Vision™ OPLC™ 

V130-33-B1 
Installation Guide 

 

The Unitronics V130-33-B1 offers the following features: 
I/O configurations can be added via Expansion Modules.  
Available by separate order: Ethernet, additional RS232/RS485, CANbus. 

General Description 

V130 OPLCs are micro-OPLCs, rugged programmable logic controllers that comprise:  

Built-in operating panel containing a 2.4” screen and a keypad 

Communications 

1 built-in serial port: RS232/RS485 

Optional—the user may order and install 
one or both of the following modules:  
- RS232/RS485/Ethernet  
- CANbus 

Communication Function Blocks include: 
SMS, GPRS, MODBUS serial/IP. Protocol 
FB enables PLC to communicate with 
almost any external device, via serial or 
Ethernet communications 

I/O Options 

V130 supports digital, high-speed, analog, 
weight and temperature measurement 
I/Os via: 

I/O Expansion Modules
Local or remote I/Os may be added 
via expansion port or CANbus.  

Information Mode 

This mode enables you to: 

View & Edit operand values, COM port settings, RTC and screen 
contrast/brightness settings 
Stop, initialize, and reset the PLC 

To enter Information Mode, press the <i> button for several seconds. 

Programming 
Software,  
& Utilities 

The Unitronics Setup CD contains VisiLogic software and other utilities. 

VisiLogic
Easily configure hardware and write both HMI and Ladder control 
applications; the Function Block library simplifies complex tasks 
such as PID. Write your application, and then download it to the 
controller via the programming cable included in the kit. 

Utilities
Includes UniOPC server, Remote Access for remote programming 
and diagnostics, and DataXport for run-time data logging. 

To learn how to use and program the controller, as well as use utilities such 
as Remote Access, refer to the VisiLogic Help system. 

Removable 
Memory Storage 

Micro SD card: store datalogs, Alarms, Trends, Data Tables; export to Excel; 
backup Ladder, HMI & OS and use this data to ‘clone’ PLCs. 

For more data, refer to the 

SD

 topics in the VisiLogic Help system. 

Data Tables 

Data tables enable you to set recipe parameters and create datalogs. 

 

Summary of Contents for Vision OPLC V130-33-B1

Page 1: ...his mode enables you to View Edit operand values COM port settings RTC and screen contrast brightness settings Stop initialize and reset the PLC To enter Information Mode press the i button for several seconds Programming Software Utilities The Unitronics Setup CD contains VisiLogic software and other utilities VisiLogic Easily configure hardware and write both HMI and Ladder control applications ...

Page 2: ...onics accepts no responsibility for actual use of this product based on these examples Please dispose of this product according to local and national standards and regulations Only qualified service personnel should open this device or carry out repairs Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters ...

Page 3: ...ller into the cut out ensuring that the rubber seal is in place 3 Push the 2 mounting brackets into their slots on the sides of the controller as shown in the figure to the right 4 Tighten the bracket screws against the panel Hold the bracket securely against the unit while tightening the screw 5 When properly mounted the controller is squarely situated in the panel cut out as shown in the figure ...

Page 4: ... kgf cm Do not use tin solder or any substance on stripped wire that might cause the wire strand to break Install at maximum distance from high voltage cables and power equipment Wiring Procedure Use crimp terminals for wiring use 26 12 AWG wire 0 13 mm 2 3 31 mm2 1 Strip the wire to a length of 7 0 5mm 0 250 0 300 inches 2 Unscrew the terminal to its widest position before inserting a wire 3 Inse...

Page 5: ...wer supply connect one end of a 14 AWG wire to the chassis signal connect the other end to the panel Note If possible the wire used to earth the power supply should not exceed 10 cm in length However it is recommended to earth the controller in all cases Communication Port Turn off power before making communications connections Caution Signals are related to the controller s 0V the same 0V is used...

Page 6: ...gnal 4 RS232 signal 5 0V reference 5 RS232 signal 6 DSR signal 6 B signal Pin 1 Standard programming cables do not provide connection points for pins 1 and 6 When a port is adapted to RS485 Pin 1 DTR is used for signal A and Pin 6 DSR signal is used for signal B RS232 to RS485 Jumper Settings The figure to the right shows the jumper factory default settings RS232 RS485 termination ON Note that in ...

Page 7: ...ntroller 1 Gently replace the board Make certain that the pins fit correctly into their matching receptacle Do not force the board into place doing so may damage the controller 2 Replace the back cover of the controller and fasten the corner screws Note You must replace the back cover securely before powering up the controller Samara tel 7 846 273 95 85 samara klinkmann spb ru Yekaterinburg tel 7 ...