplc.com

. 

Adapter Models 
The ‘x’s in the model numbers are placeholders for the cable lengths.

 

 

Model 

Installation Options 

Integrated 

Power Supply 

Module Support 

UAG-XKxxx 

DIN-rail structure  
DIN-rail  

No 

8, includes any modules directly 

connected to a controller  

UAG-XKPxxx 

Yes 

16, in addition to any modules 

directly connected to a controller 

UAG-XKPLxxxx 

Yes 

UAG-CX-XKPxxx 

Plug into controller 

Jack 

Yes 

16 

UAG-CX-XKPLxxxx 

 

Power Supply 

 

Adapters without an integrated power supply: 

UniStream Modular and UniStream PLC controllers can supply power to a maximum of 8 modules. 

Adapters that do not have a power supply draw power from UniStream and supply it to the 

modules. This means, for example, that if there are 3 modules directly connected to the controller, 

you can add an additional 5 via this type of adapter. 

 

Adapters with integrated power supply: 

must be connected to a 24VDC power source. The adapter can then supply up to 16 modules with 

power, regardless of any directly connected to the controller. 

Installation Guides are available in the Unitronics Technical Library at 

www.unitronicsplc.com

. 

 

 

 

 

Unitronics 

 

 

Summary of Contents for UniStream UAG-XK Series

Page 1: ...er is provided in the controller s technical specifications Technical specifications are available in the Unitronics Technical Library at www unitronicsplc com Adapter Models The x s in the model numbers are placeholders for the cable lengths Model Installation Options Integrated Power Supply Module Support UAG XKxxx DIN rail structure DIN rail No 8 includes any modules directly connected to a con...

Page 2: ...KPL1200 1200cm 40 UAG CX XKPL1500 1500cm 50 UAG CX XKPL2000 2000cm 66 UAG CX XKPL3000 3000cm 98 UAG XKPL600 600cm 20 UAG XKPL1200 1200cm 40 UAG XKPL1500 1500cm 50 UAG XKPL2000 2000cm 66 UAG XKPL3000 3000cm 98 LED Indications Base Unit There are no LEDs in the Base Unit End Unit Green Output state Comment UAG XKxxx Link Off Cable is not connected or no power from the Base unit On Link has been esta...

Page 3: ... In order to connect a UniStream controller to more than one row of I O modules via Local I O Expansion adapters you must follow these rules UniStream Modular and UniStream PLC Up to 2 Short range adapters can be daisy chained to the controller or to any of the modules that are connected directly to the controller These may be either two UAG XKPxxxx that include an integrated power supply or one U...

Page 4: ...an be connected to a single UniStream controller using Uni I O modules and 5 Local I O Expansion adapters with power supplies Configurations with Short range adapter no Power Supply UAG XKxxxx If UAG XKxxxx is the only adapter connected to the controller the system can support up to 8 modules If a UAG XKxxxx follows another adapter with an integrated power supply the support capacity of that power...

Page 5: ...Expansion Adapter NOTE Each combination in the right table can be used with each combination in the left table They are independent of each other and the total number of I O modules that are supported is the sum of the two tables UniStream built in You must use the UAG CX XKPxxx or UAG CX XKPLxxx and it must be the adapter that is directly connected to the controller Optional configurations in the...

Page 6: ... XKPLxxxx Weight Base 65 g 0 14 lb End 142 g 0 31 lb Base 65 g 0 14 lb End 150 g 0 33 lb Base 64 g 0 14 lb End 92 g 0 2 lb Base 15 g 0 033 lb End 150 g 0 33 lb Base 15 g 0 14 lb End 92 g 0 2 lb Size Refer to the images below Base Unit UAG XKxxx UAG XKPxxx and UAG XKPLxxxx Top View Side View Front View Unitronics 6 ...

Page 7: ...UAG XKxxx UAG XKPxxx UAG CX XKPxxx UAG CX XKPLxxxx UAG XKPLxxxx Technical Specifications Base Unit UAG CX XKPxxx UAG CX XKPLxxxx Top View Front View Side View Unitronics 7 ...

Page 8: ...mplied including but not limited to any implied warranties of merchantability fitness for a particular purpose or non infringement Unitronics assumes no responsibility for errors or omissions in the information presented in this document In no event shall Unitronics be liable for any special incidental indirect or consequential damages of any kind or any damages whatsoever arising out of or in con...